Loading…

Effect of millimeter waves on cyclophosphamide induced suppression of the immune system

The effect of millimeter electromagnetic waves (MWs) on cyclophosphamide (CPA) induced toxicity to leukocytes, bone marrow cells, and T‐cell‐mediated immunity was examined. For studying the effect of MWs on CPA induced leukopenia and myelosuppression, BALB/C mice were irradiated for 3 days, 30 min e...

Full description

Saved in:
Bibliographic Details
Published in:Bioelectromagnetics 2002-12, Vol.23 (8), p.614-621
Main Authors: Logani, Mahendra K., Anga, Altaf, Szabo, Imre, Agelan, Alexis, Irizarry, Armando R., Ziskin, Marvin C.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c3908-bf0d74ee0f8af4c8613104710258f3d6180691b91acc462706bf0099dce6b2463
cites cdi_FETCH-LOGICAL-c3908-bf0d74ee0f8af4c8613104710258f3d6180691b91acc462706bf0099dce6b2463
container_end_page 621
container_issue 8
container_start_page 614
container_title Bioelectromagnetics
container_volume 23
creator Logani, Mahendra K.
Anga, Altaf
Szabo, Imre
Agelan, Alexis
Irizarry, Armando R.
Ziskin, Marvin C.
description The effect of millimeter electromagnetic waves (MWs) on cyclophosphamide (CPA) induced toxicity to leukocytes, bone marrow cells, and T‐cell‐mediated immunity was examined. For studying the effect of MWs on CPA induced leukopenia and myelosuppression, BALB/C mice were irradiated for 3 days, 30 min each day, prior to administration of CPA (200 mg/kg). MWs were produced with a Russian made YAV‐1 generator. The device produced 42.2 ± 0.2 GHz modulated wave radiation through a 10 mm × 20 mm rectangular output horn. The animals were irradiated on the nose area. Peak SAR and incident power density were measured as 622 ± 100 W/kg and 31 ± 5 mW/cm2, respectively. For studying the effect of MWs on CPA induced suppression of T‐cell mediated immunity, a delayed type hypersensitivity (DTH) assay in mouse skin was used. The DTH reaction in mouse skin was induced by topical application of dinitrochlorobenzene (DNCB) and quantified by measuring the increase in ear thickness and by histological examination. Treatment of animals with CPA significantly (P 
doi_str_mv 10.1002/bem.10058
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_17497592</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>17497592</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3908-bf0d74ee0f8af4c8613104710258f3d6180691b91acc462706bf0099dce6b2463</originalsourceid><addsrcrecordid>eNp1kE1P20AQhldVUQkfh_4B5FOlHkxm_bEfx5aGgBRoD0CiXlb2elZZ8MbGawP592xIKKeeZqR53leah5CvFE4pQDIu0W2WXHwiI5onNKaCLT6TEVDJY5GxZJ8ceH8PAEJA-oXs0ySVeUb5iMwnxqDuo8ZEzta1ddhjFz0XT-ijZhXpta6bdtn4dlk4W2FkV9WgsYr80LYdem8DFLL9MpycG1YY-bXv0R2RPVPUHo9385Dcnk9uzi7i2e_p5dmPWaxTCSIuDVQ8QwQjCpNpwWhKIeMUklyYtGJUAJO0lLTQOvzBgYUESFlpZGWSsfSQfNv2tl3zOKDvlbNeY10XK2wGryjPJM9lEsDvW1B3jfcdGtV21hXdWlFQG4sqWFRvFgN7sisdSofVB7nTFoDxFni2Na7_36R-Tq7eK-NtwgY7L_8SRfegGE95rubXUzUXf-74r78LNU1fAcm7i3Q</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>17497592</pqid></control><display><type>article</type><title>Effect of millimeter waves on cyclophosphamide induced suppression of the immune system</title><source>Wiley-Blackwell Read &amp; Publish Collection</source><creator>Logani, Mahendra K. ; Anga, Altaf ; Szabo, Imre ; Agelan, Alexis ; Irizarry, Armando R. ; Ziskin, Marvin C.</creator><creatorcontrib>Logani, Mahendra K. ; Anga, Altaf ; Szabo, Imre ; Agelan, Alexis ; Irizarry, Armando R. ; Ziskin, Marvin C.