Loading…
A Novel Method of High Sensitive Determination of Prednisolone on Renewable Mercury Film Silver Based Electrode
Fast and sensitive method of prednisolone determination at renewable mercury film electrode using differential pulse adsorptive stripping voltammetry (DPAdSV) was successfully developed. The effects of various factors such as: preconcentration potential and time, pulse height, step potential and sup...
Saved in:
Published in: | Electroanalysis (New York, N.Y.) N.Y.), 2016-02, Vol.28 (2), p.394-400 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c3602-c8967cc59887a5e94844ecfa503fb2807780dbf65663906b8f32063a2e8abfb23 |
---|---|
cites | cdi_FETCH-LOGICAL-c3602-c8967cc59887a5e94844ecfa503fb2807780dbf65663906b8f32063a2e8abfb23 |
container_end_page | 400 |
container_issue | 2 |
container_start_page | 394 |
container_title | Electroanalysis (New York, N.Y.) |
container_volume | 28 |
creator | Smajdor, Joanna Piech, Robert Paczosa-Bator, Beata |
description | Fast and sensitive method of prednisolone determination at renewable mercury film electrode using differential pulse adsorptive stripping voltammetry (DPAdSV) was successfully developed. The effects of various factors such as: preconcentration potential and time, pulse height, step potential and supporting electrolyte composition were optimized. A linear voltammetric response for analyte was obtained in the concentration range from 0.05 µmol L−1 (18 µg L−1) to 2.25 µmol L−1 (0.81 mg L−1), with a detection limit of 0.01 µmol L−1 for preconcentration time of 20 s. Repeatability of method was determined as RSD % for prednisolone concentration of 0.04 µmol L−1 as 1.6 % (n=9). The proposed method was successfully applied and validated by recovery parameter of prednisolone in simulated sample and pharmaceutical product. |
doi_str_mv | 10.1002/elan.201500262 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1800484252</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1800484252</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3602-c8967cc59887a5e94844ecfa503fb2807780dbf65663906b8f32063a2e8abfb23</originalsourceid><addsrcrecordid>eNqFkMFP2zAUhyM0JBjsytnHXdI924ljHztoC6gEBJt2tBznBby5MdhpWf97UnVC3HZ6fs_f9zv8suyMwoQCsG_oTT9hQMtxEewgO6Ylo3lBQX0a31BADlxVR9nnlH4DgBKFOs7ClNRhg57c4PAUWhI6cuken8gD9skNboPkAgeMK9ebwYV-938Xse1dCj70SMbTPfb4ahqPY0a067glc-dX5MH5DUby3SRsycyjHWJo8TQ77IxP-OXfPMl-zmc_zi_z5e3i6ny6zC0XwHIrlaisLZWUlSlRFbIo0HamBN41TEJVSWibTpRCcAWikR1nILhhKE0zEvwk-7rPfY7hZY1p0CuXLPqxIwzrpKkEGENZuUMne9TGkFLETj9HtzJxqynoXbN616x-b3YU1F54dR63_6H1bDmtP7r53nVpwL_vrol_tKh4Vepf9UJfL-eL-qJmmvI3syqMHQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1800484252</pqid></control><display><type>article</type><title>A Novel Method of High Sensitive Determination of Prednisolone on Renewable Mercury Film Silver Based Electrode</title><source>Wiley-Blackwell Read & Publish Collection</source><creator>Smajdor, Joanna ; Piech, Robert ; Paczosa-Bator, Beata</creator><creatorcontrib>Smajdor, Joanna ; Piech, Robert ; Paczosa-Bator, Beata</creatorcontrib><description>Fast and sensitive method of prednisolone determination at renewable mercury film electrode using differential pulse adsorptive stripping voltammetry (DPAdSV) was successfully developed. The effects of various factors such as: preconcentration potential and time, pulse height, step potential and supporting electrolyte composition were optimized. A linear voltammetric response for analyte was obtained in the concentration range from 0.05 µmol L−1 (18 µg L−1) to 2.25 µmol L−1 (0.81 mg L−1), with a detection limit of 0.01 µmol L−1 for preconcentration time of 20 s. Repeatability of method was determined as RSD % for prednisolone concentration of 0.04 µmol L−1 as 1.6 % (n=9). The proposed method was successfully applied and validated by recovery parameter of prednisolone in simulated sample and pharmaceutical product.