Determining PM2.5 calibration curves for a low-cost particle monitor: common indoor residential aerosols

Real-time particle monitors are essential for accurately estimating exposure to fine particles indoors. However, many such monitors tend to be prohibitively expensive for some applications, such as a tenant or homeowner curious about the quality of the air in their home. A lower cost version (the Dy...

Full description

Saved in:
Bibliographic Details
Published in:Environmental science--processes & impacts 2015-11, Vol.17 (11), p.1959-1966
Main Authors: Dacunto, Philip J, Klepeis, Neil E, Cheng, Kai-Chung, Acevedo-Bolton, Viviana, Jiang, Ruo-Ting, Repace, James L, Ott, Wayne R, Hildemann, Lynn M
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 1966
container_issue 11
container_start_page 1959
container_title Environmental science--processes & impacts
container_volume 17
creator Dacunto, Philip J
Klepeis, Neil E
Cheng, Kai-Chung
Acevedo-Bolton, Viviana
Jiang, Ruo-Ting
Repace, James L
Ott, Wayne R
Hildemann, Lynn M
description Real-time particle monitors are essential for accurately estimating exposure to fine particles indoors. However, many such monitors tend to be prohibitively expensive for some applications, such as a tenant or homeowner curious about the quality of the air in their home. A lower cost version (the Dylos Air Quality Monitor) has recently been introduced, but it requires appropriate calibration to reflect the mass concentration units required for exposure assessment. We conducted a total of 64 experiments with a suite of instruments including a Dylos DC1100, another real-time laser photometer (TSI SidePak™ Model AM-510 Personal Aerosol Monitor), and a gravimetric sampling apparatus to estimate Dylos calibration factors for emissions from 17 different common indoor sources including cigarettes, incense, fried bacon, chicken, and hamburger. Comparison of minute-by-minute data from the Dylos with the gravimetrically calibrated SidePak yielded relationships that enable the conversion of the raw Dylos particle counts less than 2.5 μm (in #/0.01 ft(3)) to estimated PM2.5 mass concentration (e.g. μg m(-3)). The relationship between the exponentially-decaying Dylos particle counts and PM2.5 mass concentration can be described by a theoretically-derived power law with source-specific empirical parameters. A linear relationship (calibration factor) is applicable to fresh or quickly decaying emissions (i.e., before the aerosol has aged and differential decay rates introduce curvature into the relationship). The empirical parameters for the power-law relationships vary greatly both between and within source types, although linear factors appear to have lower uncertainty. The Dylos Air Quality Monitor is likely most useful for providing instantaneous feedback and context on mass particle levels in home and work situations for field-survey or personal awareness applications.
doi_str_mv 10.1039/c5em00365b
format article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_1730679213</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1730679213</sourcerecordid><originalsourceid>FETCH-LOGICAL-g318t-a9ea27ebf831b58d7d98d697a0ed285867b69f35ee755d8328a0268bd8c87e7f3</originalsourceid><addsrcrecordid>eNo1kDtPwzAYRS0kRKvShR-APLKk-FE_wobKUyqCAebIsb8UIycutgPi3xOJcpdzh6M7XITOKFlRwutLK6AnhEvRHqE5I4JUStdihpY5f5ApWlAt5AmaMbnWas3kHL3fQIHU-8EPO_zyxFYCWxN8m0zxccB2TF-QcRcTNjjE78rGXPDepOJtANzHwZeYrrCN_dSxH1yc1ATZOxiKNwEbSDHHkE_RcWdChuWBC_R2d_u6eai2z_ePm-ttteNUl8rUYJiCttOctkI75WrtZK0MAce00FK1su64AFBCOM2ZNoRJ3TpttQLV8QW6-Nvdp_g5Qi5N77OFEMwAccwNVZxIVTPKJ_X8oI5tD67ZJ9-b9NP8v8N_ATQlZh8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1730679213</pqid></control><display><type>article</type><title>Determining PM2.5 calibration curves for a low-cost particle monitor: common indoor residential aerosols</title><source>Royal Society of Chemistry:Jisc Collections:Royal Society of Chemistry Read and Publish 2022-2024 (reading list)</source><creator>Dacunto, Philip J ; Klepeis, Neil E ; Cheng, Kai-Chung ; Acevedo-Bolton, Viviana ; Jiang, Ruo-Ting ; Repace, James L ; Ott, Wayne R ; Hildemann, Lynn M</creator><creatorcontrib>Dacunto, Philip J ; Klepeis, Neil E ; Cheng, Kai-Chung ; Acevedo-Bolton, Viviana ; Jiang, Ruo-Ting ; Repace, James L ; Ott, Wayne R ; Hildemann, Lynn M</creatorcontrib><description>Real-time particle monitors are essential for accurately estimating exposure to fine particles indoors. However, many such monitors tend to be prohibitively expensive for some applications, such as a tenant or homeowner curious about the quality of the air in their home. A lower cost version (the Dylos Air Quality Monitor) has recently been introduced, but it requires appropriate calibration to reflect the mass concentration units required for exposure assessment. We conducted a total of 64 experiments with a suite of instruments including a Dylos DC1100, another real-time laser photometer (TSI SidePak™ Model AM-510 Personal Aerosol Monitor), and a gravimetric sampling apparatus to estimate Dylos calibration factors for emissions from 17 different common indoor sources including cigarettes, incense, fried bacon, chicken, and hamburger. Comparison of minute-by-minute data from the Dylos with the gravimetrically calibrated SidePak yielded relationships that enable the conversion of the raw Dylos particle counts less than 2.5 μm (in #/0.01 ft(3)) to estimated PM2.5 mass concentration (e.g. μg m(-3)). The relationship between the exponentially-decaying Dylos particle counts and PM2.5 mass concentration can be described by a theoretically-derived power law with source-specific empirical parameters. A linear relationship (calibration factor) is applicable to fresh or quickly decaying emissions (i.e., before the aerosol has aged and differential decay rates introduce curvature into the relationship). The empirical parameters for the power-law relationships vary greatly both between and within source types, although linear factors appear to have lower uncertainty. The Dylos Air Quality Monitor is likely most useful for providing instantaneous feedback and context on mass particle levels in home and work situations for field-survey or personal awareness applications.</description><identifier>EISSN: 2050-7895</identifier><identifier>DOI: 10.1039/c5em00365b</identifier><identifier>PMID: 26487426</identifier><language>eng</language><publisher>England</publisher><subject>Aerosols - analysis ; Air Pollution, Indoor - analysis ; Air Pollution, Indoor - statistics &amp; numerical data ; Calibration ; Environmental Monitoring - instrumentation ; Environmental Monitoring - standards ; Particle Size ; Particulate Matter - analysis ; Particulate Matter - standards</subject><ispartof>Environmental science--processes &amp; impacts, 2015-11, Vol.17 (11), p.1959-1966</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,778,782,27907,27908</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/26487426$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Dacunto, Philip J</creatorcontrib><creatorcontrib>Klepeis, Neil E</creatorcontrib><creatorcontrib>Cheng, Kai-Chung</creatorcontrib><creatorcontrib>Acevedo-Bolton, Viviana</creatorcontrib><creatorcontrib>Jiang, Ruo-Ting</creatorcontrib><creatorcontrib>Repace, James L</creatorcontrib><creatorcontrib>Ott, Wayne R</creatorcontrib><creatorcontrib>Hildemann, Lynn M</creatorcontrib><title>Determining PM2.5 calibration curves for a low-cost particle monitor: common indoor residential aerosols</title><title>Environmental science--processes &amp; impacts</title><addtitle>Environ Sci Process Impacts</addtitle><description>Real-time particle monitors are essential for accurately estimating exposure to fine particles indoors. However, many such monitors tend to be prohibitively expensive for some applications, such as a tenant or homeowner curious about the quality of the air in their home. A lower cost version (the Dylos Air Quality Monitor) has recently been introduced, but it requires appropriate calibration to reflect the mass concentration units required for exposure assessment. We conducted a total of 64 experiments with a suite of instruments including