Loading…

Ultrasound for the evaluation of soft tissue foreign bodies before and after the addition of fluid to the surrounding interstitial space in a cadaveric model

Abstract Background Point of care ultrasound may be used to facilitate foreign body (FB) localization and removal. We hypothesized that injection of normal saline adjacent to an FB may make it easier to detect. Methods The study was performed on one embalmed human cadaver. Potential FB sites were cr...

Full description

Saved in:
Bibliographic Details
Published in:The American journal of emergency medicine 2016-09, Vol.34 (9), p.1779-1782
Main Authors: Saul, Turandot, MD, Siadecki, Sebastian D., MD, Rose, Gabriel, DO, Berkowitz, Rachel, MD, Drake, Aaran B., MD, Delone, Noah, MD, Avitabile, Nicholas, DO
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Abstract Background Point of care ultrasound may be used to facilitate foreign body (FB) localization and removal. We hypothesized that injection of normal saline adjacent to an FB may make it easier to detect. Methods The study was performed on one embalmed human cadaver. Potential FB sites were created of wood (24), metal (24) and null (24). Two sonographers evaluated each of the 72 sites both before and after a 25-gauge needle was inserted into each incision and 3 cc of normal saline was injected. Accuracy, sensitivity and specificity were calculated both pre- and post-injection of normal saline. Binomial tests were used to determine the statistical significance of FB detection pre- and post-injection. A two-tailed student's t test was used to determine if there was a statistically significant difference between the two methods. Results Pre-injection, 116/144 (81%, p = < 0.001) of the interpretations were correct in their assessment, with a sensitivity of 81% (95% CI 72% - 88%) and a specificity of 79% (95% CI 65% - 90%). Post-injection, 119/144 (83%, p = < 0.001) of these interpretations were correct in their assessment of whether or not an FB was present, with a sensitivity of 85% (95% CI 77% - 92%,) and a specificity of 77% (95% CI 63% - 88%). This difference was not significant (p = 0.08, CI − 0.04 to 0.01). Discussion Ultrasound was reasonably accurate, sensitive and specific in identifying 1 cm metal and wood FBs. While accuracy and sensitivity did improve after normal saline injection, this difference was not significant.
ISSN:0735-6757
1532-8171
DOI:10.1016/j.ajem.2016.06.004