Performance of Non-Cemented, Hemispherical, Rim-Fit, Hydroxyapatite Coated Acetabular Component
Abstract The purpose of this study was to assess the durability of a non-cemented, hemispherical rim-fit, hydroxyapatite coated cup with a highly cross-linked polyethylene in 223 total hip arthroplasties. At 6-years follow-up (range, 5–9), there were no cup revisions for osteolysis or loosening. Rad...
Saved in:
Published in: | The Journal of arthroplasty 2015-12, Vol.30 (12), p.2233-2236 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Abstract The purpose of this study was to assess the durability of a non-cemented, hemispherical rim-fit, hydroxyapatite coated cup with a highly cross-linked polyethylene in 223 total hip arthroplasties. At 6-years follow-up (range, 5–9), there were no cup revisions for osteolysis or loosening. Radiologic evidence of osseointegration was based on presence of Stress Induced Reactive Cancellous Bone and radial trabeculae, seen in 47% and 93% of cups, respectively; both were most prevalent in Zone 1. There was no interference demarcation in any zones. Two cups were revised (0.9%): one for dislocation and another for infection. The Kaplan–Meier survivorship for cup revision for any failure (infection, dislocation) was 99% and for mechanical failure (osteolysis, loosening) was 100%. This design has excellent safety, efficacy and durability. |
---|---|
ISSN: | 0883-5403 1532-8406 |
DOI: | 10.1016/j.arth.2015.06.039 |