Loading…
The attachment process of rocket‐triggered lightning dart‐stepped leaders
Time‐correlated 1.54 µs high‐speed video frames, channel‐base current and current derivative (dI/dt), and electric field derivative (dE/dt) measurements are used to analyze the attachment process of triggered lightning dart‐stepped leaders. Lengths, speeds, and durations of the upward‐connecting pos...
Saved in:
Published in: | Journal of geophysical research. Atmospheres 2016-01, Vol.121 (2), p.853-871 |
---|---|
Main Authors: | , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Time‐correlated 1.54 µs high‐speed video frames, channel‐base current and current derivative (dI/dt), and electric field derivative (dE/dt) measurements are used to analyze the attachment process of triggered lightning dart‐stepped leaders. Lengths, speeds, and durations of the upward‐connecting positive leaders propagating from the launching structure are measured and calculated. The “leader burst” occurring immediately preceding the dE/dt slow front is demonstrated to be a distinctly different process from the preceding downward dart‐stepped leader steps and is associated with the fast increase in channel‐base current due to the initial interactions of the downward and upward leader streamer zones. Locations of the leader burst pulses are found to occur within or immediately above the connection region. Pulses superimposed on the dE/dt slow front are shown to occur after the initial connection between the downward and upward leaders and are associated with kiloampere‐scale increases in the channel‐base current. Subsequent fast‐transition pulses are found to produce multiple kiloampere‐scale increases in the channel‐base current. Observed time delays between dE/dt and dI/dt peaks for slow front and fast‐transition pulses confirm the existence of an elevated junction point between the downward and upward leaders. Average downward current wave speeds for fast‐transition pulses are found to be a factor of 2 to 2.5 faster than those for slow‐front pulses. For 51 dart‐stepped leader events, the average total duration of the attachment process, starting with the initial fast current increase and ending with the peak of the final dI/dt fast‐transition pulse, is measured to be 1.77 µs.
Key Points
In‐depth analyses of the attachment process of triggered lightning dart‐stepped leaders
Lengths, speeds, and durations of the upward connecting positive leader are measured and calculated
Observed time delay between dE/dt and dI/dt peaks confirms existence of elevated junction point |
---|---|
ISSN: | 2169-897X 2169-8996 |
DOI: | 10.1002/2015JD024269 |