</creatorcontrib><description>The effect of millimeter electromagnetic waves (MWs) on cyclophosphamide (CPA) induced toxicity to leukocytes, bone marrow cells, and T‐cell‐mediated immunity was examined. For studying the effect of MWs on CPA induced leukopenia and myelosuppression, BALB/C mice were irradiated for 3 days, 30 min each day, prior to administration of CPA (200 mg/kg). MWs were produced with a Russian made YAV‐1 generator. The device produced 42.2 ± 0.2 GHz modulated wave radiation through a 10 mm × 20 mm rectangular output horn. The animals were irradiated on the nose area. Peak SAR and incident power density were measured as 622 ± 100 W/kg and 31 ± 5 mW/cm2, respectively. For studying the effect of MWs on CPA induced suppression of T‐cell mediated immunity, a delayed type hypersensitivity (DTH) assay in mouse skin was used. The DTH reaction in mouse skin was induced by topical application of dinitrochlorobenzene (DNCB) and quantified by measuring the increase in ear thickness and by histological examination. Treatment of animals with CPA significantly (P &lt; 0.05) reduced leukocyte and bone marrow cell population, but MW irradiation did not show any significant protection from the immunosuppressive effects of CPA. Furthermore, MW irradiation did not protect the animals from CPA induced suppression of T‐cell mediated immunity. Bioelectromagnetics 23:614–621, 2002. © 2002 Wiley‐Liss, Inc.</description><identifier>ISSN: 0197-8462</identifier><identifier>EISSN: 1521-186X</identifier><identifier>DOI: 10.1002/bem.10058</identifier><identifier>PMID: 12395417</identifier><language>eng</language><publisher>New York: Wiley Subscription Services, Inc., A Wiley Company</publisher><subject>Administration, Topical ; Animals ; Body Weight - drug effects ; Body Weight - radiation effects ; Bone Marrow Cells - drug effects ; Bone Marrow Cells - radiation effects ; Cyclophosphamide - administration &amp; dosage ; delayed type hypersensitivity ; Dinitrochlorobenzene - administration &amp; dosage ; Dinitrochlorobenzene - pharmacology ; Drug Hypersensitivity - immunology ; Ear ; Hypersensitivity, Delayed - chemically induced ; Hypersensitivity, Delayed - immunology ; Immune Tolerance - drug effects ; Immune Tolerance - immunology ; Immune Tolerance - radiation effects ; Immunity, Cellular - drug effects ; Immunity, Cellular - radiation effects ; Immunosuppression - methods ; Injections, Intraperitoneal ; Leukocyte Count ; Leukocytes - drug effects ; Leukocytes - radiation effects ; leukopenia ; Leukopenia - chemically induced ; Male ; Mice ; Mice, Inbred BALB C ; Microwaves ; myelosuppression ; Nose - immunology ; Reference Values ; Skin - drug effects ; Skin - immunology ; Skin - radiation effects ; T-cell mediated immunity ; T-Lymphocytes, Regulatory - drug effects ; T-Lymphocytes, Regulatory - immunology ; T-Lymphocytes, Regulatory - radiation effects ; Whole-Body Irradiation</subject><ispartof>Bioelectromagnetics, 2002-12, Vol.23 (8), p.614-621</ispartof><rights>Copyright © 2002 Wiley‐Liss, Inc.</rights><rights>Copyright 2002 Wiley-Liss, Inc.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3908-bf0d74ee0f8af4c8613104710258f3d6180691b91acc462706bf0099dce6b2463</citedby><cites>FETCH-LOGICAL-c3908-bf0d74ee0f8af4c8613104710258f3d6180691b91acc462706bf0099dce6b2463</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/12395417$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Logani, Mahendra K.</creatorcontrib><creatorcontrib>Anga, Altaf</creatorcontrib><creatorcontrib>Szabo, Imre</creatorcontrib><creatorcontrib>Agelan, Alexis</creatorcontrib><creatorcontrib>Irizarry, Armando R.</creatorcontrib><creatorcontrib>Ziskin, Marvin C.