Mechanical behavior of zirconia and titanium abutments before and after cyclic load application
Abstract Statement of problem Esthetic factors influence the decision to use titanium or zirconia abutments in anterior regions. Clinicians may have concerns about the durability and behavior of these zirconia abutments. Purpose The purpose of this in vitro study was to evaluate the longitudinal and...
Saved in:
Published in: | The Journal of prosthetic dentistry 2016-10, Vol.116 (4), p.529-535 |
---|---|
Main Authors: | , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c537t-4bc48147734b4c647d245fcd73e7e94494bf4cbba132d89be81ae072e89119843 |
---|---|
cites | cdi_FETCH-LOGICAL-c537t-4bc48147734b4c647d245fcd73e7e94494bf4cbba132d89be81ae072e89119843 |
container_end_page | 535 |
container_issue | 4 |
container_start_page | 529 |
container_title | The Journal of prosthetic dentistry |
container_volume | 116 |
creator | Gehrke, Sergio Alexandre, DDS, PhD Poncio da Silva, Pablo Mateus, MS Calvo Guirado, José Luiz, DDS, PhD Delgado-Ruiz, Rafael Arcesio, DDS, PhD Dedavid, Berenice Anina, PhD Aline Nagasawa, Magda, DDS Shibli, Jamil Awad, DDS, PhD |
description | Abstract Statement of problem Esthetic factors influence the decision to use titanium or zirconia abutments in anterior regions. Clinicians may have concerns about the durability and behavior of these zirconia abutments. Purpose The purpose of this in vitro study was to evaluate the longitudinal and transverse long axes of the implant-abutment interface before and after the cyclic loading of titanium and zirconia abutments with an external hexagon. Material and methods Forty dental implants with an external hexagon and 40 corresponding abutments made of titanium (Ti) and zirconia (Zr) were subjected to cyclic load (c1) versus no load (c2). The longitudinal and transverse axes of 4 experimental groups (Tic1, Tic2, Zrc1, and Zrc2) were analyzed (vertical/horizontal adjustment) using a scanning electron microscope at ×1000 magnification. The differences among the groups were determined by 1-way analysis of variance (ANOVA) and post hoc Tukey tests (α=.05). T tests were used to identify the statistically significant differences between each group and each condition (α=.05). Results Significant differences were found among the groups with respect to the misfits analyzed in the 2 sections (longitudinal and transverse) before and after load application ( P |
doi_str_mv | 10.1016/j.prosdent.2016.02.015 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1826675688</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>1_s2_0_S0022391316001578</els_id><sourcerecordid>1826675688</sourcerecordid><originalsourceid>FETCH-LOGICAL-c537t-4bc48147734b4c647d245fcd73e7e94494bf4cbba132d89be81ae072e89119843</originalsourceid><addsrcrecordid>eNqFkUtv1DAUhS0EotPCX6iyZJPU13FsZ4NAVXlIrVi0rC3buVE9JPFgO5WGX4-n07Jg05Vf59wjf4eQc6ANUBAX22YXQxpwyQ0r54ayhkL3imyA9rIWisNrsqGUsbrtoT0hpyltKaWqk_CWnDAJnRRUbYi-QXdvFu_MVFm8Nw8-xCqM1R8fXVi8qcwyVNnnIlnnytg1zyUzFe0YIj6-mjFjrNzeTd5VUzDlZrcre5N9WN6RN6OZEr5_Ws_Izy9Xd5ff6usfX79ffr6uXdfKXHPruAIuZcstd4LLgfFudINsUWLPec_tyJ21Blo2qN6iAoNUMlQ9QK94e0Y-HOcWLL9XTFnPPjmcJrNgWJMGxYSQnVCqSMVR6grBFHHUu-hnE_caqD7A1Vv9DFcf4GrKdIFbjOdPGaudcfhne6ZZBJ-OAiw_ffAYdXIeF4eDj-iyHoJ_OePjfyMK1sd6fuEe0zascSkcNehUDPr2UPGhYRC02KVq_wIb5qQ8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1826675688</pqid></control><display><type>article</type><title>Mechanical behavior of zirconia and titanium abutments before and after cyclic load application</title><source>ScienceDirect Journals</source><creator>Gehrke, Sergio Alexandre, DDS, PhD ; Poncio da Silva, Pablo Mateus, MS ; Calvo Guirado, José Luiz, DDS, PhD ; Delgado-Ruiz, Rafael Arcesio, DDS, PhD ; Dedavid, Berenice Anina, PhD ; Aline Nagasawa, Magda, DDS ; Shibli, Jamil Awad, DDS, PhD</creator><creatorcontrib>Gehrke, Sergio Alexandre, DDS, PhD ; Poncio da