Loading…

Robotic hysterectomy and lymphadenectomy for endometrial cancer: technical aspects and details of success—the Ohio State University method

Limited data exist regarding description and technical aspects of operating room (OR) set-up, port placement, and instrument selection for robotic gynecologic oncology procedures. The objective of this manuscript and video is to show the established protocol steps at our institution for setting up a...

Full description

Saved in:
Bibliographic Details
Published in:Journal of robotic surgery 2008-07, Vol.2 (2), p.71-76
Main Authors: Seamon, Leigh G., Cohn, David E., Valmadre, Sue, Richardson, Debra L., Jayjohn, Lynda A., Jenson, Cathy, Lee, Keri, Travis, Janet, Nickerson, Edward, Fowler, Jeffrey M.
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c372t-a3565c14f17786f0733dc27e396fd127d2f709ed61d04ce3d71d8bbabd86c3
cites
container_end_page 76
container_issue 2
container_start_page 71
container_title Journal of robotic surgery
container_volume 2
creator Seamon, Leigh G.
Cohn, David E.
Valmadre, Sue
Richardson, Debra L.
Jayjohn, Lynda A.
Jenson, Cathy
Lee, Keri
Travis, Janet
Nickerson, Edward
Fowler, Jeffrey M.
description Limited data exist regarding description and technical aspects of operating room (OR) set-up, port placement, and instrument selection for robotic gynecologic oncology procedures. The objective of this manuscript and video is to show the established protocol steps at our institution for setting up a robotic hysterectomy and comprehensive lymphadenectomy (dVH-LND) for endometrial cancer. OR preparation of the robotic system prior to patient entry and set-up is demonstrated. The patient is placed in low-lithotomy on an OR table that includes a beanbag and a gel pad that is taped securely for additional stabilization. The arms/shoulders are padded to decrease injury risk and the chest is padded with foam to protect the patient from robotic arm movements. The patient is prepped widely from mid-nipple line to beyond the mid-axillary line and draped. Vaginal instrumentation includes an end-to-end anstomosis (EEA) sizer and pneumo-occluder. Port preferences, placement, and instrument selections are also demonstrated. Using a four-arm robotic system, the camera port is placed midline, approximately 20–27 cm above the pubic symphysis. Robotic ports (RP) for arms #2 and #3 are placed 8–12 cm left lateral to and 15–30° down from the camera port at approximately the level of the umbilicus. A 12 mm laparoscopic assistant port and RP#1 are placed 8–12 cm right lateral to the umbilicus and in the same position as RP#3 and #2, respectively. An additional 5 mm port is placed beneath the costal margin. This method requires only a single docking and one instrument exchange. The bedside assistant stands on the right and is essential for exposure, manipulating the uterus, passage of suture, and troubleshooting potential problems. In addition, port closure technique and methods to remove a large uterus are discussed. We have successfully completed over 70 dVH-LND for endometrial cancer using this protocol. Establishing a systematic routine for OR set-up and port placement in robotic surgery for gynecologic oncology is important for patient safety and allows for efficient use of OR time.