</description><identifier>ISSN: 1040-0397</identifier><identifier>EISSN: 1521-4109</identifier><identifier>DOI: 10.1002/elan.201500262</identifier><language>eng</language><publisher>Weinheim: WILEY-VCH Verlag</publisher><subject>Composition effects ; Concentration (composition) ; Electrodes ; Electrolytes ; mercury film electrode ; Prednisolone ; Reproducibility ; Simulation ; steroid determination ; Stripping ; voltammetry</subject><ispartof>Electroanalysis (New York, N.Y.), 2016-02, Vol.28 (2), p.394-400</ispartof><rights>2016 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3602-c8967cc59887a5e94844ecfa503fb2807780dbf65663906b8f32063a2e8abfb23</citedby><cites>FETCH-LOGICAL-c3602-c8967cc59887a5e94844ecfa503fb2807780dbf65663906b8f32063a2e8abfb23</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Smajdor, Joanna</creatorcontrib><creatorcontrib>Piech, Robert</creatorcontrib><creatorcontrib>Paczosa-Bator, Beata</creatorcontrib><title>A Novel Method of High Sensitive Determination of Prednisolone on Renewable Mercury Film Silver Based Electrode</title><title>Electroanalysis (New York, N.Y.)</title><addtitle>Electroanalysis</addtitle><description>Fast and sensitive method of prednisolone determination at renewable mercury film electrode using differential pulse adsorptive stripping voltammetry (DPAdSV) was successfully developed. The effects of various factors such as: preconcentration potential and time, pulse height, step potential and supporting electrolyte composition were optimized. A linear voltammetric response for analyte was obtained in the concentration range from 0.05 µmol L−1 (18 µg L−1) to 2.25 µmol L−1 (0.81 mg L−1), with a detection limit of 0.01 µmol L−1 for preconcentration time of 20 s. Repeatability of method was determined as RSD % for prednisolone concentration of 0.04 µmol L−1 as 1.6 % (n=9). The proposed method was successfully applied and validated by recovery parameter of prednisolone in simulated sample and pharmaceutical product.</description><subject>Composition effects</subject><subject>Concentration (composition)</subject><subject>Electrodes</subject><subject>Electrolytes</subject><subject>mercury film electrode</subject><subject>Prednisolone</subject><subject>Reproducibility</subject><subject>Simulation</subject><subject>steroid determination</subject><subject>Stripping</subject><subject>voltammetry</subject><issn>1040-0397</issn><issn>1521-4109</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><recordid>eNqFkMFP2zAUhyM0JBjsytnHXdI924ljHztoC6gEBJt2tBznBby5MdhpWf97UnVC3HZ6fs_f9zv8suyMwoQCsG_oTT9hQMtxEewgO6Ylo3lBQX0a31BADlxVR9nnlH4DgBKFOs7ClNRhg57c4PAUWhI6cuken8gD9skNboPkAgeMK9ebwYV-938Xse1dCj70SMbTPfb4ahqPY0a067glc-dX5MH5DUby3SRsycyjHWJo8TQ77IxP-OXfPMl-zmc_zi_z5e3i6ny6zC0XwHIrlaisLZWUlSlRFbIo0HamBN41TEJVSWibTpRCcAWikR1nILhhKE0zEvwk-7rPfY7hZY1p0CuXLPqxIwzrpKkEGENZuUMne9TGkFLETj9HtzJxqynoXbN616x-b3YU1F54dR63_6H1bDmtP7r53nVpwL_vrol_tKh4Vepf9UJfL-eL-qJmmvI3syqMHQ</recordid><startdate>201602</startdate><enddate>201602</enddate><creator>Smajdor, Joanna</creator><creator>Piech, Robert</creator><creator>Paczosa-Bator, Beata</creator><general>WILEY-VCH Verlag</general><general>WILEY‐VCH Verlag</general><scope>BSCLL</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope></search><sort><creationdate>201602</creationdate><title>A Novel Method of High Sensitive Determination of Prednisolone on Renewable Mercury Film Silver Based Electrode</title><author>Smajdor, Joanna ; Piech, Robert ; Paczosa-Bator, Beata</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3602-c8967cc59887a5e94844ecfa503fb2807780dbf65663906b8f32063a2e8abfb23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Composition effects</topic><topic>Concentration (composition)</topic><topic>Electrodes</topic><topic>Electrolytes</topic><topic>mercury film electrode</topic><topic>Prednisolone</topic><topic>Reproducibility</topic><topic>Simulation</topic><topic>steroid determination</topic><topic>Stripping</topic><topic>voltammetry</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Smajdor, Joanna</creatorcontrib><creatorcontrib>Piech, Robert</creatorcontrib><creatorcontrib>Paczosa-Bator, Beata</creatorcontrib><collection>Istex</collection><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Electroanalysis (New York, N.Y.)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Smajdor, Joanna</au><au>Piech, Robert</au><au>Paczosa-Bator, Beata</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A Novel Method of High Sensitive Determination of Prednisolone on Renewable Mercury Film Silver Based Electrode</atitle><jtitle>Electroanalysis (New York, N.Y.)</jtitle><addtitle>Electroanalysis</addtitle><date>2016-02</date><risdate>2016</risdate><volume>28</volume><issue>2</issue><spage>394</spage><epage>400</epage><pages>394-400</pages><issn>1040-0397</issn><eissn>1521-4109</eissn><abstract>Fast and sensitive method of prednisolone determination at renewable mercury film electrode using differential pulse adsorptive stripping voltammetry (DPAdSV) was successfully developed. The effects of various factors such as: preconcentration potential and time, pulse height, step potential and supporting electrolyte composition were optimized. A linear voltammetric response for analyte was obtained in the concentration range from 0.05 µmol L−1 (18 µg L−1) to 2.25 µmol L−1 (0.81 mg L−1), with a detection limit of 0.01 µmol L−1 for preconcentration time of 20 s. Repeatability of method was determined as RSD % for prednisolone concentration of 0.04 µmol L−1 as 1.6 % (n=9). The proposed method was successfully applied and validated by recovery parameter of prednisolone in simulated sample and pharmaceutical product.</abstract><cop>Weinheim</cop><pub>WILEY-VCH Verlag</pub><doi>10.1002/elan.201500262</doi><tpages>7</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1040-0397 |
ispartof | Electroanalysis (New York, N.Y.), 2016-02, Vol.28 (2), p.394-400 |
issn | 1040-0397 1521-4109 |
language | eng |
recordid | cdi_proquest_miscellaneous_1800484252 |
source | Wiley-Blackwell Read & Publish Collection |
subjects | Composition effects Concentration (composition) Electrodes Electrolytes mercury film electrode Prednisolone Reproducibility Simulation steroid determination Stripping voltammetry |
title | A Novel Method of High Sensitive Determination of Prednisolone on Renewable Mercury Film Silver Based Electrode |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T09%3A00%3A20IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20Novel%20Method%20of%20High%20Sensitive%20Determination%20of%20Prednisolone%20on%20Renewable%20Mercury%20Film%20Silver%20Based%20Electrode&rft.jtitle=Electroanalysis%20(New%20York,%20N.Y.)&rft.au=Smajdor,%20Joanna&rft.date=2016-02&rft.volume=28&rft.issue=2&rft.spage=394&rft.epage=400&rft.pages=394-400&rft.issn=1040-0397&rft.eissn=1521-4109&rft_id=info:doi/10.1002/elan.201500262&rft_dat=%3Cproquest_cross%3E1800484252%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c3602-c8967cc59887a5e94844ecfa503fb2807780dbf65663906b8f32063a2e8abfb23%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1800484252&rft_id=info:pmid/&rfr_iscdi=true |