Silva, Pablo Mateus, MS ; Calvo Guirado, José Luiz, DDS, PhD ; Delgado-Ruiz, Rafael Arcesio, DDS, PhD ; Dedavid, Berenice Anina, PhD ; Aline Nagasawa, Magda, DDS ; Shibli, Jamil Awad, DDS, PhD</creatorcontrib><description>Abstract Statement of problem Esthetic factors influence the decision to use titanium or zirconia abutments in anterior regions. Clinicians may have concerns about the durability and behavior of these zirconia abutments. Purpose The purpose of this in vitro study was to evaluate the longitudinal and transverse long axes of the implant-abutment interface before and after the cyclic loading of titanium and zirconia abutments with an external hexagon. Material and methods Forty dental implants with an external hexagon and 40 corresponding abutments made of titanium (Ti) and zirconia (Zr) were subjected to cyclic load (c1) versus no load (c2). The longitudinal and transverse axes of 4 experimental groups (Tic1, Tic2, Zrc1, and Zrc2) were analyzed (vertical/horizontal adjustment) using a scanning electron microscope at ×1000 magnification. The differences among the groups were determined by 1-way analysis of variance (ANOVA) and post hoc Tukey tests (α=.05). T tests were used to identify the statistically significant differences between each group and each condition (α=.05). Results Significant differences were found among the groups with respect to the misfits analyzed in the 2 sections (longitudinal and transverse) before and after load application ( P <.05). The behaviors of the groups differed particularly with regard to the accommodation of sets (abutment/implant) after the application of cyclic loads ( P <.05). Conclusion The use of zirconia abutments in titanium implants can cause changes to and/or permanent deformation of the implant hexagon.</description><identifier>ISSN: 0022-3913</identifier><identifier>EISSN: 1097-6841</identifier><identifier>DOI: 10.1016/j.prosdent.2016.02.015</identifier><identifier>PMID: 27157608</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Dental Abutments ; Dental Implant-Abutment Design ; Dental Stress Analysis ; Dentistry ; Hardness ; Humans ; In Vitro Techniques ; Microscopy, Electron, Scanning ; Titanium ; Zirconium</subject><ispartof>The Journal of prosthetic dentistry, 2016-10, Vol.116 (4), p.529-535</ispartof><rights>Editorial Council for the Journal of Prosthetic Dentistry</rights><rights>2016 Editorial Council for the Journal of Prosthetic Dentistry</rights><rights>Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c537t-4bc48147734b4c647d245fcd73e7e94494bf4cbba132d89be81ae072e89119843</citedby><cites>FETCH-LOGICAL-c537t-4bc48147734b4c647d245fcd73e7e94494bf4cbba132d89be81ae072e89119843</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/27157608$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Gehrke, Sergio Alexandre, DDS, PhD</creatorcontrib><creatorcontrib>Poncio da Silva, Pablo Mateus, MS</creatorcontrib><creatorcontrib>Calvo Guirado, José Luiz, DDS, PhD</creatorcontrib><creatorcontrib>Delgado-Ruiz, Rafael Arcesio, DDS, PhD</creatorcontrib><creatorcontrib>Dedavid, Berenice Anina, PhD</creatorcontrib><creatorcontrib>Aline Nagasawa, Magda, DDS</creatorcontrib><creatorcontrib>Shibli, Jamil Awad, DDS, PhD</creatorcontrib><title>Mechanical behavior of zirconia and titanium abutments before and after cyclic load application</title><title>The Journal of prosthetic dentistry</title><addtitle>J Prosthet Dent</addtitle><description>Abstract Statement of problem Esthetic factors influence the decision to use titanium or zirconia abutments in anterior regions. Clinicians may have concerns about the durability and behavior of these zirconia abutments. Purpose The purpose of this in vitro study was to evaluate the longitudinal and transverse long axes of the implant-abutment interface before and after the cyclic loading of titanium and zirconia abutments with an external