doi_str_mv 10.1007/s11701-008-0090-x
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1821793046</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1821793046</sourcerecordid><originalsourceid>FETCH-LOGICAL-c372t-a3565c14f17786f0733dc27e396fd127d2f709ed61d04ce3d71d8bbabd86c3</originalsourceid><addsrcrecordid>eNp1kc1qFTEYhoNYbK1egBsJuHEzNl9yZjLjTop_UChUXYdM8o2TMpMck4x0dl6Ay15hr8TUc1qh4CIkfHneN4GHkBfA3gBj8iQBSAYVY21ZHauuHpEjaBtR8U0Hj-_PrTgkT1O6ZKyWtYAn5JDLRsiaiSPy-yL0ITtDxzVljGhymFeqvaXTOm9HbdHvZ0OIFL0NM-bo9ESN9gbjW5rRjN6ZMtFpW9j0N20xazclGgaaFmMwpZtf13lEej66QL9knZF-8-4nxuTySkvpGOwzcjDoKeHz_X5MLj68_3r6qTo7__j59N1ZZYTkudKibmoDmwGkbJuBSSGs4RJF1wwWuLR8kKxD24BlG4PCSrBt3-veto0Rx-T1rnQbw48FU1azSwanSXsMS1LQcpCdYJumoK8eoJdhib58TfEOWgmig65QsKNMDClFHNQ2ulnHVQFTt57UzpMqntStJ3VVMi_3zUs_o71P3IkpAN8BqVz57xj_Pf3_1j-snaIH</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2918713919</pqid></control><display><type>article</type><title>Robotic hysterectomy and lymphadenectomy for endometrial cancer: technical aspects and details of success—the Ohio State University method</title><source>Springer Nature</source><creator>Seamon, Leigh G. ; Cohn, David E. ; Valmadre, Sue ; Richardson, Debra L. ; Jayjohn, Lynda A. ; Jenson, Cathy ; Lee, Keri ; Travis, Janet ; Nickerson, Edward ; Fowler, Jeffrey M.</creator><creatorcontrib>Seamon, Leigh G. ; Cohn, David E. ; Valmadre, Sue ; Richardson, Debra L. ; Jayjohn, Lynda A. ; Jenson, Cathy ; Lee, Keri ; Travis, Janet ; Nickerson, Edward ; Fowler, Jeffrey M.</creatorcontrib><description>Limited data exist regarding description and technical aspects of operating room (OR) set-up, port placement, and instrument selection for robotic gynecologic oncology procedures. The objective of this manuscript and video is to show the established protocol steps at our institution for setting up a robotic hysterectomy and comprehensive lymphadenectomy (dVH-LND) for endometrial cancer. OR preparation of the robotic system prior to patient entry and set-up is demonstrated. The patient is placed in low-lithotomy on an OR table that includes a beanbag and a gel pad that is taped securely for additional stabilization. The arms/shoulders are padded to decrease injury risk and the chest is padded with foam to protect the patient from robotic arm movements. The patient is prepped widely from mid-nipple line to beyond the mid-axillary line and draped. Vaginal instrumentation includes an end-to-end anstomosis (EEA) sizer and pneumo-occluder. Port preferences, placement, and instrument selections are also demonstrated. Using a four-arm robotic system, the camera port is placed midline, approximately 20–27 cm above the pubic symphysis. Robotic ports (RP) for arms #2 and #3 are placed 8–12 cm left lateral to and 15–30° down from the camera port at approximately the level of the umbilicus. A 12 mm laparoscopic assistant port and RP#1 are placed 8–12 cm right lateral to the umbilicus and in the same position as RP#3 and #2, respectively. An additional 5 mm port is placed beneath the costal margin. This method requires only a single docking and one instrument exchange. The bedside assistant stands on the right and is essential for exposure, manipulating the uterus, passage of suture, and troubleshooting potential problems. In addition, port closure technique and methods to remove a large uterus are discussed. We have successfully completed over 70 dVH-LND for endometrial cancer using this protocol. Establishing a systematic routine for OR set-up and port placement in robotic surgery for gynecologic oncology is important for patient safety and allows for efficient use of OR time.