Loading…
Real‐time simulator for designing electron dual scattering foil systems
The purpose of this work was to develop a user friendly, accurate, real‐time computer simulator to facilitate the design of dual foil scattering systems for electron beams on radiotherapy accelerators. The simulator allows for a relatively quick, initial design that can be refined and verified with...
Saved in:
Published in: | Journal of applied clinical medical physics 2014-11, Vol.15 (6), p.323-342 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The purpose of this work was to develop a user friendly, accurate, real‐time computer simulator to facilitate the design of dual foil scattering systems for electron beams on radiotherapy accelerators. The simulator allows for a relatively quick, initial design that can be refined and verified with subsequent Monte Carlo (MC) calculations and measurements. The simulator also is a powerful educational tool. The simulator consists of an analytical algorithm for calculating electron fluence and X‐ray dose and a graphical user interface (GUI) C++ program. The algorithm predicts electron fluence using Fermi‐Eyges multiple Coulomb scattering theory with the reduced Gaussian formalism for scattering powers. The simulator also estimates central‐axis and off‐axis X‐ray dose arising from the dual foil system. Once the geometry of the accelerator is specified, the simulator allows the user to continuously vary primary scattering foil material and thickness, secondary scattering foil material and Gaussian shape (thickness and sigma), and beam energy. The off‐axis electron relative fluence or total dose profile and central‐axis X‐ray dose contamination are computed and displayed in real time. The simulator was validated by comparison of off‐axis electron relative fluence and X‐ray percent dose profiles with those calculated using EGSnrc MC. Over the energy range 7–20 MeV, using present foils on an Elekta radiotherapy accelerator, the simulator was able to reproduce MC profiles to within 2% out to 20 cm from the central axis. The central‐axis X‐ray percent dose predictions matched measured data to within 0.5%. The calculation time was approximately 100 ms using a single Intel 2.93 GHz processor, which allows for real‐time variation of foil geometrical parameters using slider bars. This work demonstrates how the user‐friendly GUI and real‐time nature of the simulator make it an effective educational tool for gaining a better understanding of the effects that various system parameters have on a relative dose profile. This work also demonstrates a method for using the simulator as a design tool for creating custom dual scattering foil systems in the clinical range of beam energies (6–20 MeV).
PACS number: 87.10.Ca |
---|---|
ISSN: | 1526-9914 1526-9914 |
DOI: | 10.1120/jacmp.v15i6.4849 |