</creatorcontrib><title>Effect of millimeter waves on cyclophosphamide induced suppression of the immune system</title><title>Bioelectromagnetics</title><addtitle>Bioelectromagnetics</addtitle><description>The effect of millimeter electromagnetic waves (MWs) on cyclophosphamide (CPA) induced toxicity to leukocytes, bone marrow cells, and T‐cell‐mediated immunity was examined. For studying the effect of MWs on CPA induced leukopenia and myelosuppression, BALB/C mice were irradiated for 3 days, 30 min each day, prior to administration of CPA (200 mg/kg). MWs were produced with a Russian made YAV‐1 generator. The device produced 42.2 ± 0.2 GHz modulated wave radiation through a 10 mm × 20 mm rectangular output horn. The animals were irradiated on the nose area. Peak SAR and incident power density were measured as 622 ± 100 W/kg and 31 ± 5 mW/cm2, respectively. For studying the effect of MWs on CPA induced suppression of T‐cell mediated immunity, a delayed type hypersensitivity (DTH) assay in mouse skin was used. The DTH reaction in mouse skin was induced by topical application of dinitrochlorobenzene (DNCB) and quantified by measuring the increase in ear thickness and by histological examination. Treatment of animals with CPA significantly (P &lt; 0.05) reduced leukocyte and bone marrow cell population, but MW irradiation did not show any significant protection from the immunosuppressive effects of CPA. Furthermore, MW irradiation did not protect the animals from CPA induced suppression of T‐cell mediated immunity. Bioelectromagnetics 23:614–621, 2002. © 2002 Wiley‐Liss, Inc.</description><subject>Administration, Topical</subject><subject>Animals</subject><subject>Body Weight - drug effects</subject><subject>Body Weight - radiation effects</subject><subject>Bone Marrow Cells - drug effects</subject><subject>Bone Marrow Cells - radiation effects</subject><subject>Cyclophosphamide - administration &amp; dosage</subject><subject>delayed type hypersensitivity</subject><subject>Dinitrochlorobenzene - administration &amp; dosage</subject><subject>Dinitrochlorobenzene - pharmacology</subject><subject>Drug Hypersensitivity - immunology</subject><subject>Ear</subject><subject>Hypersensitivity, Delayed - chemically induced</subject><subject>Hypersensitivity, Delayed - immunology</subject><subject>Immune Tolerance - drug effects</subject><subject>Immune Tolerance - immunology</subject><subject>Immune Tolerance - radiation effects</subject><subject>Immunity, Cellular - drug effects</subject><subject>Immunity, Cellular - radiation effects</subject><subject>Immunosuppression - methods</subject><subject>Injections, Intraperitoneal</subject><subject>Leukocyte Count</subject><subject>Leukocytes - drug effects</subject><subject>Leukocytes - radiation effects</subject><subject>leukopenia</subject><subject>Leukopenia - chemically induced</subject><subject>Male</subject><subject>Mice</subject><subject>Mice, Inbred BALB C</subject><subject>Microwaves</subject><subject>myelosuppression</subject><subject>Nose - immunology</subject><subject>Reference Values</subject><subject>Skin - drug effects</subject><subject>Skin - immunology</subject><subject>Skin - radiation effects</subject><subject>T-cell mediated immunity</subject><subject>T-Lymphocytes, Regulatory - drug effects</subject><subject>T-Lymphocytes, Regulatory - immunology</subject><subject>T-Lymphocytes, Regulatory - radiation effects</subject><subject>Whole-Body Irradiation</subject><issn>0197-8462</issn><issn>1521-186X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2002</creationdate><recordtype>article</recordtype><recordid>eNp1kE1P20AQhldVUQkfh_4B5FOlHkxm_bEfx5aGgBRoD0CiXlb2elZZ8MbGawP592xIKKeeZqR53leah5CvFE4pQDIu0W2WXHwiI5onNKaCLT6TEVDJY5GxZJ8ceH8PAEJA-oXs0ySVeUb5iMwnxqDuo8ZEzta1ddhjFz0XT-ijZhXpta6bdtn4dlk4W2FkV9WgsYr80LYdem8DFLL9MpycG1YY-bXv0R2RPVPUHo9385Dcnk9uzi7i2e_p5dmPWaxTCSIuDVQ8QwQjCpNpwWhKIeMUklyYtGJUAJO0lLTQOvzBgYUESFlpZGWSsfSQfNv2tl3zOKDvlbNeY10XK2wGryjPJM9lEsDvW1B3jfcdGtV21hXdWlFQG4sqWFRvFgN7sisdSofVB7nTFoDxFni2Na7_36R-Tq7eK-NtwgY7L_8SRfegGE95rubXUzUXf-74r78LNU1fAcm7i3Q</recordid><startdate>200212</startdate><enddate>200212</enddate><creator>Logani, Mahendra K.