</description><identifier>ISSN: 1863-2483</identifier><identifier>EISSN: 1863-2491</identifier><identifier>DOI: 10.1007/s11701-008-0090-x</identifier><identifier>PMID: 27637503</identifier><language>eng</language><publisher>London: Springer-Verlag</publisher><subject>Abdomen ; Cameras ; Cancer ; Endometrial cancer ; Hysterectomy ; Medicine ; Medicine &amp; Public Health ; Minimally Invasive Surgery ; Oncology ; Original Article ; Robot arms ; Robotic surgery ; Surgeons ; Surgery ; Troubleshooting ; Urology ; Uterus ; Vagina</subject><ispartof>Journal of robotic surgery, 2008-07, Vol.2 (2), p.71-76</ispartof><rights>Springer-Verlag London Ltd 2008</rights><rights>Springer-Verlag London Ltd 2008.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c372t-a3565c14f17786f0733dc27e396fd127d2f709ed61d04ce3d71d8bbabd86c3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/27637503$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Seamon, Leigh G.</creatorcontrib><creatorcontrib>Cohn, David E.</creatorcontrib><creatorcontrib>Valmadre, Sue</creatorcontrib><creatorcontrib>Richardson, Debra L.</creatorcontrib><creatorcontrib>Jayjohn, Lynda A.</creatorcontrib><creatorcontrib>Jenson, Cathy</creatorcontrib><creatorcontrib>Lee, Keri</creatorcontrib><creatorcontrib>Travis, Janet</creatorcontrib><creatorcontrib>Nickerson, Edward</creatorcontrib><creatorcontrib>Fowler, Jeffrey M.</creatorcontrib><title>Robotic hysterectomy and lymphadenectomy for endometrial cancer: technical aspects and details of success—the Ohio State University method</title><title>Journal of robotic surgery</title><addtitle>J Robotic Surg</addtitle><addtitle>J Robot Surg</addtitle><description>Limited data exist regarding description and technical aspects of operating room (OR) set-up, port placement, and instrument selection for robotic gynecologic oncology procedures. The objective of this manuscript and video is to show the established protocol steps at our institution for setting up a robotic hysterectomy and comprehensive lymphadenectomy (dVH-LND) for endometrial cancer. OR preparation of the robotic system prior to patient entry and set-up is demonstrated. The patient is placed in low-lithotomy on an OR table that includes a beanbag and a gel pad that is taped securely for additional stabilization. The arms/shoulders are padded to decrease injury risk and the chest is padded with foam to protect the patient from robotic arm movements. The patient is prepped widely from mid-nipple line to beyond the mid-axillary line and draped. Vaginal instrumentation includes an end-to-end anstomosis (EEA) sizer and pneumo-occluder. Port preferences, placement, and instrument selections are also demonstrated. Using a four-arm robotic system, the camera port is placed midline, approximately 20–27 cm above the pubic symphysis. Robotic ports (RP) for arms #2 and #3 are placed 8–12 cm left lateral to and 15–30° down from the camera port at approximately the level of the umbilicus. A 12 mm laparoscopic assistant port and RP#1 are placed 8–12 cm right lateral to the umbilicus and in the same position as RP#3 and #2, respectively. An additional 5 mm port is placed beneath the costal margin. This method requires only a single docking and one instrument exchange. The bedside assistant stands on the right and is essential for exposure, manipulating the uterus, passage of suture, and troubleshooting potential problems. In addition, port closure technique and methods to remove a large uterus are discussed. We have successfully completed over 70 dVH-LND for endometrial cancer using this protocol. Establishing a systematic routine for OR set-up and port placement in robotic surgery for gynecologic oncology is important for patient safety and allows for efficient use of OR time.