Loading…

Comparison of MB/BacT ALERT 3D System with Radiometric BACTEC System and Loewenstein-Jensen Medium for Recovery and Identification of Mycobacteria from Clinical Specimens: a Multicenter Study

The MB/BacT ALERT 3D System (MB/BacT) (Organon Teknika, Boxtel, The Netherlands) is a fully automated, nonradiometric system with a revised antibiotic supplement kit designed for the recovery of mycobacteria from clinical specimens. In a multicenter study, the recovery rate of acid-fast bacilli (AFB...

Full description

Saved in:
Bibliographic Details
Published in:Journal of clinical microbiology 2001-02, Vol.39 (2), p.651-657
Main Authors: Piersimoni, C, Scarparo, C, Callegaro, A, Tosi, C P, Nista, D, Bornigia, S, Scagnelli, M, Rigon, A, Ruggiero, G, Goglio, A
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The MB/BacT ALERT 3D System (MB/BacT) (Organon Teknika, Boxtel, The Netherlands) is a fully automated, nonradiometric system with a revised antibiotic supplement kit designed for the recovery of mycobacteria from clinical specimens. In a multicenter study, the recovery rate of acid-fast bacilli (AFB) and the mean time to their detection from clinical specimens was determined by using the MB/BacT system. Data were compared to those assessed by the radiometric BACTEC 460 system (B460) and by culture on Loewenstein-Jensen (L-J) solid medium. A total of 2,859 respiratory and extrapulmonary specimens were processed by the N-acetyl-L-cysteine (NALC)-NaOH method using two different concentrations of sodium hydroxide; 1.5% was adopted in study design A (1,766 specimens), and 1.0% was used in study design B (1,093 specimens). The contamination rates for MB/BacT were 4.6% (study design A) and 7.1% (study design B). One hundred seventy-nine mycobacterial isolates were detected by study design A, with 148 Mycobacterium tuberculosis complex (MTB) isolates and 31 nontuberculous mycobacteria (NTM) isolates. Overall recovery rates were 78.8% for MB/BacT (P = 0.0049), 64.2% for L-J (P < 0.0001), and 87.1% for B460, whereas they were 84.5, 70.9, and 91.2%, respectively, for MTB alone. A total of 125 mycobacteria were detected by study design B, with 46 MTB and 79 NTM. Overall recovery rates by the individual systems were 57.6% (P = 0.0002), 56.8% (P = 0.0001), and 80% for MB/BacT, L-J, and B460, respectively, whereas the rates were 91.3, 78.3, and 97.8% for MTB alone. By study design A, the mean times to detection of smear-positive MTB, smear-negative MTB, and NTM were 11.5, 19.9, and 19.6 days, respectively, with the MB/BacT; 8.3, 16.8, and 16.6 days, respectively, with the B460; and 20.6, 32.1, and 27.8 days, respectively, with L-J medium. By study design B, the mean times were 15.1, 26.7, and 26 days with the MB/BacT; 11.7, 21.3, and 24.8 days with the B460; and 20.4, 28.7, and 28.4 days with L-J medium. Identification was attempted by probing (Accuprobe) MB/BacT-positive bottles within the first working day following instrument positive flag. Results were compared to those obtained in the B460 positive vials by the p-nitro- alpha -acetylamino- beta -hydroxypropiophenone (NAP) test (study design A) or by the Accuprobe assay (study design B). About 90% of MTB and 100% of NTM could be identified, showing turnaround times closely related to those obtained by combining B460
ISSN:0095-1137