Loading…
Wavelength-meter controlled cavity ring-down spectroscopy: high-sensitivity detection of trace moisture in N sub(2) at sub-ppb levels
We present a relatively simple technique to efficiently couple a laser to a high-finesse cavity in cavity ring-down spectroscopy (CRDS). The frequency of the probe laser is coupled to a resonant frequency of the cavity using a high-resolution wavelength meter. The repetition rate of measurement of t...
Saved in:
Published in: | Sensors and actuators. A. Physical. 2016-04, Vol.241, p.152-160 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | 160 |
container_issue | |
container_start_page | 152 |
container_title | Sensors and actuators. A. Physical. |
container_volume | 241 |
creator | Hashiguchi, Koji Lisak, Daniel Cygan, Agata Ciurylo, Roman Ciurylo Abe, Hisashi |
description | We present a relatively simple technique to efficiently couple a laser to a high-finesse cavity in cavity ring-down spectroscopy (CRDS). The frequency of the probe laser is coupled to a resonant frequency of the cavity using a high-resolution wavelength meter. The repetition rate of measurement of the ring-down events obtained is 150 Hz. We attain a noise equivalent absorption coefficient of 5.2 10 super(-11) cm super(-1) Hz super(-1/2) and a minimum detectable absorption coefficient of 6.7 10 super(-12) cm super(-1) (after 70 s averaging). We find significant deviations in the indications (readings) of the wavelength meter, probably because of dispersion due to residual moisture inside the interferometer. The dew point of the residual moisture is estimated to be -13.9 degree C. By correcting the deviations on the basis of experimentally obtained data, a near-infrared (1393 nm) spectrum of H sub(2)O is efficiently recorded in the range of 7179.537 cm super(-1)-7183.330 cm super(-1) (containing 539 spectral points) in 15 min. Analysis of the average of the eight spectra acquired in 2 h shows a baseline noise (one standard deviation) of 1.3 10 super(-11) cm super(-1), corresponding to 0.012 nmol/mol (0.012 ppb) of H sub(2)O in N sub(2) in amount-of-substance fraction (mole fraction). |
doi_str_mv | 10.1016/j.sna.2016.02.016 |
format | article |
fullrecord | <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_miscellaneous_1825483129</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1825483129</sourcerecordid><originalsourceid>FETCH-proquest_miscellaneous_18254831293</originalsourceid><addsrcrecordid>eNqVjT1OAzEUhF2ARPg5AN0rQ2Fjexc2oUUgKiokysjxvuw68trGzxuUA3BvDOICVPNJ82mGsWslhZLq_nYvKBihKwqpRY0TtpBr3fJWt90ZOyfaSymbpusW7OvdHNBjGMrIJyyYwcZQcvQee7Dm4MoRsgsD7-NnAEpoa0k2puMDjG4YOWEgV9yv2NcBW1wMEHdQsrEIU3RU5ozgArwCzdulvgFTfointAWP9Z4u2enOeMKrv7xgy-ent8cXnnL8mJHKZnJk0XsTMM60USt9164apdfNP9RvqT1cZw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1825483129</pqid></control><display><type>article</type><title>Wavelength-meter controlled cavity ring-down spectroscopy: high-sensitivity detection of trace moisture in N sub(2) at sub-ppb levels</title><source>ScienceDirect Freedom Collection 2022-2024</source><creator>Hashiguchi, Koji ; Lisak, Daniel ; Cygan, Agata ; Ciurylo, Roman Ciurylo ; Abe, Hisashi</creator><creatorcontrib>Hashiguchi, Koji ; Lisak, Daniel ; Cygan, Agata ; Ciurylo, Roman Ciurylo ; Abe, Hisashi</creatorcontrib><description>We present a relatively simple technique to efficiently couple a laser to a high-finesse cavity in cavity ring-down spectroscopy (CRDS). The frequency of the probe laser is coupled to a resonant frequency of the cavity using a high-resolution wavelength meter. The repetition rate of measurement of the ring-down events obtained is 150 Hz. We attain a noise equivalent absorption coefficient of 5.2 10 super(-11) cm super(-1) Hz super(-1/2) and a minimum detectable absorption coefficient of 6.7 10 super(-12) cm super(-1) (after 70 s averaging). We find significant deviations in the indications (readings) of the wavelength meter, probably