Loading…

Determination of phentermine, N-hydroxyphentermine and mephentermine in urine using dilute and shoot liquid chromatography–tandem mass spectrometry

•We developed a reliable method for determination of phentermine, N-hydroxyphentermine and mephentermine in urine using LC–MS/MS.•The method was validated and its applicability was confirmed by analysis of real urine samples.•The method is considered to be effective for differentiating whether PT or...

Full description

Saved in:
Bibliographic Details
Published in:Journal of chromatography. B, Analytical technologies in the biomedical and life sciences Analytical technologies in the biomedical and life sciences, 2016-09, Vol.1029-1030, p.22-27
Main Authors: Choi, Yun Jeong, Sim, Arum, Kim, Min Kyung, Suh, Sunglll, In, Moon Kyo, Kim, Jin Young
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:•We developed a reliable method for determination of phentermine, N-hydroxyphentermine and mephentermine in urine using LC–MS/MS.•The method was validated and its applicability was confirmed by analysis of real urine samples.•The method is considered to be effective for differentiating whether PT or MPT is ingested. Nonmedical use of prescription stimulants such as phentermine (PT) has been regulated by law enforcement authorities due to its euphorigenic and relaxing effects. Due to high potential for its abuse, reliable analytical methods were required to detect and identify PT and its metabolite in biological samples. Thus a dilute and shoot liquid chromatography–tandem mass spectrometric (LC–MS/MS) method was developed and validated for simultaneous determination of PT, N-hydroxyphentermine (NHOPT) and mephentermine (MPT) in urine. A 5μL aliquot of diluted urine was injected into the LC–MS/MS system. Chromatographic separation was performed by reversed-phase C18 column with gradient elution for all analytes within 5min. Identification and quantification were based on multiple reaction monitoring (MRM) detection. Linear least-squares regression with a 1/x2 weighting factor was used to generate a calibration curve and the assay was linear from 50 to 15000ng/mL (PT and MPT) and 5 to 750ng/mL (NHOPT). The intra- and inter-day precisions were within 8.9% while the intra- and inter-day accuracies ranged from −6.2% to 11.2%. The limits of quantification were 3.5ng/mL (PT), 1.5ng/mL (NHOPT) and 1.0ng/mL (MPT). Method validation requirements for selectivity, dilution integrity, matrix effect and stability were satisfied. The applicability of the developed method was examined by analyzing urine samples from drug abusers.
ISSN:1570-0232
1873-376X