</description><subject>Abdomen</subject><subject>Cameras</subject><subject>Cancer</subject><subject>Endometrial cancer</subject><subject>Hysterectomy</subject><subject>Medicine</subject><subject>Medicine &amp; Public Health</subject><subject>Minimally Invasive Surgery</subject><subject>Oncology</subject><subject>Original Article</subject><subject>Robot arms</subject><subject>Robotic surgery</subject><subject>Surgeons</subject><subject>Surgery</subject><subject>Troubleshooting</subject><subject>Urology</subject><subject>Uterus</subject><subject>Vagina</subject><issn>1863-2483</issn><issn>1863-2491</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><recordid>eNp1kc1qFTEYhoNYbK1egBsJuHEzNl9yZjLjTop_UChUXYdM8o2TMpMck4x0dl6Ay15hr8TUc1qh4CIkfHneN4GHkBfA3gBj8iQBSAYVY21ZHauuHpEjaBtR8U0Hj-_PrTgkT1O6ZKyWtYAn5JDLRsiaiSPy-yL0ITtDxzVljGhymFeqvaXTOm9HbdHvZ0OIFL0NM-bo9ESN9gbjW5rRjN6ZMtFpW9j0N20xazclGgaaFmMwpZtf13lEej66QL9knZF-8-4nxuTySkvpGOwzcjDoKeHz_X5MLj68_3r6qTo7__j59N1ZZYTkudKibmoDmwGkbJuBSSGs4RJF1wwWuLR8kKxD24BlG4PCSrBt3-veto0Rx-T1rnQbw48FU1azSwanSXsMS1LQcpCdYJumoK8eoJdhib58TfEOWgmig65QsKNMDClFHNQ2ulnHVQFTt57UzpMqntStJ3VVMi_3zUs_o71P3IkpAN8BqVz57xj_Pf3_1j-snaIH</recordid><startdate>20080701</startdate><enddate>20080701</enddate><creator>Seamon, Leigh G.</creator><creator>Cohn, David E.</creator><creator>Valmadre, Sue</creator><creator>Richardson, Debra L.</creator><creator>Jayjohn, Lynda A.</creator><creator>Jenson, Cathy</creator><creator>Lee, Keri</creator><creator>Travis, Janet</creator><creator>Nickerson, Edward</creator><creator>Fowler, Jeffrey M.</creator><general>Springer-Verlag</general><general>Springer Nature B.V</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>8FE</scope><scope>8FG</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>HCIFZ</scope><scope>K9.</scope><scope>L6V</scope><scope>M0S</scope><scope>M7S</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PTHSS</scope><scope>7X8</scope></search><sort><creationdate>20080701</creationdate><title>Robotic hysterectomy and lymphadenectomy for endometrial cancer: technical aspects and details of success—the Ohio State University method</title><author>Seamon, Leigh G. ; Cohn, David E. ; Valmadre, Sue ; Richardson, Debra L. ; Jayjohn, Lynda A. ; Jenson, Cathy ; Lee, Keri ; Travis, Janet ; Nickerson, Edward ; Fowler, Jeffrey M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c372t-a3565c14f17786f0733dc27e396fd127d2f709ed61d04ce3d71d8bbabd86c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Abdomen</topic><topic>Cameras</topic><topic>Cancer</topic><topic>Endometrial cancer</topic><topic>Hysterectomy</topic><topic>Medicine</topic><topic>Medicine &amp; Public Health</topic><topic>Minimally Invasive Surgery</topic><topic>Oncology</topic><topic>Original Article</topic><topic>Robot arms</topic><topic>Robotic surgery</topic><topic>Surgeons</topic><topic>Surgery</topic><topic>Troubleshooting</topic><topic>Urology</topic><topic>Uterus</topic><topic>Vagina</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Seamon, Leigh G.</creatorcontrib><creatorcontrib>Cohn, David E.</creatorcontrib><creatorcontrib>Valmadre, Sue</creatorcontrib><creatorcontrib>Richardson, Debra L.</creatorcontrib><creatorcontrib>Jayjohn, Lynda A.</creatorcontrib><creatorcontrib>Jenson, Cathy</creatorcontrib><creatorcontrib>Lee, Keri</creatorcontrib><creatorcontrib>Travis, Janet</creatorcontrib><creatorcontrib>Nickerson, Edward</creatorcontrib><creatorcontrib>Fowler, Jeffrey M.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>Materials Science &amp; Engineering Collection</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>ProQuest Engineering Collection</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>Engineering Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>Engineering Collection</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of robotic surgery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Seamon, Leigh G.</au><au>Cohn, David E.</au><au>Valmadre, Sue</au><au>Richardson, Debra L.</au><au>Jayjohn, Lynda A.