Loading…

Influence of Working Pressure on Ion Sensitive Probe Measurement in Microwave ECR Plasmas

In order to precisely measure the ion parameters in a microwave electron cyclotron resonance plasma using an ion sensitive probe,the dependences of the current-voltage(I-V)characteristics on the shielding height(h)and the potential difference between inner and outer electrodes(V_B)have been investig...

Full description

Saved in:
Bibliographic Details
Published in:Plasma science & technology 2015-04, Vol.17 (4), p.294-297
Main Author: 马志斌 吴俊 谭必松 沈武林 潘鑫 汪建华
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:In order to precisely measure the ion parameters in a microwave electron cyclotron resonance plasma using an ion sensitive probe,the dependences of the current-voltage(I-V)characteristics on the shielding height(h)and the potential difference between inner and outer electrodes(V_B)have been investigated at different working pressures of 0.03 Pa and 0.8 Pa.Results show that the I-V curves at higher pressure are more sensitive to the variation of h than those at lower pressure.The influence of V_B on ion temperature(T_i)measurement becomes more prominent when the pressure is increased from 0.03 Pa to 0.8 Pa.Under both pressures,the optimized h is obtained at the condition where the current reaches zero in the positive voltage region with a suitable V_B of-1.5 V because of effective shielding of the electron E×B drift.
ISSN:1009-0630
DOI:10.1088/1009-0630/17/4/06