Loading…
Comparing different reactor configurations for Partial Nitritation/Anammox at low temperatures
Partial Nitritation/Anammox (PN/A) is a well-established technology for side-stream nitrogen removal from highly concentrated, warm wastewaters. The focus has now shifted to weakly concentrated municipal wastewaters with much lower concentrations and temperatures. The major challenge is the temperat...
Saved in:
Published in: | Water research (Oxford) 2015-09, Vol.81, p.92-100 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Partial Nitritation/Anammox (PN/A) is a well-established technology for side-stream nitrogen removal from highly concentrated, warm wastewaters. The focus has now shifted to weakly concentrated municipal wastewaters with much lower concentrations and temperatures. The major challenge is the temperature, which ranges from moderate 20 °C in summer to cold 10 °C in winter. For this study, the most frequently used configurations for side-stream applications were exposed to a slow temperature reduction from 20 °C to 10 °C to simulate a realistic temperature gradient. To evaluate the behavior of the different biomasses based on their properties, four lab reactors were operated in two different configurations. Synthetic wastewater was used to avoid side effects of heterotrophic growth. Differences in the response of the different reactor systems to this temperature gradient clearly indicated, that the geometry of the biomass has a major impact on the overall PN/A performance at low temperatures: While anammox activity in suspended biomass suffered already at 15 °C, it persevered in granular biomass as well as in biofilms on carriers for temperatures down to |
---|---|
ISSN: | 0043-1354 1879-2448 |
DOI: | 10.1016/j.watres.2015.05.022 |