</creator><creator>Anga, Altaf</creator><creator>Szabo, Imre</creator><creator>Agelan, Alexis</creator><creator>Irizarry, Armando R.</creator><creator>Ziskin, Marvin C.</creator><general>Wiley Subscription Services, Inc., A Wiley Company</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7U7</scope><scope>C1K</scope></search><sort><creationdate>200212</creationdate><title>Effect of millimeter waves on cyclophosphamide induced suppression of the immune system</title><author>Logani, Mahendra K. ; Anga, Altaf ; Szabo, Imre ; Agelan, Alexis ; Irizarry, Armando R. ; Ziskin, Marvin C.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3908-bf0d74ee0f8af4c8613104710258f3d6180691b91acc462706bf0099dce6b2463</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2002</creationdate><topic>Administration, Topical</topic><topic>Animals</topic><topic>Body Weight - drug effects</topic><topic>Body Weight - radiation effects</topic><topic>Bone Marrow Cells - drug effects</topic><topic>Bone Marrow Cells - radiation effects</topic><topic>Cyclophosphamide - administration &amp; dosage</topic><topic>delayed type hypersensitivity</topic><topic>Dinitrochlorobenzene - administration &amp; dosage</topic><topic>Dinitrochlorobenzene - pharmacology</topic><topic>Drug Hypersensitivity - immunology</topic><topic>Ear</topic><topic>Hypersensitivity, Delayed - chemically induced</topic><topic>Hypersensitivity, Delayed - immunology</topic><topic>Immune Tolerance - drug effects</topic><topic>Immune Tolerance - immunology</topic><topic>Immune Tolerance - radiation effects</topic><topic>Immunity, Cellular - drug effects</topic><topic>Immunity, Cellular - radiation effects</topic><topic>Immunosuppression - methods</topic><topic>Injections, Intraperitoneal</topic><topic>Leukocyte Count</topic><topic>Leukocytes - drug effects</topic><topic>Leukocytes - radiation effects</topic><topic>leukopenia</topic><topic>Leukopenia - chemically induced</topic><topic>Male</topic><topic>Mice</topic><topic>Mice, Inbred BALB C</topic><topic>Microwaves</topic><topic>myelosuppression</topic><topic>Nose - immunology</topic><topic>Reference Values</topic><topic>Skin - drug effects</topic><topic>Skin - immunology</topic><topic>Skin - radiation effects</topic><topic>T-cell mediated immunity</topic><topic>T-Lymphocytes, Regulatory - drug effects</topic><topic>T-Lymphocytes, Regulatory - immunology</topic><topic>T-Lymphocytes, Regulatory - radiation effects</topic><topic>Whole-Body Irradiation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Logani, Mahendra K.</creatorcontrib><creatorcontrib>Anga, Altaf</creatorcontrib><creatorcontrib>Szabo, Imre</creatorcontrib><creatorcontrib>Agelan, Alexis</creatorcontrib><creatorcontrib>Irizarry, Armando R.</creatorcontrib><creatorcontrib>Ziskin, Marvin C.</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Toxicology Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><jtitle>Bioelectromagnetics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Logani, Mahendra K.</au><au>Anga, Altaf</au><au>Szabo, Imre</au><au>Agelan, Alexis</au><au>Irizarry, Armando R.</au><au>Ziskin, Marvin C.