Loading…

Flow injection spectrophotometric determination of lactic acid in skimmed milk based on a photochemical reaction

A spectrophotometric method for the determination of lactic acid in milk samples based on the use of a photochemical reaction carried out in a Flow Injection System is proposed. Determination is based on the reaction between lactic acid and Fe(III), which is reduced to Fe(II) in the presence of UV l...

Full description

Saved in:
Bibliographic Details
Published in:Talanta (Oxford) 1999-08, Vol.50 (1), p.121-131
Main Authors: Gómez-Álvarez, E., Luque-Pérez, E., Rı́os, A., Valcárcel, M.
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c392t-e3304bc10187707149b8afddaf292eb4115a690a28a8180ce33005ec7af6ba913
cites
container_end_page 131
container_issue 1
container_start_page 121
container_title Talanta (Oxford)
container_volume 50
creator Gómez-Álvarez, E.
Luque-Pérez, E.
Rı́os, A.
Valcárcel, M.
description A spectrophotometric method for the determination of lactic acid in milk samples based on the use of a photochemical reaction carried out in a Flow Injection System is proposed. Determination is based on the reaction between lactic acid and Fe(III), which is reduced to Fe(II) in the presence of UV light, being the latter made to react with o-phenanthroline. The complex formed between Fe(II) and o-phenanthroline, Fe( o-phen) 3 2+ (ferroin) is a coloured compound and it can be spectrophotometrically monitored at 512 nm. The method shows a linear range between 0.5 and 50 μg ml −1 with a limit of detection of 0.16 μg ml −1. The precision was ±2.15 expressed as relative standard deviation ( n=11) and the sample throughput of 30 samples h −1. Also non-linear adjustments have been made and validated by ANOVA. The proposed method has been applied to the determination of lactic acid in both synthetic and milk samples.
doi_str_mv 10.1016/S0039-9140(99)00112-5
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1727654173</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0039914099001125</els_id><sourcerecordid>1727654173</sourcerecordid><originalsourceid>FETCH-LOGICAL-c392t-e3304bc10187707149b8afddaf292eb4115a690a28a8180ce33005ec7af6ba913</originalsourceid><addsrcrecordid>eNqFkU1P3DAQhq0KVLa0P6GVDxzoITCOkzg-oQoBrYTEgfZsTZyJ1pDEwc5S8e_xZlfdY0-ew_POx2PGvgq4ECCqy0cAqTMtCjjX-juAEHlWfmArUSuZyVLJI7b6h5ywTzE-AUAuQX5kJ6LWlVKQr9h02_u_3I1PZGfnRx6nVAQ_rf3sB5qDs7ylmcLgRlwA3_EeE2s5WtemJI_Pbhio5YPrn3mDMZWJQ770sGsanMWeB8Jlwmd23GEf6cv-PWV_bm9-X__M7h_ufl3_uM-s1PmckZRQNDadWqdFlSh0U2PXttjlOqemEKLESgPmNdaiBrvloSSrsKsa1EKesvNd3yn4lw3F2QwuWup7HMlvohEqV1VZCCUTWu5QG3yMgTozBTdgeDMCzFa2WWSbrUmjtVlkmzLlvu1HbJok4JDa203A2R7AmBx0AUfr4oHTJch6i13tMEo-Xh0FE62j0VLrQvoN03r3n03eAaYPnIw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1727654173</pqid></control><display><type>article</type><title>Flow injection spectrophotometric determination of lactic acid in skimmed milk based on a photochemical reaction</title><source>ScienceDirect Journals</source><creator>Gómez-Álvarez, E. ; Luque-Pérez, E. ; Rı́os, A. ; Valcárcel, M.</creator><creatorcontrib>Gómez-Álvarez, E. ; Luque-Pérez, E. ; Rı́os, A. ; Valcárcel, M.</creatorcontrib><description>A spectrophotometric method for the determination of lactic acid in milk samples based on the use of a photochemical reaction carried out in a Flow Injection System is proposed. Determination is based on the reaction between lactic acid and Fe(III), which is reduced to Fe(II) in the presence of UV light, being the latter made to react with o-phenanthroline. The complex formed between Fe(II) and o-phenanthroline, Fe( o-phen) 3 2+ (ferroin) is a coloured compound and it can be spectrophotometrically monitored at 512 nm. The method shows a linear range between 0.5 and 50 μg ml −1 with a limit of detection of 0.16 μg ml −1. The precision was ±2.15 expressed as relative standard deviation ( n=11) and the sample throughput of 30 samples h −1. Also non-linear adjustments have been made and validated by ANOVA. The proposed method has been applied to the determination of lactic acid in both synthetic and milk samples.