Loading…
Quantitative Analysis of Corneal Energy Dissipation and Corneal and Orbital Deformation in Response to an Air-Pulse in Healthy Eyes
To examine and evaluate ocular biomechanical metrics and additionally derived corneal and orbital components using a noncontact Scheimpflug-based tonometer (CorVis ST) in a population of healthy eyes. A total of 152 eyes of 152 participants were examined by slit-lamp biomicroscopy, corneal tomograph...
Saved in:
Published in: | Investigative ophthalmology & visual science 2015-10, Vol.56 (11), p.6941-6947 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | To examine and evaluate ocular biomechanical metrics and additionally derived corneal and orbital components using a noncontact Scheimpflug-based tonometer (CorVis ST) in a population of healthy eyes.
A total of 152 eyes of 152 participants were examined by slit-lamp biomicroscopy, corneal tomography, and the CorVis ST (CST). This determined the distribution of outputs from the CST, such as deformation amplitude (DA), and additionally derived parameters, including maximum corneal deformation (MCD), maximum orbital deformation (MOD), and corneal energy dissipation (CED).
The mean age of participants was 35.88 ± 13.8 years. Deformation amplitude significantly correlated with age (r = 0.24, P = 0.002) but not sex or ethnicity (P > 0.05). Multiple linear regression analysis revealed significant correlations between DA and age (r = 0.19, P = 0.006) and DA and IOP (r = -0.59, P < 0.001). Age correlated with MCD (r = 0.20, P = 0.01), MOD (r = 0.18, P = 0.03), and CED (r = 0.39, P < 0.001). Males had a lower MOD than females (0.24 vs. 0.26 mm, respectively, P = 0.01); however, there were no differences in MCD or CED between sexes (P > 0.05). There were no significant differences between ethnicities for MCD, MOD, and CED (P > 0.05). Multiple linear regression analysis revealed significant correlations between MCD and IOP (r = -0.65, P < 0.001), CED and age (r = 0.41, P < 0.001), CED and IOP (r = 0.28, P = 0.001), and between CED and central corneal thickness (CCT) (r = -0.36, P < 0.001).
The isolation of the corneal component (MCD) should be used when analyzing deformation characteristics in diseases that only affect the cornea. This study establishes a baseline for a population of healthy eyes. Future publications will identify differences in MCD, MOD, and CED between healthy and diseased populations. |
---|---|
ISSN: | 1552-5783 1552-5783 |
DOI: | 10.1167/iovs.15-17396 |