Loading…

Impact of Advance Control on Microturbine Generation System Performance

Advance control employed in microturbine generation system (MTGS) is expected to improve its performance in responding to grid faults. This paper compares the effect of advance control of MTGS power conversion topology on the performance in riding through the grid faults. The analysis and investigat...

Full description

Saved in:
Bibliographic Details
Published in:IOP conference series. Earth and environmental science 2013-01, Vol.16 (1), p.1-4
Main Authors: Hussin, Ahmad Kamil Mat, Wanik, Mohd Zamri Che
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-LOGICAL-c342t-c3d25c72d76a723aa1b5be2915975f840a4a18119a295fbacbd55c8d5003f47a3
container_end_page 4
container_issue 1
container_start_page 1
container_title IOP conference series. Earth and environmental science
container_volume 16
creator Hussin, Ahmad Kamil Mat
Wanik, Mohd Zamri Che
description Advance control employed in microturbine generation system (MTGS) is expected to improve its performance in responding to grid faults. This paper compares the effect of advance control of MTGS power conversion topology on the performance in riding through the grid faults. The analysis and investigation study through simulation shows there is no significant different on MTGS output performance even advance control is employed for its rectifier.
doi_str_mv 10.1088/1755-1315/16/1/012018
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1786177040</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1566836538</sourcerecordid><originalsourceid>FETCH-LOGICAL-c342t-c3d25c72d76a723aa1b5be2915975f840a4a18119a295fbacbd55c8d5003f47a3</originalsourceid><addsrcrecordid>eNqFUcFKxDAQDaLguvoJQsGLl7WZpJOkx2XRdWFFQT2HNE2hS9usSSvs39uyIuLFy8zwePOYeY-Qa6B3QJVKQSIugAOmIFJIKTAK6oTMfvDTX_M5uYhxR6mQGc9nZL1p98b2ia-SZflpOuuSle_64JvEd8lTbYPvh1DUnUvWrnPB9PWIvx5i79rkxYXKh3bauiRnlWmiu_ruc_L-cP-2elxsn9eb1XK7sDxj_VhLhlayUgojGTcGCiwcywFziZXKqMkMKIDcsByrwtiiRLSqREp5lUnD5-T2qLsP_mNwsddtHa1rGtM5P0QNUgmQkmb0fyoKobhArkbqzR_qzg-hGx_RDMfDc57RSRCPrNGUGIOr9D7UrQkHDVRPSejJZT25rEFo0Mck-Bdz6Hnr</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2534293400</pqid></control><display><type>article</type><title>Impact of Advance Control on Microturbine Generation System Performance</title><source>Publicly Available Content Database</source><creator>Hussin, Ahmad Kamil Mat ; Wanik, Mohd Zamri Che</creator><creatorcontrib>Hussin, Ahmad Kamil Mat ; Wanik, Mohd Zamri Che</creatorcontrib><description>Advance control employed in microturbine generation system (MTGS) is expected to improve its performance in responding to grid faults. This paper compares the effect of advance control of MTGS power conversion topology on the performance in riding through the grid faults. The analysis and investigation study through simulation shows there is no significant different on MTGS output performance even advance control is employed for its rectifier.</description><identifier>ISSN: 1755-1315</identifier><identifier>ISSN: 1755-1307</identifier><identifier>EISSN: 1755-1315</identifier><identifier>DOI: 10.1088/1755-1315/16/1/012018</identifier><language>eng</language><publisher>Bristol: IOP Publishing</publisher><subject>Control systems ; Earth ; Energy conversion ; Faults ; Rectifiers ; Riding ; Simulation ; Topology</subject><ispartof>IOP conference series. Earth and environmental science, 2013-01, Vol.16 (1), p.1-4</ispartof><rights>2013. This work is published under http://creativecommons.org/licenses/by/3.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c342t-c3d25c72d76a723aa1b5be2915975f840a4a18119a295fbacbd55c8d5003f47a3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.proquest.com/docview/2534293400?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>314,777,781,25734,27905,27906,36993,36994,44571</link.rule.ids></links><search><creatorcontrib>Hussin, Ahmad Kamil Mat</creatorcontrib><creatorcontrib>Wanik, Mohd Zamri Che</creatorcontrib><title>Impact of Advance Control on Microturbine Generation System Performance</title><title>IOP conference series. Earth and environmental science</title><description>Advance control employed in microturbine generation system (MTGS) is expected to improve its performance in responding to grid faults. This paper compares the effect of advance control of MTGS power conversion topology on the performance in riding through the grid faults. The analysis and investigation study through simulation shows there is no significant different on MTGS output performance even advance control is employed for its rectifier.