a Dylos DC1100, another real-time laser photometer (TSI SidePak™ Model AM-510 Personal Aerosol Monitor), and a gravimetric sampling apparatus to estimate Dylos calibration factors for emissions from 17 different common indoor sources including cigarettes, incense, fried bacon, chicken, and hamburger. Comparison of minute-by-minute data from the Dylos with the gravimetrically calibrated SidePak yielded relationships that enable the conversion of the raw Dylos particle counts less than 2.5 μm (in #/0.01 ft(3)) to estimated PM2.5 mass concentration (e.g. μg m(-3)). The relationship between the exponentially-decaying Dylos particle counts and PM2.5 mass concentration can be described by a theoretically-derived power law with source-specific empirical parameters. A linear relationship (calibration factor) is applicable to fresh or quickly decaying emissions (i.e., before the aerosol has aged and differential decay rates introduce curvature into the relationship). The empirical parameters for the power-law relationships vary greatly both between and within source types, although linear factors appear to have lower uncertainty. The Dylos Air Quality Monitor is likely most useful for providing instantaneous feedback and context on mass particle levels in home and work situations for field-survey or personal awareness applications.</description><subject>Aerosols - analysis</subject><subject>Air Pollution, Indoor - analysis</subject><subject>Air Pollution, Indoor - statistics &amp; numerical data</subject><subject>Calibration</subject><subject>Environmental Monitoring - instrumentation</subject><subject>Environmental Monitoring - standards</subject><subject>Particle Size</subject><subject>Particulate Matter - analysis</subject><subject>Particulate Matter - standards</subject><issn>2050-7895</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><recordid>eNo1kDtPwzAYRS0kRKvShR-APLKk-FE_wobKUyqCAebIsb8UIycutgPi3xOJcpdzh6M7XITOKFlRwutLK6AnhEvRHqE5I4JUStdihpY5f5ApWlAt5AmaMbnWas3kHL3fQIHU-8EPO_zyxFYCWxN8m0zxccB2TF-QcRcTNjjE78rGXPDepOJtANzHwZeYrrCN_dSxH1yc1ATZOxiKNwEbSDHHkE_RcWdChuWBC_R2d_u6eai2z_ePm-ttteNUl8rUYJiCttOctkI75WrtZK0MAce00FK1su64AFBCOM2ZNoRJ3TpttQLV8QW6-Nvdp_g5Qi5N77OFEMwAccwNVZxIVTPKJ_X8oI5tD67ZJ9-b9NP8v8N_ATQlZh8</recordid><startdate>20151101</startdate><enddate>20151101</enddate><creator>Dacunto, Philip J</creator><creator>Klepeis, Neil E</creator><creator>Cheng, Kai-Chung</creator><creator>Acevedo-Bolton, Viviana</creator><creator>Jiang, Ruo-Ting</creator><creator>Repace, James L</creator><creator>Ott, Wayne R</creator><creator>Hildemann, Lynn M</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>20151101</creationdate><title>Determining PM2.5 calibration curves for a low-cost particle monitor: common indoor residential aerosols</title><author>Dacunto, Philip J ; Klepeis, Neil E ; Cheng, Kai-Chung ; Acevedo-Bolton, Viviana ; Jiang, Ruo-Ting ; Repace, James L ; Ott, Wayne R ; Hildemann, Lynn M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-g318t-a9ea27ebf831b58d7d98d697a0ed285867b69f35ee755d8328a0268bd8c87e7f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Aerosols - analysis</topic><topic>Air Pollution, Indoor - analysis</topic><topic>Air Pollution, Indoor - statistics &amp; numerical data</topic><topic>Calibration</topic><topic>Environmental Monitoring - instrumentation</topic><topic>Environmental Monitoring - standards</topic><topic>Particle Size</topic><topic>Particulate Matter - analysis</topic><topic>Particulate Matter - standards</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Dacunto, Philip J</creatorcontrib><creatorcontrib>Klepeis, Neil E</creatorcontrib><creatorcontrib>Cheng, Kai-Chung</creatorcontrib><creatorcontrib>Acevedo-Bolton, Viviana</creatorcontrib><creatorcontrib>Jiang, Ruo-Ting</creatorcontrib><creatorcontrib>Repace, James L</creatorcontrib><creatorcontrib>Ott, Wayne R</creatorcontrib><creatorcontrib>Hildemann, Lynn M</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>Environmental science--processes &amp; impacts</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Dacunto, Philip