EChO payload electronics architecture and SW design
EChO is a three-modules (VNIR, SWIR, MWIR), highly integrated spectrometer, covering the wavelength range from 0.55 μ m to 11.0 μ m . The baseline design includes the goal wavelength extension to 0.4 μ m while an optional LWIR module extends the range to the goal wavelength of 16.0 μ m . An Instrume...
Saved in:
Published in: | Experimental astronomy 2015-12, Vol.40 (2-3), p.813-839 |
---|---|
Main Authors: | , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | EChO is a three-modules (VNIR, SWIR, MWIR), highly integrated spectrometer, covering the wavelength range from 0.55
μ
m
to 11.0
μ
m
. The baseline design includes the goal wavelength extension to 0.4
μ
m
while an optional LWIR module extends the range to the goal wavelength of 16.0
μ
m
. An Instrument Control Unit (ICU) is foreseen as the main electronic subsystem interfacing the spacecraft and collecting data from all the payload spectrometers modules. ICU is in charge of two main tasks: the overall payload control (
Instrument Control Function
) and the housekeepings and scientific data digital processing (
Data Processing Function
), including the lossless compression prior to store the science data to the Solid State Mass Memory of the Spacecraft. These two main tasks are accomplished thanks to the Payload On Board Software (P-OBSW) running on the ICU CPUs. |
---|---|
ISSN: | 0922-6435 1572-9508 |
DOI: | 10.1007/s10686-014-9384-3 |