Loading…

Self-assembled monolayers of crown ethers for solid phase extraction in flow-injection analysis

Modification of a gold electrode with 2-[(6-mercaptohexyl)oxy]methyl-15-crown-5 yielded a self-assembled monolayer (SAM), CESAM, that preconcentrated Pb(II) from aqueous solution. With a 20 h modification, measurements by the copper underpotential deposition method showed that the fraction of the su...

Full description

Saved in:
Bibliographic Details
Published in:Analytica chimica acta 2003-08, Vol.489 (1), p.13-19
Main Authors: Kijak, Anna M, Cox, James A
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c368t-5ab2c1ed3d89e6ef63ee834c004f7f656d1863b9c3ca06ec5ed59ac62d5fe1fa3
cites cdi_FETCH-LOGICAL-c368t-5ab2c1ed3d89e6ef63ee834c004f7f656d1863b9c3ca06ec5ed59ac62d5fe1fa3
container_end_page 19
container_issue 1
container_start_page 13
container_title Analytica chimica acta
container_volume 489
creator Kijak, Anna M
Cox, James A
description Modification of a gold electrode with 2-[(6-mercaptohexyl)oxy]methyl-15-crown-5 yielded a self-assembled monolayer (SAM), CESAM, that preconcentrated Pb(II) from aqueous solution. With a 20 h modification, measurements by the copper underpotential deposition method showed that the fraction of the surface covered, Θ, was 0.99. Proof-of-concept was obtained for an analytical strategy in which the Pb(II)-CESAM was released into a flow stream by electrochemical oxidation of the gold thiolate and detected amperometrically. A detection limit of 6 pmol Pb(II) was estimated from the signal-to-noise ratio. Electrochemical release into a flow injection analysis system with detection by argon inductively coupled plasma spectroscopy provided detection of 0.2 nmol Pb(II) in a 200 μL injection. Analytical utility requires rapid, reproducible renewal of the CESAM. With 30–90 s modifications, Θ=0.97±0.01 and was independent of modification time over that range.
doi_str_mv 10.1016/S0003-2670(03)00713-X
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_17819548</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S000326700300713X</els_id><sourcerecordid>17819548</sourcerecordid><originalsourceid>FETCH-LOGICAL-c368t-5ab2c1ed3d89e6ef63ee834c004f7f656d1863b9c3ca06ec5ed59ac62d5fe1fa3</originalsourceid><addsrcrecordid>eNqFkE1LAzEQhoMoWD9-gpCLoofVZLPJbk8i4hcIHqrQW0iTCUbSpGbWj_57t1b06GmY4ZkZ3oeQA85OOePqbMIYE1WtWnbMxAljLRfVdIOMeNeKqhF1s0lGv8g22UF8Gdqas2ZE9ASirwwizGcRHJ3nlKNZQkGaPbUlfyQK_fOq97lQzDE4ung2CBQ--2JsH3KiIVEf80cV0gusJyaZuMSAe2TLm4iw_1N3ydP11ePlbXX_cHN3eXFfWaG6vpJmVlsOTrhuDAq8EgCdaCxjjW-9ksrxTonZ2AprmAIrwcmxsap20gP3RuySo_XdRcmvb4C9nge0EKNJkN9Q87bjY9l0AyjX4JANsYDXixLmpiw1Z3qlU3_r1CtXeqjfOvV02Dv8eWDQmuiLSTbg37JkTLZdPXDnaw6GtO8BikYbIFlwoQxutMvhn09fozWMGw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>17819548</pqid></control><display><type>article</type><title>Self-assembled monolayers of crown ethers for solid phase extraction in flow-injection analysis</title><source>Elsevier</source><creator>Kijak, Anna M ; Cox, James A</creator><creatorcontrib>Kijak, Anna M ; Cox, James A</creatorcontrib><description>Modification of a gold electrode with 2-[(6-mercaptohexyl)oxy]methyl-15-crown-5 yielded a self-assembled monolayer (SAM), CESAM, that preconcentrated Pb(II) from aqueous solution. With a 20 h modification, measurements by the copper underpotential deposition method showed that the fraction of the surface covered, Θ, was 0.99. Proof-of-concept was obtained for an analytical strategy in which the Pb(II)-CESAM was released into a flow stream by electrochemical oxidation of the gold thiolate and detected amperometrically. A detection limit of 6 pmol Pb(II) was estimated from the signal-to-noise ratio. Electrochemical release into a flow injection analysis system with detection by argon inductively coupled plasma spectroscopy provided detection of 0.2 nmol Pb(II) in a 200 μL injection. Analytical utility requires rapid, reproducible renewal of the CESAM. With 30–90 s modifications, Θ=0.97±0.01 and was independent of modification time over that range.