</description><subject>Control systems</subject><subject>Earth</subject><subject>Energy conversion</subject><subject>Faults</subject><subject>Rectifiers</subject><subject>Riding</subject><subject>Simulation</subject><subject>Topology</subject><issn>1755-1315</issn><issn>1755-1307</issn><issn>1755-1315</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><recordid>eNqFUcFKxDAQDaLguvoJQsGLl7WZpJOkx2XRdWFFQT2HNE2hS9usSSvs39uyIuLFy8zwePOYeY-Qa6B3QJVKQSIugAOmIFJIKTAK6oTMfvDTX_M5uYhxR6mQGc9nZL1p98b2ia-SZflpOuuSle_64JvEd8lTbYPvh1DUnUvWrnPB9PWIvx5i79rkxYXKh3bauiRnlWmiu_ruc_L-cP-2elxsn9eb1XK7sDxj_VhLhlayUgojGTcGCiwcywFziZXKqMkMKIDcsByrwtiiRLSqREp5lUnD5-T2qLsP_mNwsddtHa1rGtM5P0QNUgmQkmb0fyoKobhArkbqzR_qzg-hGx_RDMfDc57RSRCPrNGUGIOr9D7UrQkHDVRPSejJZT25rEFo0Mck-Bdz6Hnr</recordid><startdate>20130101</startdate><enddate>20130101</enddate><creator>Hussin, Ahmad Kamil Mat</creator><creator>Wanik, Mohd Zamri Che</creator><general>IOP Publishing</general><scope>AAYXX</scope><scope>CITATION</scope><scope>ABUWG</scope><scope>AEUYN</scope><scope>AFKRA</scope><scope>ATCPS</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BHPHI</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>GNUQQ</scope><scope>HCIFZ</scope><scope>PATMY</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PYCSY</scope><scope>7QH</scope><scope>7UA</scope><scope>C1K</scope><scope>F1W</scope><scope>H95</scope><scope>H97</scope><scope>L.G</scope><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope><scope>H8D</scope><scope>KR7</scope><scope>L7M</scope></search><sort><creationdate>20130101</creationdate><title>Impact of Advance Control on Microturbine Generation System Performance</title><author>Hussin, Ahmad Kamil Mat ; Wanik, Mohd Zamri Che</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c342t-c3d25c72d76a723aa1b5be2915975f840a4a18119a295fbacbd55c8d5003f47a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Control systems</topic><topic>Earth</topic><topic>Energy conversion</topic><topic>Faults</topic><topic>Rectifiers</topic><topic>Riding</topic><topic>Simulation</topic><topic>Topology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hussin, Ahmad Kamil Mat</creatorcontrib><creatorcontrib>Wanik, Mohd Zamri Che</creatorcontrib><collection>CrossRef</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest One Sustainability</collection><collection>ProQuest Central</collection><collection>Agricultural &amp; Environmental Science Collection</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>ProQuest Natural Science Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>ProQuest Central Student</collection><collection>SciTech Premium Collection</collection><collection>Environmental Science Database</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Environmental Science Collection</collection><collection>Aqualine</collection><collection>Water Resources Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ASFA: Aquatic Sciences and Fisheries Abstracts</collection><collection>Aquatic Science &amp; Fisheries Abstracts (ASFA) 1: Biological Sciences &amp; Living Resources</collection><collection>Aquatic Science &amp; Fisheries Abstracts (ASFA) 3: Aquatic Pollution &amp; Environmental Quality</collection><collection>Aquatic Science &amp; Fisheries Abstracts (ASFA) Professional</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>IOP conference series. Earth and environmental science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hussin, Ahmad Kamil Mat</au><au>Wanik, Mohd Zamri Che</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Impact of Advance Control on Microturbine Generation System Performance</atitle><jtitle>IOP conference series. Earth and environmental science</jtitle><date>2013-01-01</date><risdate>2013</risdate><volume>16</volume><issue>1</issue><spage>1</spage><epage>4</epage><pages>1-4</pages><issn>1755-1315</issn><issn>1755-1307</issn><eissn>1755-1315</eissn><abstract>Advance control employed in microturbine generation system (MTGS) is expected to improve its performance in responding to grid faults. This paper compares the effect of advance control of MTGS power conversion topology on the performance in riding through the grid faults. The analysis and investigation study through simulation shows there is no significant different on MTGS output performance even advance control is employed for its rectifier.</abstract><cop>Bristol</cop><pub>IOP Publishing</pub><doi>10.1088/1755-1315/16/1/012018</doi><tpages>4</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1755-1315
ispartof IOP conference series. Earth and environmental science, 2013-01, Vol.16 (1), p.1-4
issn 1755-1315
1755-1307
1755-1315
language eng
recordid cdi_proquest_miscellaneous_1786177040
source Publicly Available Content Database
subjects Control systems
Earth
Energy conversion
Faults
Rectifiers
Riding
Simulation
Topology
title Impact of Advance Control on Microturbine Generation System Performance
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-17T15%3A18%3A30IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Impact%20of%20Advance%20Control%20on%20Microturbine%20Generation%20System%20Performance&rft.jtitle=IOP%20conference%20series.%20Earth%20and%20environmental%20science&rft.au=Hussin,%20Ahmad%20Kamil%20Mat&rft.date=2013-01-01&rft.volume=16&rft.issue=1&rft.spage=1&rft.epage=4&rft.pages=1-4&rft.issn=1755-1315&rft.eissn=1755-1315&rft_id=info:doi/10.1088/1755-1315/16/1/012018&rft_dat=%3Cproquest_cross%3E1566836538%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c342t-c3d25c72d76a723aa1b5be2915975f840a4a18119a295fbacbd55c8d5003f47a3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2534293400&rft_id=info:pmid/&rfr_iscdi=true