</description><identifier>ISSN: 0039-9140</identifier><identifier>EISSN: 1873-3573</identifier><identifier>DOI: 10.1016/S0039-9140(99)00112-5</identifier><identifier>PMID: 18967702</identifier><identifier>CODEN: TLNTA2</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Biological and medical sciences ; Flow injection ; Food industries ; Fundamental and applied biological sciences. Psychology ; Lactic acid ; Milk and cheese industries. Ice creams ; Milk samples ; Photochemical reaction</subject><ispartof>Talanta (Oxford), 1999-08, Vol.50 (1), p.121-131</ispartof><rights>1999 Elsevier Science B.V.</rights><rights>1999 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c392t-e3304bc10187707149b8afddaf292eb4115a690a28a8180ce33005ec7af6ba913</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=1950382$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/18967702$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Gómez-Álvarez, E.</creatorcontrib><creatorcontrib>Luque-Pérez, E.</creatorcontrib><creatorcontrib>Rı́os, A.</creatorcontrib><creatorcontrib>Valcárcel, M.</creatorcontrib><title>Flow injection spectrophotometric determination of lactic acid in skimmed milk based on a photochemical reaction</title><title>Talanta (Oxford)</title><addtitle>Talanta</addtitle><description>A spectrophotometric method for the determination of lactic acid in milk samples based on the use of a photochemical reaction carried out in a Flow Injection System is proposed. Determination is based on the reaction between lactic acid and Fe(III), which is reduced to Fe(II) in the presence of UV light, being the latter made to react with o-phenanthroline. The complex formed between Fe(II) and o-phenanthroline, Fe( o-phen) 3 2+ (ferroin) is a coloured compound and it can be spectrophotometrically monitored at 512 nm. The method shows a linear range between 0.5 and 50 μg ml −1 with a limit of detection of 0.16 μg ml −1. The precision was ±2.15 expressed as relative standard deviation ( n=11) and the sample throughput of 30 samples h −1. Also non-linear adjustments have been made and validated by ANOVA. The proposed method has been applied to the determination of lactic acid in both synthetic and milk samples.</description><subject>Biological and medical sciences</subject><subject>Flow injection</subject><subject>Food industries</subject><subject>Fundamental and applied biological sciences. Psychology</subject><subject>Lactic acid</subject><subject>Milk and cheese industries. Ice creams</subject><subject>Milk samples</subject><subject>Photochemical reaction</subject><issn>0039-9140</issn><issn>1873-3573</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1999</creationdate><recordtype>article</recordtype><recordid>eNqFkU1P3DAQhq0KVLa0P6GVDxzoITCOkzg-oQoBrYTEgfZsTZyJ1pDEwc5S8e_xZlfdY0-ew_POx2PGvgq4ECCqy0cAqTMtCjjX-juAEHlWfmArUSuZyVLJI7b6h5ywTzE-AUAuQX5kJ6LWlVKQr9h02_u_3I1PZGfnRx6nVAQ_rf3sB5qDs7ylmcLgRlwA3_EeE2s5WtemJI_Pbhio5YPrn3mDMZWJQ770sGsanMWeB8Jlwmd23GEf6cv-PWV_bm9-X__M7h_ufl3_uM-s1PmckZRQNDadWqdFlSh0U2PXttjlOqemEKLESgPmNdaiBrvloSSrsKsa1EKesvNd3yn4lw3F2QwuWup7HMlvohEqV1VZCCUTWu5QG3yMgTozBTdgeDMCzFa2WWSbrUmjtVlkmzLlvu1HbJok4JDa203A2R7AmBx0AUfr4oHTJch6i13tMEo-Xh0FE62j0VLrQvoN03r3n03eAaYPnIw</recordid><startdate>19990823</startdate><enddate>19990823</enddate><creator>Gómez-Álvarez, E.</creator><creator>Luque-Pérez, E.</creator><creator>Rı́os, A.</creator><creator>Valcárcel, M.