</description><identifier>ISSN: 0003-2670</identifier><identifier>EISSN: 1873-4324</identifier><identifier>DOI: 10.1016/S0003-2670(03)00713-X</identifier><identifier>CODEN: ACACAM</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Analytical chemistry ; Chemistry ; Electrochemical methods ; Exact sciences and technology ; Plasma emission ; Preconcentration ; Self-assembled monolayer ; Spectrometric and optical methods ; Voltammetry</subject><ispartof>Analytica chimica acta, 2003-08, Vol.489 (1), p.13-19</ispartof><rights>2003 Elsevier B.V.</rights><rights>2003 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c368t-5ab2c1ed3d89e6ef63ee834c004f7f656d1863b9c3ca06ec5ed59ac62d5fe1fa3</citedby><cites>FETCH-LOGICAL-c368t-5ab2c1ed3d89e6ef63ee834c004f7f656d1863b9c3ca06ec5ed59ac62d5fe1fa3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,777,781,27905,27906</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=15005782$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Kijak, Anna M</creatorcontrib><creatorcontrib>Cox, James A</creatorcontrib><title>Self-assembled monolayers of crown ethers for solid phase extraction in flow-injection analysis</title><title>Analytica chimica acta</title><description>Modification of a gold electrode with 2-[(6-mercaptohexyl)oxy]methyl-15-crown-5 yielded a self-assembled monolayer (SAM), CESAM, that preconcentrated Pb(II) from aqueous solution. With a 20 h modification, measurements by the copper underpotential deposition method showed that the fraction of the surface covered, Θ, was 0.99. Proof-of-concept was obtained for an analytical strategy in which the Pb(II)-CESAM was released into a flow stream by electrochemical oxidation of the gold thiolate and detected amperometrically. A detection limit of 6 pmol Pb(II) was estimated from the signal-to-noise ratio. Electrochemical release into a flow injection analysis system with detection by argon inductively coupled plasma spectroscopy provided detection of 0.2 nmol Pb(II) in a 200 μL injection. Analytical utility requires rapid, reproducible renewal of the CESAM. With 30–90 s modifications, Θ=0.97±0.01 and was independent of modification time over that range.</description><subject>Analytical chemistry</subject><subject>Chemistry</subject><subject>Electrochemical methods</subject><subject>Exact sciences and technology</subject><subject>Plasma emission</subject><subject>Preconcentration</subject><subject>Self-assembled monolayer</subject><subject>Spectrometric and optical methods</subject><subject>Voltammetry</subject><issn>0003-2670</issn><issn>1873-4324</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2003</creationdate><recordtype>article</recordtype><recordid>eNqFkE1LAzEQhoMoWD9-gpCLoofVZLPJbk8i4hcIHqrQW0iTCUbSpGbWj_57t1b06GmY4ZkZ3oeQA85OOePqbMIYE1WtWnbMxAljLRfVdIOMeNeKqhF1s0lGv8g22UF8Gdqas2ZE9ASirwwizGcRHJ3nlKNZQkGaPbUlfyQK_fOq97lQzDE4ung2CBQ--2JsH3KiIVEf80cV0gusJyaZuMSAe2TLm4iw_1N3ydP11ePlbXX_cHN3eXFfWaG6vpJmVlsOTrhuDAq8EgCdaCxjjW-9ksrxTonZ2AprmAIrwcmxsap20gP3RuySo_XdRcmvb4C9nge0EKNJkN9Q87bjY9l0AyjX4JANsYDXixLmpiw1Z3qlU3_r1CtXeqjfOvV02Dv8eWDQmuiLSTbg37JkTLZdPXDnaw6GtO8BikYbIFlwoQxutMvhn09fozWMGw</recordid><startdate>20030811</startdate><enddate>20030811</enddate><creator>Kijak, Anna M</creator><creator>Cox, James A</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>C1K</scope><scope>F1W</scope><scope>H97</scope><scope>L.G</scope></search><sort><creationdate>20030811</creationdate><title>Self-assembled monolayers of crown ethers for solid phase extraction in flow-injection analysis</title><author>Kijak, Anna