Thermogalvanic Currents in Steel Reinforced Concrete
[Display omitted] •Temperature gradients generate galvanic currents, due to changes in cement chemistry and passive layer.•30°C is the critical temperature for switching polarity of galvanic couples between steel rebars.•In NaOH solution carbon steel behaves cathodically with respect to stainless st...
Saved in:
Published in: | Electrochimica acta 2016-06, Vol.202, p.269-276 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | [Display omitted]
•Temperature gradients generate galvanic currents, due to changes in cement chemistry and passive layer.•30°C is the critical temperature for switching polarity of galvanic couples between steel rebars.•In NaOH solution carbon steel behaves cathodically with respect to stainless steel for T |
---|---|