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Effect of millimeter waves on cyclophosphamide induced suppression of the immune system</atitle><jtitle>Bioelectromagnetics</jtitle><addtitle>Bioelectromagnetics</addtitle><date>2002-12</date><risdate>2002</risdate><volume>23</volume><issue>8</issue><spage>614</spage><epage>621</epage><pages>614-621</pages><issn>0197-8462</issn><eissn>1521-186X</eissn><abstract>The effect of millimeter electromagnetic waves (MWs) on cyclophosphamide (CPA) induced toxicity to leukocytes, bone marrow cells, and T‐cell‐mediated immunity was examined. For studying the effect of MWs on CPA induced leukopenia and myelosuppression, BALB/C mice were irradiated for 3 days, 30 min each day, prior to administration of CPA (200 mg/kg). MWs were produced with a Russian made YAV‐1 generator. The device produced 42.2 ± 0.2 GHz modulated wave radiation through a 10 mm × 20 mm rectangular output horn. The animals were irradiated on the nose area. Peak SAR and incident power density were measured as 622 ± 100 W/kg and 31 ± 5 mW/cm2, respectively. For studying the effect of MWs on CPA induced suppression of T‐cell mediated immunity, a delayed type hypersensitivity (DTH) assay in mouse skin was used. The DTH reaction in mouse skin was induced by topical application of dinitrochlorobenzene (DNCB) and quantified by measuring the increase in ear thickness and by histological examination. Treatment of animals with CPA significantly (P &lt; 0.05) reduced leukocyte and bone marrow cell population, but MW irradiation did not show any significant protection from the immunosuppressive effects of CPA. Furthermore, MW irradiation did not protect the animals from CPA induced suppression of T‐cell mediated immunity. Bioelectromagnetics 23:614–621, 2002. © 2002 Wiley‐Liss, Inc.</abstract><cop>New York</cop><pub>Wiley Subscription Services, Inc., A Wiley Company</pub><pmid>12395417</pmid><doi>10.1002/bem.10058</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0197-8462
ispartof Bioelectromagnetics, 2002-12, Vol.23 (8), p.614-621
issn 0197-8462
1521-186X
language eng
recordid cdi_proquest_miscellaneous_17497592
source Wiley-Blackwell Read & Publish Collection
subjects Administration, Topical
Animals
Body Weight - drug effects
Body Weight - radiation effects
Bone Marrow Cells - drug effects
Bone Marrow Cells - radiation effects
Cyclophosphamide - administration & dosage
delayed type hypersensitivity
Dinitrochlorobenzene - administration & dosage
Dinitrochlorobenzene - pharmacology
Drug Hypersensitivity - immunology
Ear
Hypersensitivity, Delayed - chemically induced
Hypersensitivity, Delayed - immunology
Immune Tolerance - drug effects
Immune Tolerance - immunology
Immune Tolerance - radiation effects
Immunity, Cellular - drug effects
Immunity, Cellular - radiation effects
Immunosuppression - methods
Injections, Intraperitoneal
Leukocyte Count
Leukocytes - drug effects
Leukocytes - radiation effects
leukopenia
Leukopenia - chemically induced
Male
Mice
Mice, Inbred BALB C
Microwaves
myelosuppression
Nose - immunology
Reference Values
Skin - drug effects
Skin - immunology
Skin - radiation effects
T-cell mediated immunity
T-Lymphocytes, Regulatory - drug effects
T-Lymphocytes, Regulatory - immunology
T-Lymphocytes, Regulatory - radiation effects
Whole-Body Irradiation
title Effect of millimeter waves on cyclophosphamide induced suppression of the immune system
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-24T05%3A01%3A42IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Effect%20of%20millimeter%20waves%20on%20cyclophosphamide%20induced%20suppression%20of%20the%20immune%20system&rft.jtitle=Bioelectromagnetics&rft.au=Logani,%20Mahendra%20K.&rft.date=2002-12&rft.volume=23&rft.issue=8&rft.spage=614&rft.epage=621&rft.pages=614-621&rft.issn=0197-8462&rft.eissn=1521-186X&rft_id=info:doi/10.1002/bem.10058&rft_dat=%3Cproquest_cross%3E17497592%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c3908-bf0d74ee0f8af4c8613104710258f3d6180691b91acc462706bf0099dce6b2463%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=17497592&rft_id=info:pmid/12395417&rfr_iscdi=true