</au><au>Jenson, Cathy</au><au>Lee, Keri</au><au>Travis, Janet</au><au>Nickerson, Edward</au><au>Fowler, Jeffrey M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Robotic hysterectomy and lymphadenectomy for endometrial cancer: technical aspects and details of success—the Ohio State University method</atitle><jtitle>Journal of robotic surgery</jtitle><stitle>J Robotic Surg</stitle><addtitle>J Robot Surg</addtitle><date>2008-07-01</date><risdate>2008</risdate><volume>2</volume><issue>2</issue><spage>71</spage><epage>76</epage><pages>71-76</pages><issn>1863-2483</issn><eissn>1863-2491</eissn><abstract>Limited data exist regarding description and technical aspects of operating room (OR) set-up, port placement, and instrument selection for robotic gynecologic oncology procedures. The objective of this manuscript and video is to show the established protocol steps at our institution for setting up a robotic hysterectomy and comprehensive lymphadenectomy (dVH-LND) for endometrial cancer. OR preparation of the robotic system prior to patient entry and set-up is demonstrated. The patient is placed in low-lithotomy on an OR table that includes a beanbag and a gel pad that is taped securely for additional stabilization. The arms/shoulders are padded to decrease injury risk and the chest is padded with foam to protect the patient from robotic arm movements. The patient is prepped widely from mid-nipple line to beyond the mid-axillary line and draped. Vaginal instrumentation includes an end-to-end anstomosis (EEA) sizer and pneumo-occluder. Port preferences, placement, and instrument selections are also demonstrated. Using a four-arm robotic system, the camera port is placed midline, approximately 20–27 cm above the pubic symphysis. Robotic ports (RP) for arms #2 and #3 are placed 8–12 cm left lateral to and 15–30° down from the camera port at approximately the level of the umbilicus. A 12 mm laparoscopic assistant port and RP#1 are placed 8–12 cm right lateral to the umbilicus and in the same position as RP#3 and #2, respectively. An additional 5 mm port is placed beneath the costal margin. This method requires only a single docking and one instrument exchange. The bedside assistant stands on the right and is essential for exposure, manipulating the uterus, passage of suture, and troubleshooting potential problems. In addition, port closure technique and methods to remove a large uterus are discussed. We have successfully completed over 70 dVH-LND for endometrial cancer using this protocol. Establishing a systematic routine for OR set-up and port placement in robotic surgery for gynecologic oncology is important for patient safety and allows for efficient use of OR time.</abstract><cop>London</cop><pub>Springer-Verlag</pub><pmid>27637503</pmid><doi>10.1007/s11701-008-0090-x</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1863-2483
ispartof Journal of robotic surgery, 2008-07, Vol.2 (2), p.71-76
issn 1863-2483
1863-2491
language eng
recordid cdi_proquest_miscellaneous_1821793046
source Springer Nature
subjects Abdomen
Cameras
Cancer
Endometrial cancer
Hysterectomy
Medicine
Medicine & Public Health
Minimally Invasive Surgery
Oncology
Original Article
Robot arms
Robotic surgery
Surgeons
Surgery
Troubleshooting
Urology
Uterus
Vagina
title Robotic hysterectomy and lymphadenectomy for endometrial cancer: technical aspects and details of success—the Ohio State University method
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-11T19%3A04%3A24IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Robotic%20hysterectomy%20and%20lymphadenectomy%20for%20endometrial%20cancer:%20technical%20aspects%20and%20details%20of%20success%E2%80%94the%20Ohio%20State%20University%20method&rft.jtitle=Journal%20of%20robotic%20surgery&rft.au=Seamon,%20Leigh%20G.&rft.date=2008-07-01&rft.volume=2&rft.issue=2&rft.spage=71&rft.epage=76&rft.pages=71-76&rft.issn=1863-2483&rft.eissn=1863-2491&rft_id=info:doi/10.1007/s11701-008-0090-x&rft_dat=%3Cproquest_cross%3E1821793046%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c372t-a3565c14f17786f0733dc27e396fd127d2f709ed61d04ce3d71d8bbabd86c3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2918713919&rft_id=info:pmid/27637503&rfr_iscdi=true