because of dispersion due to residual moisture inside the interferometer. The dew point of the residual moisture is estimated to be -13.9 degree C. By correcting the deviations on the basis of experimentally obtained data, a near-infrared (1393 nm) spectrum of H sub(2)O is efficiently recorded in the range of 7179.537 cm super(-1)-7183.330 cm super(-1) (containing 539 spectral points) in 15 min. Analysis of the average of the eight spectra acquired in 2 h shows a baseline noise (one standard deviation) of 1.3 10 super(-11) cm super(-1), corresponding to 0.012 nmol/mol (0.012 ppb) of H sub(2)O in N sub(2) in amount-of-substance fraction (mole fraction).</description><identifier>ISSN: 0924-4247</identifier><identifier>DOI: 10.1016/j.sna.2016.02.016</identifier><language>eng</language><subject>Deviation ; Holes ; Lasers ; Measuring instruments ; Meters ; Moisture ; Spectra ; Wavelengths</subject><ispartof>Sensors and actuators. A. Physical., 2016-04, Vol.241, p.152-160</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,778,782,27911,27912</link.rule.ids></links><search><creatorcontrib>Hashiguchi, Koji</creatorcontrib><creatorcontrib>Lisak, Daniel</creatorcontrib><creatorcontrib>Cygan, Agata</creatorcontrib><creatorcontrib>Ciurylo, Roman Ciurylo</creatorcontrib><creatorcontrib>Abe, Hisashi</creatorcontrib><title>Wavelength-meter controlled cavity ring-down spectroscopy: high-sensitivity detection of trace moisture in N sub(2) at sub-ppb levels</title><title>Sensors and actuators. A. Physical.</title><description>We present a relatively simple technique to efficiently couple a laser to a high-finesse cavity in cavity ring-down spectroscopy (CRDS). The frequency of the probe laser is coupled to a resonant frequency of the cavity using a high-resolution wavelength meter. The repetition rate of measurement of the ring-down events obtained is 150 Hz. We attain a noise equivalent absorption coefficient of 5.2 10 super(-11) cm super(-1) Hz super(-1/2) and a minimum detectable absorption coefficient of 6.7 10 super(-12) cm super(-1) (after 70 s averaging). We find significant deviations in the indications (readings) of the wavelength meter, probably because of dispersion due to residual moisture inside the interferometer. The dew point of the residual moisture is estimated to be -13.9 degree C. By correcting the deviations on the basis of experimentally obtained data, a near-infrared (1393 nm) spectrum of H sub(2)O is efficiently recorded in the range of 7179.537 cm super(-1)-7183.330 cm super(-1) (containing 539 spectral points) in 15 min. Analysis of the average of the eight spectra acquired in 2 h shows a baseline noise (one standard deviation) of 1.3 10 super(-11) cm super(-1), corresponding to 0.012 nmol/mol (0.012 ppb) of H sub(2)O in N sub(2) in amount-of-substance fraction (mole fraction).</description><subject>Deviation</subject><subject>Holes</subject><subject>Lasers</subject><subject>Measuring instruments</subject><subject>Meters</subject><subject>Moisture</subject><subject>Spectra</subject><subject>Wavelengths</subject><issn>0924-4247</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><recordid>eNqVjT1OAzEUhF2ARPg5AN0rQ2Fjexc2oUUgKiokysjxvuw68trGzxuUA3BvDOICVPNJ82mGsWslhZLq_nYvKBihKwqpRY0TtpBr3fJWt90ZOyfaSymbpusW7OvdHNBjGMrIJyyYwcZQcvQee7Dm4MoRsgsD7-NnAEpoa0k2puMDjG4YOWEgV9yv2NcBW1wMEHdQsrEIU3RU5ozgArwCzdulvgFTfointAWP9Z4u2enOeMKrv7xgy-ent8cXnnL8mJHKZnJk0XsTMM60USt9164apdfNP9RvqT1cZw</recordid><startdate>20160415</startdate><enddate>20160415</enddate><creator>Hashiguchi, Koji</creator><creator>Lisak, Daniel</creator><creator>Cygan, Agata</creator><creator>Ciurylo, Roman Ciurylo</creator><creator>Abe, Hisashi</creator><scope>7TB</scope><scope>7U5</scope><scope>8FD</scope><scope>FR3</scope><scope>L7M</scope></search><sort><creationdate>20160415</creationdate><title>Wavelength-meter controlled cavity ring-down spectroscopy: high-sensitivity detection of trace moisture in N sub(2) at