Loading…

On the determination of the kinetic parameters for the BOD test

One of the most common tests for the determination of the organic content of wastewater is the biochemical oxygen demand (BOD). The kinetic parameters k (rate constant) and L (ultimate demand) can be estimated by different methods, such as: non-linear fitting, linear fitting of modified expressions...

Full description

Saved in:
Bibliographic Details
Published in:Water S. A. 1999-07, Vol.25 (3), p.377-379
Main Authors: CUTRERA, G, MANFREDI, L, DEL VALLE, C. E, GONZALEZ, J. F
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 379
container_issue 3
container_start_page 377
container_title Water S. A.
container_volume 25
creator CUTRERA, G
MANFREDI, L
DEL VALLE, C. E
GONZALEZ, J. F
description One of the most common tests for the determination of the organic content of wastewater is the biochemical oxygen demand (BOD). The kinetic parameters k (rate constant) and L (ultimate demand) can be estimated by different methods, such as: non-linear fitting, linear fitting of modified expressions of the BOD equation, and the Thomas method among others. In this note, three of the most common methods for the determination of k and L are compared. Particular attention is paid to the accuracy of each method.
format article
fullrecord <record><control><sourceid>proquest_pasca</sourceid><recordid>TN_cdi_proquest_miscellaneous_17284792</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>17284792</sourcerecordid><originalsourceid>FETCH-LOGICAL-p213t-b36d6881005b0e6b0965b903a130964bf2e0d71af65837418aa2d8f5318adabf3</originalsourceid><addsrcrecordid>eNotjT1PwzAYhD2A1FL6Hzwgtki23yS2JwTlo0iVssAcvU5sYUicYLsD_55QOt3p7tHdBVkzkKooJagVuUrpkzEBUOo1uWsCzR-W9jbbOPqA2U-BTu4Ufvlgs-_ojBHHPyBRN8VT9dA80mxTviaXDodkt2fdkPfnp7fdvjg0L6-7-0MxCw65MFD3tVKcscowWxum68poBshhsaVxwrJecnR1pUCWXCGKXrkKFtejcbAht_-7c5y-j8txO_rU2WHAYKdjarkUqpRaLODNGcTU4eAihs6ndo5-xPjTcg2cSw2_hBVRFA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>17284792</pqid></control><display><type>article</type><title>On the determination of the kinetic parameters for the BOD test</title><source>Full-Text Journals in Chemistry (Open access)</source><creator>CUTRERA, G ; MANFREDI, L ; DEL VALLE, C. E ; GONZALEZ, J. F</creator><creatorcontrib>CUTRERA, G ; MANFREDI, L ; DEL VALLE, C. E ; GONZALEZ, J. F</creatorcontrib><description>One of the most common tests for the determination of the organic content of wastewater is the biochemical oxygen demand (BOD). The kinetic parameters k (rate constant) and L (ultimate demand) can be estimated by different methods, such as: non-linear fitting, linear fitting of modified expressions of the BOD equation, and the Thomas method among others. In this note, three of the most common methods for the determination of k and L are compared. Particular attention is paid to the accuracy of each method.</description><identifier>ISSN: 0378-4738</identifier><identifier>CODEN: WASADV</identifier><language>eng</language><publisher>Pretoria: Water Research Commision</publisher><subject>Applied sciences ; Exact sciences and technology ; Pollution ; Wastewaters ; Water treatment and pollution</subject><ispartof>Water S. A., 1999-07, Vol.25 (3), p.377-379</ispartof><rights>1999 INIST-CNRS</rights><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=1931179$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>CUTRERA, G</creatorcontrib><creatorcontrib>MANFREDI, L</creatorcontrib><creatorcontrib>DEL VALLE, C. E</creatorcontrib><creatorcontrib>GONZALEZ, J. F</creatorcontrib><title>On the determination of the kinetic parameters for the BOD test</title><title>Water S. A.</title><description>One of the most common tests for the determination of the organic content of wastewater is the biochemical oxygen demand (BOD). The kinetic parameters k (rate constant) and L (ultimate demand) can be estimated by different methods, such as: non-linear fitting, linear fitting of modified expressions of the BOD equation, and the Thomas method among others. In this note, three of the most common methods for the determination of k and L are compared. Particular attention is paid to the accuracy of each method.