hexagon. Material and methods Forty dental implants with an external hexagon and 40 corresponding abutments made of titanium (Ti) and zirconia (Zr) were subjected to cyclic load (c1) versus no load (c2). The longitudinal and transverse axes of 4 experimental groups (Tic1, Tic2, Zrc1, and Zrc2) were analyzed (vertical/horizontal adjustment) using a scanning electron microscope at ×1000 magnification. The differences among the groups were determined by 1-way analysis of variance (ANOVA) and post hoc Tukey tests (α=.05). T tests were used to identify the statistically significant differences between each group and each condition (α=.05). Results Significant differences were found among the groups with respect to the misfits analyzed in the 2 sections (longitudinal and transverse) before and after load application ( P <.05). The behaviors of the groups differed particularly with regard to the accommodation of sets (abutment/implant) after the application of cyclic loads ( P <.05). Conclusion The use of zirconia abutments in titanium implants can cause changes to and/or permanent deformation of the implant hexagon.</description><subject>Dental Abutments</subject><subject>Dental Implant-Abutment Design</subject><subject>Dental Stress Analysis</subject><subject>Dentistry</subject><subject>Hardness</subject><subject>Humans</subject><subject>In Vitro Techniques</subject><subject>Microscopy, Electron, Scanning</subject><subject>Titanium</subject><subject>Zirconium</subject><issn>0022-3913</issn><issn>1097-6841</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><recordid>eNqFkUtv1DAUhS0EotPCX6iyZJPU13FsZ4NAVXlIrVi0rC3buVE9JPFgO5WGX4-n07Jg05Vf59wjf4eQc6ANUBAX22YXQxpwyQ0r54ayhkL3imyA9rIWisNrsqGUsbrtoT0hpyltKaWqk_CWnDAJnRRUbYi-QXdvFu_MVFm8Nw8-xCqM1R8fXVi8qcwyVNnnIlnnytg1zyUzFe0YIj6-mjFjrNzeTd5VUzDlZrcre5N9WN6RN6OZEr5_Ws_Izy9Xd5ff6usfX79ffr6uXdfKXHPruAIuZcstd4LLgfFudINsUWLPec_tyJ21Blo2qN6iAoNUMlQ9QK94e0Y-HOcWLL9XTFnPPjmcJrNgWJMGxYSQnVCqSMVR6grBFHHUu-hnE_caqD7A1Vv9DFcf4GrKdIFbjOdPGaudcfhne6ZZBJ-OAiw_ffAYdXIeF4eDj-iyHoJ_OePjfyMK1sd6fuEe0zascSkcNehUDPr2UPGhYRC02KVq_wIb5qQ8</recordid><startdate>20161001</startdate><enddate>20161001</enddate><creator>Gehrke, Sergio Alexandre, DDS, PhD</creator><creator>Poncio da Silva, Pablo Mateus, MS</creator><creator>Calvo Guirado, José Luiz, DDS, PhD</creator><creator>Delgado-Ruiz, Rafael Arcesio, DDS, PhD</creator><creator>Dedavid, Berenice Anina, PhD</creator><creator>Aline Nagasawa, Magda, DDS</creator><creator>Shibli, Jamil Awad, DDS, PhD</creator><general>Elsevier Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20161001</creationdate><title>Mechanical behavior of zirconia and titanium abutments before and after cyclic load application</title><author>Gehrke, Sergio Alexandre, DDS, PhD ; Poncio da Silva, Pablo Mateus, MS ; Calvo Guirado, José Luiz, DDS, PhD ; Delgado-Ruiz, Rafael Arcesio, DDS, PhD ; Dedavid, Berenice Anina, PhD ; Aline Nagasawa, Magda, DDS ; Shibli, Jamil Awad, DDS, PhD</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c537t-4bc48147734b4c647d245fcd73e7e94494bf4cbba132d89be81ae072e89119843</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Dental Abutments</topic><topic>Dental Implant-Abutment Design</topic><topic>Dental Stress Analysis</topic><topic>Dentistry</topic><topic>Hardness</topic><topic>Humans</topic><topic>In Vitro Techniques</topic><topic>Microscopy, Electron, Scanning</topic><topic>Titanium</topic><topic>Zirconium</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Gehrke, Sergio Alexandre, DDS, PhD</creatorcontrib><creatorcontrib>Poncio da Silva, Pablo Mateus, MS</creatorcontrib><creatorcontrib>Calvo Guirado, José Luiz, DDS, PhD</creatorcontrib><creatorcontrib>Delgado-Ruiz, Rafael Arcesio, DDS, PhD</creatorcontrib><creatorcontrib>Dedavid, Berenice Anina, PhD</creatorcontrib><creatorcontrib>Aline Nagasawa, Magda, DDS</creatorcontrib><creatorcontrib>Shibli, Jamil