The impacts of daytime external envelope heat gain/storage on the nighttime cooling load and the related mitigation measures in a bedroom in the subtropics

•A simulation study on nighttime load characteristics in a bedroom is reported.•The impacts of daytime heat gain on nighttime bedroom cooling load were studied.•The west facing external wall contributed the most to nighttime cooling load.•Adding an air gap in the external wall can help reduce the ni...

Full description

Saved in:
Bibliographic Details
Published in:Energy and buildings 2016-04, Vol.118, p.70-81
Main Authors: Du, Jing, Chan, Mingyin, Pan, Dongmei, Shang, Libin, Deng, Shiming
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:•A simulation study on nighttime load characteristics in a bedroom is reported.•The impacts of daytime heat gain on nighttime bedroom cooling load were studied.•The west facing external wall contributed the most to nighttime cooling load.•Adding an air gap in the external wall can help reduce the nighttime cooling load.•Ventilating and adhering aluminum foil in the air gap can further reduce load In the subtropics, air conditioning (A/C) for a bedroom in residential buildings commonly serves to provide an appropriate indoor thermal environment at nighttime for sleeping. During daytime when A/C is not provided, a large amount of thermal energy can be stored in the thermal mass in its envelope components, in particularly its external walls. The energy stored would be gradually released, contributing significantly to the total space cooling load in the bedroom at nighttime. Therefore, this paper reports a simulation study on the impacts of daytime external envelope heat gain/storage on the nighttime cooling load in a hypothetic west-facing bedroom and the related mitigation measures in the subtropical Hong Kong. The study results showed that, among all envelope components, the west-facing external wall contributed most significantly to the total nighttime cooling load, because of its direct exposure to solar radiation, thus the heat gain and storage in its thermal mass. In addition, adding an air gap in the west-facing external wall can reduce remarkably the hourly total nighttime cooling load for the first hour (21:00–22:00) and the total cooling load for the 10-h A/C period. However, while varying the width of either the air gap or inside/outside concrete layers would not reduce cooling load further, ventilating mechanically the air gap can further increase the cooling load reduction and improve the flatness of load variation profile at the expense of consuming additional electrical energy. Finally, adhering aluminum foil to both sides of the air gap can further remarkably reduce nighttime cooling load, and improve the flatness of the load variation profile.
ISSN:0378-7788
DOI:10.1016/j.enbuild.2016.02.010