</description><subject>Applied sciences</subject><subject>Exact sciences and technology</subject><subject>Pollution</subject><subject>Wastewaters</subject><subject>Water treatment and pollution</subject><issn>0378-4738</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1999</creationdate><recordtype>article</recordtype><recordid>eNotjT1PwzAYhD2A1FL6Hzwgtki23yS2JwTlo0iVssAcvU5sYUicYLsD_55QOt3p7tHdBVkzkKooJagVuUrpkzEBUOo1uWsCzR-W9jbbOPqA2U-BTu4Ufvlgs-_ojBHHPyBRN8VT9dA80mxTviaXDodkt2fdkPfnp7fdvjg0L6-7-0MxCw65MFD3tVKcscowWxum68poBshhsaVxwrJecnR1pUCWXCGKXrkKFtejcbAht_-7c5y-j8txO_rU2WHAYKdjarkUqpRaLODNGcTU4eAihs6ndo5-xPjTcg2cSw2_hBVRFA</recordid><startdate>19990701</startdate><enddate>19990701</enddate><creator>CUTRERA, G</creator><creator>MANFREDI, L</creator><creator>DEL VALLE, C. E</creator><creator>GONZALEZ, J. F</creator><general>Water Research Commision</general><scope>IQODW</scope><scope>7UA</scope><scope>C1K</scope></search><sort><creationdate>19990701</creationdate><title>On the determination of the kinetic parameters for the BOD test</title><author>CUTRERA, G ; MANFREDI, L ; DEL VALLE, C. E ; GONZALEZ, J. F</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p213t-b36d6881005b0e6b0965b903a130964bf2e0d71af65837418aa2d8f5318adabf3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1999</creationdate><topic>Applied sciences</topic><topic>Exact sciences and technology</topic><topic>Pollution</topic><topic>Wastewaters</topic><topic>Water treatment and pollution</topic><toplevel>online_resources</toplevel><creatorcontrib>CUTRERA, G</creatorcontrib><creatorcontrib>MANFREDI, L</creatorcontrib><creatorcontrib>DEL VALLE, C. E</creatorcontrib><creatorcontrib>GONZALEZ, J. F</creatorcontrib><collection>Pascal-Francis</collection><collection>Water Resources Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><jtitle>Water S. A.</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>CUTRERA, G</au><au>MANFREDI, L</au><au>DEL VALLE, C. E</au><au>GONZALEZ, J. F</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>On the determination of the kinetic parameters for the BOD test</atitle><jtitle>Water S. A.</jtitle><date>1999-07-01</date><risdate>1999</risdate><volume>25</volume><issue>3</issue><spage>377</spage><epage>379</epage><pages>377-379</pages><issn>0378-4738</issn><coden>WASADV</coden><abstract>One of the most common tests for the determination of the organic content of wastewater is the biochemical oxygen demand (BOD). The kinetic parameters k (rate constant) and L (ultimate demand) can be estimated by different methods, such as: non-linear fitting, linear fitting of modified expressions of the BOD equation, and the Thomas method among others. In this note, three of the most common methods for the determination of k and L are compared. Particular attention is paid to the accuracy of each method.</abstract><cop>Pretoria</cop><pub>Water Research Commision</pub><tpages>3</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0378-4738
ispartof Water S. A., 1999-07, Vol.25 (3), p.377-379
issn 0378-4738
language eng
recordid cdi_proquest_miscellaneous_17284792
source Full-Text Journals in Chemistry (Open access)
subjects Applied sciences
Exact sciences and technology
Pollution
Wastewaters
Water treatment and pollution
title On the determination of the kinetic parameters for the BOD test
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-03T14%3A18%3A26IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pasca&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=On%20the%20determination%20of%20the%20kinetic%20parameters%20for%20the%20BOD%20test&rft.jtitle=Water%20S.%20A.&rft.au=CUTRERA,%20G&rft.date=1999-07-01&rft.volume=25&rft.issue=3&rft.spage=377&rft.epage=379&rft.pages=377-379&rft.issn=0378-4738&rft.coden=WASADV&rft_id=info:doi/&rft_dat=%3Cproquest_pasca%3E17284792%3C/proquest_pasca%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-p213t-b36d6881005b0e6b0965b903a130964bf2e0d71af65837418aa2d8f5318adabf3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=17284792&rft_id=info:pmid/&rfr_iscdi=true