Awad, DDS, PhD</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The Journal of prosthetic dentistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gehrke, Sergio Alexandre, DDS, PhD</au><au>Poncio da Silva, Pablo Mateus, MS</au><au>Calvo Guirado, José Luiz, DDS, PhD</au><au>Delgado-Ruiz, Rafael Arcesio, DDS, PhD</au><au>Dedavid, Berenice Anina, PhD</au><au>Aline Nagasawa, Magda, DDS</au><au>Shibli, Jamil Awad, DDS, PhD</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Mechanical behavior of zirconia and titanium abutments before and after cyclic load application</atitle><jtitle>The Journal of prosthetic dentistry</jtitle><addtitle>J Prosthet Dent</addtitle><date>2016-10-01</date><risdate>2016</risdate><volume>116</volume><issue>4</issue><spage>529</spage><epage>535</epage><pages>529-535</pages><issn>0022-3913</issn><eissn>1097-6841</eissn><abstract>Abstract Statement of problem Esthetic factors influence the decision to use titanium or zirconia abutments in anterior regions. Clinicians may have concerns about the durability and behavior of these zirconia abutments. Purpose The purpose of this in vitro study was to evaluate the longitudinal and transverse long axes of the implant-abutment interface before and after the cyclic loading of titanium and zirconia abutments with an external hexagon. Material and methods Forty dental implants with an external hexagon and 40 corresponding abutments made of titanium (Ti) and zirconia (Zr) were subjected to cyclic load (c1) versus no load (c2). The longitudinal and transverse axes of 4 experimental groups (Tic1, Tic2, Zrc1, and Zrc2) were analyzed (vertical/horizontal adjustment) using a scanning electron microscope at ×1000 magnification. The differences among the groups were determined by 1-way analysis of variance (ANOVA) and post hoc Tukey tests (α=.05). T tests were used to identify the statistically significant differences between each group and each condition (α=.05). Results Significant differences were found among the groups with respect to the misfits analyzed in the 2 sections (longitudinal and transverse) before and after load application ( P <.05). The behaviors of the groups differed particularly with regard to the accommodation of sets (abutment/implant) after the application of cyclic loads ( P <.05). Conclusion The use of zirconia abutments in titanium implants can cause changes to and/or permanent deformation of the implant hexagon.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>27157608</pmid><doi>10.1016/j.prosdent.2016.02.015</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0022-3913 |
ispartof | The Journal of prosthetic dentistry, 2016-10, Vol.116 (4), p.529-535 |
issn | 0022-3913 1097-6841 |
language | eng |
recordid | cdi_proquest_miscellaneous_1826675688 |
source | ScienceDirect Journals |
subjects | Dental Abutments Dental Implant-Abutment Design Dental Stress Analysis Dentistry Hardness Humans In Vitro Techniques Microscopy, Electron, Scanning Titanium Zirconium |
title | Mechanical behavior of zirconia and titanium abutments before and after cyclic load application |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T04%3A51%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Mechanical%20behavior%20of%20zirconia%20and%20titanium%20abutments%20before%20and%20after%20cyclic%20load%20application&rft.jtitle=The%20Journal%20of%20prosthetic%20dentistry&rft.au=Gehrke,%20Sergio%20Alexandre,%20DDS,%20PhD&rft.date=2016-10-01&rft.volume=116&rft.issue=4&rft.spage=529&rft.epage=535&rft.pages=529-535&rft.issn=0022-3913&rft.eissn=1097-6841&rft_id=info:doi/10.1016/j.prosdent.2016.02.015&rft_dat=%3Cproquest_cross%3E1826675688%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c537t-4bc48147734b4c647d245fcd73e7e94494bf4cbba132d89be81ae072e89119843%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1826675688&rft_id=info:pmid/27157608&rfr_iscdi=true |