sub-ppb levels</title><author>Hashiguchi, Koji ; Lisak, Daniel ; Cygan, Agata ; Ciurylo, Roman Ciurylo ; Abe, Hisashi</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_miscellaneous_18254831293</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Deviation</topic><topic>Holes</topic><topic>Lasers</topic><topic>Measuring instruments</topic><topic>Meters</topic><topic>Moisture</topic><topic>Spectra</topic><topic>Wavelengths</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hashiguchi, Koji</creatorcontrib><creatorcontrib>Lisak, Daniel</creatorcontrib><creatorcontrib>Cygan, Agata</creatorcontrib><creatorcontrib>Ciurylo, Roman Ciurylo</creatorcontrib><creatorcontrib>Abe, Hisashi</creatorcontrib><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Sensors and actuators. A. Physical.</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hashiguchi, Koji</au><au>Lisak, Daniel</au><au>Cygan, Agata</au><au>Ciurylo, Roman Ciurylo</au><au>Abe, Hisashi</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Wavelength-meter controlled cavity ring-down spectroscopy: high-sensitivity detection of trace moisture in N sub(2) at sub-ppb levels</atitle><jtitle>Sensors and actuators. A. Physical.</jtitle><date>2016-04-15</date><risdate>2016</risdate><volume>241</volume><spage>152</spage><epage>160</epage><pages>152-160</pages><issn>0924-4247</issn><abstract>We present a relatively simple technique to efficiently couple a laser to a high-finesse cavity in cavity ring-down spectroscopy (CRDS). The frequency of the probe laser is coupled to a resonant frequency of the cavity using a high-resolution wavelength meter. The repetition rate of measurement of the ring-down events obtained is 150 Hz. We attain a noise equivalent absorption coefficient of 5.2 10 super(-11) cm super(-1) Hz super(-1/2) and a minimum detectable absorption coefficient of 6.7 10 super(-12) cm super(-1) (after 70 s averaging). We find significant deviations in the indications (readings) of the wavelength meter, probably because of dispersion due to residual moisture inside the interferometer. The dew point of the residual moisture is estimated to be -13.9 degree C. By correcting the deviations on the basis of experimentally obtained data, a near-infrared (1393 nm) spectrum of H sub(2)O is efficiently recorded in the range of 7179.537 cm super(-1)-7183.330 cm super(-1) (containing 539 spectral points) in 15 min. Analysis of the average of the eight spectra acquired in 2 h shows a baseline noise (one standard deviation) of 1.3 10 super(-11) cm super(-1), corresponding to 0.012 nmol/mol (0.012 ppb) of H sub(2)O in N sub(2) in amount-of-substance fraction (mole fraction).</abstract><doi>10.1016/j.sna.2016.02.016</doi></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0924-4247 |
ispartof | Sensors and actuators. A. Physical., 2016-04, Vol.241, p.152-160 |
issn | 0924-4247 |
language | eng |
recordid | cdi_proquest_miscellaneous_1825483129 |
source | ScienceDirect Freedom Collection 2022-2024 |
subjects | Deviation Holes Lasers Measuring instruments Meters Moisture Spectra Wavelengths |
title | Wavelength-meter controlled cavity ring-down spectroscopy: high-sensitivity detection of trace moisture in N sub(2) at sub-ppb levels |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-15T09%3A38%3A24IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Wavelength-meter%20controlled%20cavity%20ring-down%20spectroscopy:%20high-sensitivity%20detection%20of%20trace%20moisture%20in%20N%20sub(2)%20at%20sub-ppb%20levels&rft.jtitle=Sensors%20and%20actuators.%20A.%20Physical.&rft.au=Hashiguchi,%20Koji&rft.date=2016-04-15&rft.volume=241&rft.spage=152&rft.epage=160&rft.pages=152-160&rft.issn=0924-4247&rft_id=info:doi/10.1016/j.sna.2016.02.016&rft_dat=%3Cproquest%3E1825483129%3C/proquest%3E%3Cgrp_id%3Ecdi_FETCH-proquest_miscellaneous_18254831293%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1825483129&rft_id=info:pmid/&rfr_iscdi=true |