</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>IQODW</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19990823</creationdate><title>Flow injection spectrophotometric determination of lactic acid in skimmed milk based on a photochemical reaction</title><author>Gómez-Álvarez, E. ; Luque-Pérez, E. ; Rı́os, A. ; Valcárcel, M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c392t-e3304bc10187707149b8afddaf292eb4115a690a28a8180ce33005ec7af6ba913</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1999</creationdate><topic>Biological and medical sciences</topic><topic>Flow injection</topic><topic>Food industries</topic><topic>Fundamental and applied biological sciences. Psychology</topic><topic>Lactic acid</topic><topic>Milk and cheese industries. Ice creams</topic><topic>Milk samples</topic><topic>Photochemical reaction</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Gómez-Álvarez, E.</creatorcontrib><creatorcontrib>Luque-Pérez, E.</creatorcontrib><creatorcontrib>Rı́os, A.</creatorcontrib><creatorcontrib>Valcárcel, M.</creatorcontrib><collection>Pascal-Francis</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Talanta (Oxford)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gómez-Álvarez, E.</au><au>Luque-Pérez, E.</au><au>Rı́os, A.</au><au>Valcárcel, M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Flow injection spectrophotometric determination of lactic acid in skimmed milk based on a photochemical reaction</atitle><jtitle>Talanta (Oxford)</jtitle><addtitle>Talanta</addtitle><date>1999-08-23</date><risdate>1999</risdate><volume>50</volume><issue>1</issue><spage>121</spage><epage>131</epage><pages>121-131</pages><issn>0039-9140</issn><eissn>1873-3573</eissn><coden>TLNTA2</coden><abstract>A spectrophotometric method for the determination of lactic acid in milk samples based on the use of a photochemical reaction carried out in a Flow Injection System is proposed. Determination is based on the reaction between lactic acid and Fe(III), which is reduced to Fe(II) in the presence of UV light, being the latter made to react with o-phenanthroline. The complex formed between Fe(II) and o-phenanthroline, Fe( o-phen) 3 2+ (ferroin) is a coloured compound and it can be spectrophotometrically monitored at 512 nm. The method shows a linear range between 0.5 and 50 μg ml −1 with a limit of detection of 0.16 μg ml −1. The precision was ±2.15 expressed as relative standard deviation ( n=11) and the sample throughput of 30 samples h −1. Also non-linear adjustments have been made and validated by ANOVA. The proposed method has been applied to the determination of lactic acid in both synthetic and milk samples.</abstract><cop>Amsterdam</cop><cop>Oxford</cop><pub>Elsevier B.V</pub><pmid>18967702</pmid><doi>10.1016/S0039-9140(99)00112-5</doi><tpages>11</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0039-9140
ispartof Talanta (Oxford), 1999-08, Vol.50 (1), p.121-131
issn 0039-9140
1873-3573
language eng
recordid cdi_proquest_miscellaneous_1727654173
source ScienceDirect Journals
subjects Biological and medical sciences
Flow injection
Food industries
Fundamental and applied biological sciences. Psychology
Lactic acid
Milk and cheese industries. Ice creams
Milk samples
Photochemical reaction
title Flow injection spectrophotometric determination of lactic acid in skimmed milk based on a photochemical reaction
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T02%3A03%3A46IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Flow%20injection%20spectrophotometric%20determination%20of%20lactic%20acid%20in%20skimmed%20milk%20based%20on%20a%20photochemical%20reaction&rft.jtitle=Talanta%20(Oxford)&rft.au=G%C3%B3mez-%C3%81lvarez,%20E.&rft.date=1999-08-23&rft.volume=50&rft.issue=1&rft.spage=121&rft.epage=131&rft.pages=121-131&rft.issn=0039-9140&rft.eissn=1873-3573&rft.coden=TLNTA2&rft_id=info:doi/10.1016/S0039-9140(99)00112-5&rft_dat=%3Cproquest_cross%3E1727654173%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c392t-e3304bc10187707149b8afddaf292eb4115a690a28a8180ce33005ec7af6ba913%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1727654173&rft_id=info:pmid/18967702&rfr_iscdi=true