Total energy expenditure assessed by salivary doubly labelled water analysis and its relevance for short-term energy balance in humans
Rationale The doubly labelled water (DLW) method is a stable isotopic technique for measuring total energy expenditure (TEE). Saliva is the easiest sampling fluid for assessing isotopic enrichments, but blood is considered superior because of its rapid exchange with body water. Therefore, we compare...
Saved in:
Published in: | Rapid communications in mass spectrometry 2016-01, Vol.30 (1), p.143-150 |
---|---|
Main Authors: | , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Rationale
The doubly labelled water (DLW) method is a stable isotopic technique for measuring total energy expenditure (TEE). Saliva is the easiest sampling fluid for assessing isotopic enrichments, but blood is considered superior because of its rapid exchange with body water. Therefore, we compared a large range of isotopic enrichments in saliva and blood, and related TEE in subjects with their ad libitum total energy intake (TEI). The relevance of these parameters to body weight and fat change over an 8‐day interval was also assessed.
Methods
Thirty subjects underwent DLW analysis over either 8 or 14 days, during which time initial and final blood and saliva enrichments were compared. TEI was assessed by dieticians over the 8‐day period only. Isotope ratio mass spectrometry was used for the measurement of δ2H and δ18O values.
Results
No discrepancies were observed between sampling fluids over a wide range of enrichments. During the 8‐day period, average TEI exceeded TEE by ~5% or less. Using saliva as sampling fluid, TEI and TEI‐TEE, but not TEE, were positively correlated to body weight change. TEI‐TEE and physical activity EE (AEE), but not TEI, correlated, respectively, positively and negatively to changes in fat mass.
Conclusions
The DLW method in humans can be reliably applied using saliva as sampling fluid. TEI‐TEE as well as AEE contributes significantly to changes in fat mass over an 8‐day period. Copyright © 2015 John Wiley & Sons, Ltd. |
---|---|