M ; Cox, James A</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c368t-5ab2c1ed3d89e6ef63ee834c004f7f656d1863b9c3ca06ec5ed59ac62d5fe1fa3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2003</creationdate><topic>Analytical chemistry</topic><topic>Chemistry</topic><topic>Electrochemical methods</topic><topic>Exact sciences and technology</topic><topic>Plasma emission</topic><topic>Preconcentration</topic><topic>Self-assembled monolayer</topic><topic>Spectrometric and optical methods</topic><topic>Voltammetry</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kijak, Anna M</creatorcontrib><creatorcontrib>Cox, James A</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ASFA: Aquatic Sciences and Fisheries Abstracts</collection><collection>Aquatic Science &amp; Fisheries Abstracts (ASFA) 3: Aquatic Pollution &amp; Environmental Quality</collection><collection>Aquatic Science &amp; Fisheries Abstracts (ASFA) Professional</collection><jtitle>Analytica chimica acta</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kijak, Anna M</au><au>Cox, James A</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Self-assembled monolayers of crown ethers for solid phase extraction in flow-injection analysis</atitle><jtitle>Analytica chimica acta</jtitle><date>2003-08-11</date><risdate>2003</risdate><volume>489</volume><issue>1</issue><spage>13</spage><epage>19</epage><pages>13-19</pages><issn>0003-2670</issn><eissn>1873-4324</eissn><coden>ACACAM</coden><abstract>Modification of a gold electrode with 2-[(6-mercaptohexyl)oxy]methyl-15-crown-5 yielded a self-assembled monolayer (SAM), CESAM, that preconcentrated Pb(II) from aqueous solution. With a 20 h modification, measurements by the copper underpotential deposition method showed that the fraction of the surface covered, Θ, was 0.99. Proof-of-concept was obtained for an analytical strategy in which the Pb(II)-CESAM was released into a flow stream by electrochemical oxidation of the gold thiolate and detected amperometrically. A detection limit of 6 pmol Pb(II) was estimated from the signal-to-noise ratio. Electrochemical release into a flow injection analysis system with detection by argon inductively coupled plasma spectroscopy provided detection of 0.2 nmol Pb(II) in a 200 μL injection. Analytical utility requires rapid, reproducible renewal of the CESAM. With 30–90 s modifications, Θ=0.97±0.01 and was independent of modification time over that range.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><doi>10.1016/S0003-2670(03)00713-X</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0003-2670
ispartof Analytica chimica acta, 2003-08, Vol.489 (1), p.13-19
issn 0003-2670
1873-4324
language eng
recordid cdi_proquest_miscellaneous_17819548
source Elsevier
subjects Analytical chemistry
Chemistry
Electrochemical methods
Exact sciences and technology
Plasma emission
Preconcentration
Self-assembled monolayer
Spectrometric and optical methods
Voltammetry
title Self-assembled monolayers of crown ethers for solid phase extraction in flow-injection analysis
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-19T12%3A48%3A56IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Self-assembled%20monolayers%20of%20crown%20ethers%20for%20solid%20phase%20extraction%20in%20flow-injection%20analysis&rft.jtitle=Analytica%20chimica%20acta&rft.au=Kijak,%20Anna%20M&rft.date=2003-08-11&rft.volume=489&rft.issue=1&rft.spage=13&rft.epage=19&rft.pages=13-19&rft.issn=0003-2670&rft.eissn=1873-4324&rft.coden=ACACAM&rft_id=info:doi/10.1016/S0003-2670(03)00713-X&rft_dat=%3Cproquest_cross%3E17819548%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c368t-5ab2c1ed3d89e6ef63ee834c004f7f656d1863b9c3ca06ec5ed59ac62d5fe1fa3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=17819548&rft_id=info:pmid/&rfr_iscdi=true