J</au><au>Klepeis, Neil E</au><au>Cheng, Kai-Chung</au><au>Acevedo-Bolton, Viviana</au><au>Jiang, Ruo-Ting</au><au>Repace, James L</au><au>Ott, Wayne R</au><au>Hildemann, Lynn M</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Determining PM2.5 calibration curves for a low-cost particle monitor: common indoor residential aerosols</atitle><jtitle>Environmental science--processes &amp; impacts</jtitle><addtitle>Environ Sci Process Impacts</addtitle><date>2015-11-01</date><risdate>2015</risdate><volume>17</volume><issue>11</issue><spage>1959</spage><epage>1966</epage><pages>1959-1966</pages><eissn>2050-7895</eissn><abstract>Real-time particle monitors are essential for accurately estimating exposure to fine particles indoors. However, many such monitors tend to be prohibitively expensive for some applications, such as a tenant or homeowner curious about the quality of the air in their home. A lower cost version (the Dylos Air Quality Monitor) has recently been introduced, but it requires appropriate calibration to reflect the mass concentration units required for exposure assessment. We conducted a total of 64 experiments with a suite of instruments including a Dylos DC1100, another real-time laser photometer (TSI SidePak™ Model AM-510 Personal Aerosol Monitor), and a gravimetric sampling apparatus to estimate Dylos calibration factors for emissions from 17 different common indoor sources including cigarettes, incense, fried bacon, chicken, and hamburger. Comparison of minute-by-minute data from the Dylos with the gravimetrically calibrated SidePak yielded relationships that enable the conversion of the raw Dylos particle counts less than 2.5 μm (in #/0.01 ft(3)) to estimated PM2.5 mass concentration (e.g. μg m(-3)). The relationship between the exponentially-decaying Dylos particle counts and PM2.5 mass concentration can be described by a theoretically-derived power law with source-specific empirical parameters. A linear relationship (calibration factor) is applicable to fresh or quickly decaying emissions (i.e., before the aerosol has aged and differential decay rates introduce curvature into the relationship). The empirical parameters for the power-law relationships vary greatly both between and within source types, although linear factors appear to have lower uncertainty. The Dylos Air Quality Monitor is likely most useful for providing instantaneous feedback and context on mass particle levels in home and work situations for field-survey or personal awareness applications.</abstract><cop>England</cop><pmid>26487426</pmid><doi>10.1039/c5em00365b</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier EISSN: 2050-7895
ispartof Environmental science--processes & impacts, 2015-11, Vol.17 (11), p.1959-1966
issn 2050-7895
language eng
recordid cdi_proquest_miscellaneous_1730679213
source Royal Society of Chemistry:Jisc Collections:Royal Society of Chemistry Read and Publish 2022-2024 (reading list)
subjects Aerosols - analysis
Air Pollution, Indoor - analysis
Air Pollution, Indoor - statistics & numerical data
Calibration
Environmental Monitoring - instrumentation
Environmental Monitoring - standards
Particle Size
Particulate Matter - analysis
Particulate Matter - standards
title Determining PM2.5 calibration curves for a low-cost particle monitor: common indoor residential aerosols
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-16T17%3A28%3A18IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Determining%20PM2.5%20calibration%20curves%20for%20a%20low-cost%20particle%20monitor:%20common%20indoor%20residential%20aerosols&rft.jtitle=Environmental%20science--processes%20&%20impacts&rft.au=Dacunto,%20Philip%20J&rft.date=2015-11-01&rft.volume=17&rft.issue=11&rft.spage=1959&rft.epage=1966&rft.pages=1959-1966&rft.eissn=2050-7895&rft_id=info:doi/10.1039/c5em00365b&rft_dat=%3Cproquest_pubme%3E1730679213%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-g318t-a9ea27ebf831b58d7d98d697a0ed285867b69f35ee755d8328a0268bd8c87e7f3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1730679213&rft_id=info:pmid/26487426&rfr_iscdi=true