Fracture toughness measurement in fused quartz using triangular chevron-notched micro-cantilevers
We extend to flat surfaces the fracture toughness method presented in Acta Materialia vol. 86 (2015) p. 385 and measure in this manner the fracture toughness of fused quartz. Tests give 0.67±0.01MPam1/2, which agrees with earlier microscopic and macroscopic test data for the fast fracture toughness...
Saved in:
Published in: | Scripta materialia 2016-02, Vol.112, p.132-135 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | We extend to flat surfaces the fracture toughness method presented in Acta Materialia vol. 86 (2015) p. 385 and measure in this manner the fracture toughness of fused quartz. Tests give 0.67±0.01MPam1/2, which agrees with earlier microscopic and macroscopic test data for the fast fracture toughness of this material. Data show no signs of sub-critical crack growth; this observation is at variance with what one would expect from literature data on the phenomenon.
[Display omitted] |
---|---|
ISSN: | 1359-6462 1872-8456 |
DOI: | 10.1016/j.scriptamat.2015.09.032 |