Liquid chromatography/photodiode array detection for determination of strychnine in blood: a fatal case report
An original liquid chromatography method with photodiode-array detection (DAD) is presented for the determination of strychnine in blood. This sensitive method allows the use of only 0.1ml of sample. The strychnine was isolated from blood using a liquid–liquid extraction procedure and chloroquine as...
Saved in:
Published in: | Forensic science international 2004-04, Vol.141 (1), p.17-21 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | An original liquid chromatography method with photodiode-array detection (DAD) is presented for the determination of strychnine in blood. This sensitive method allows the use of only 0.1ml of sample. The strychnine was isolated from blood using a liquid–liquid extraction procedure and chloroquine as an internal standard. The limits of detection (LOD) and quantification were 0.06 and 0.5mg/l, respectively. The recovery was 94% and the coefficients of variation (CV) ranged from 5.9 to 10.8%. A fatal case of strychnine poisoning is presented, with a lethal blood concentration of 25mg/l. |
---|---|
ISSN: | 0379-0738 1872-6283 |
DOI: | 10.1016/j.forsciint.2003.12.010 |