Loading…
A SINGLE-EXPOSURE, MULTIDETECTOR NEUTRON SPECTROMETER FOR WORKPLACE MONITORING
This communication describes a recently developed single-exposure neutron spectrometer, based on multiple active thermal neutron detectors located within a moderating sphere, which have been developed jointly by CIEMAT (Spain), INFN (Italy) and Politecnico di Milano (Italy) in the framework of Itali...
Saved in:
Published in: | Radiation protection dosimetry 2016-09, Vol.170 (1-4), p.326-330 |
---|---|
Main Authors: | , , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c320t-67820eee29d735b9e78fe61c87326642fc3f63eae82422a2183f292e6cf8811a3 |
---|---|
cites | cdi_FETCH-LOGICAL-c320t-67820eee29d735b9e78fe61c87326642fc3f63eae82422a2183f292e6cf8811a3 |
container_end_page | 330 |
container_issue | 1-4 |
container_start_page | 326 |
container_title | Radiation protection dosimetry |
container_volume | 170 |
creator | Bedogni, R Bortot, D Buonomo, B Esposito, A Gómez-Ros, J M Introini, M V Mazzitelli, G Moraleda, M Pola, A Romero, A M |
description | This communication describes a recently developed single-exposure neutron spectrometer, based on multiple active thermal neutron detectors located within a moderating sphere, which have been developed jointly by CIEMAT (Spain), INFN (Italy) and Politecnico di Milano (Italy) in the framework of Italian and Spanish collaboration projects. The fabricated prototypes permit to achieve spectrometric resolution with nearly isotropic response for neutron with energies from thermal to 100-200 MeV, thus being able to characterise the complete neutron spectrum in only one exposure by unfolding the measured responses of the detectors. This makes it especially advantageous for characterising neutron fields and workplace monitoring purposes in neutron-producing facilities. |
doi_str_mv | 10.1093/rpd/ncv380 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1827926633</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1827926633</sourcerecordid><originalsourceid>FETCH-LOGICAL-c320t-67820eee29d735b9e78fe61c87326642fc3f63eae82422a2183f292e6cf8811a3</originalsourceid><addsrcrecordid>eNqNkF1LwzAUQIMobk5f_AHSRxHrkpssSR9HzWaxa0fXom-lyxKY7MtmE_z3RqY--xRu7uHAPQhdE_xAcET77W7R3-gPKvEJ6hLBIKQM81PUxYSxUDLAHXTh3BvGIKIBO0cd4CC4xLKLsmEwS7JxqkL1Os1nVaHug0mVlsmjKlVc5kWQqaos8iyYTf1c5BP_XwQjv3jJi-dpOoxVMMmzxKPec4nObLNy5urn7aFqpMr4KUzzcRIP01BTwPuQCwnYGAPRQtDBPDJCWsOJloIC5wysppZT0xgJDKABIqmFCAzXVkpCGtpDt0fvrt2-H4zb1-ul02a1ajZme3A1kf5Ur6L0H6i300HEpUfvjqhut861xta7drlu2s-a4Po7de1T18fUHr758R7ma7P4Q3_b0i9fZnKa</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1818335968</pqid></control><display><type>article</type><title>A SINGLE-EXPOSURE, MULTIDETECTOR NEUTRON SPECTROMETER FOR WORKPLACE MONITORING</title><source>Oxford University Press:Jisc Collections:OUP Read and Publish 2024-2025 (2024 collection) (Reading list)</source><creator>Bedogni, R ; Bortot, D ; Buonomo, B ; Esposito, A ; Gómez-Ros, J M ; Introini, M V ; Mazzitelli, G ; Moraleda, M ; Pola, A ; Romero, A M</creator><creatorcontrib>Bedogni, R ; Bortot, D ; Buonomo, B ; Esposito, A ; Gómez-Ros, J M ; Introini, M V ; Mazzitelli, G ; Moraleda, M ; Pola, A ; Romero, A M</creatorcontrib><description>This communication describes a recently developed single-exposure neutron spectrometer, based on multiple active thermal neutron detectors located within a moderating sphere, which have been developed jointly by CIEMAT (Spain), INFN (Italy) and Politecnico di Milano (Italy) in the framework of Italian and Spanish collaboration projects. The fabricated prototypes permit to achieve spectrometric resolution with nearly isotropic response for neutron with energies from thermal to 100-200 MeV, thus being able to characterise the complete neutron spectrum in only one exposure by unfolding the measured responses of the detectors. This makes it especially advantageous for characterising neutron fields and workplace monitoring purposes in neutron-producing facilities.</description><identifier>ISSN: 0144-8420</identifier><identifier>EISSN: 1742-3406</identifier><identifier>DOI: 10.1093/rpd/ncv380</identifier><identifier>PMID: 26276808</identifier><language>eng</language><publisher>England</publisher><subject>Calibration ; Humans ; Italy ; Neutrons ; Occupational Exposure - analysis ; Occupational Exposure - prevention & control ; Photons ; Polyethylene ; Radiation Dosage ; Radiation Dosimeters ; Radiation Monitoring - instrumentation ; Radiation Monitoring - methods ; Radiation Protection - instrumentation ; Radiation Protection - methods ; Reproducibility of Results ; Spain ; Spectrum Analysis - instrumentation ; Workplace</subject><ispartof>Radiation protection dosimetry, 2016-09, Vol.170 (1-4), p.326-330</ispartof><rights>The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c320t-67820eee29d735b9e78fe61c87326642fc3f63eae82422a2183f292e6cf8811a3</citedby><cites>FETCH-LOGICAL-c320t-67820eee29d735b9e78fe61c87326642fc3f63eae82422a2183f292e6cf8811a3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/26276808$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Bedogni, R</creatorcontrib><creatorcontrib>Bortot, D</creatorcontrib><creatorcontrib>Buonomo, B</creatorcontrib><creatorcontrib>Esposito, A</creatorcontrib><creatorcontrib>Gómez-Ros, J M</creatorcontrib><creatorcontrib>Introini, M V</creatorcontrib><creatorcontrib>Mazzitelli, G</creatorcontrib><creatorcontrib>Moraleda, M</creatorcontrib><creatorcontrib>Pola, A</creatorcontrib><creatorcontrib>Romero, A M</creatorcontrib><title>A SINGLE-EXPOSURE, MULTIDETECTOR NEUTRON SPECTROMETER FOR WORKPLACE MONITORING</title><title>Radiation protection dosimetry</title><addtitle>Radiat Prot Dosimetry</addtitle><description>This communication describes a recently developed single-exposure neutron spectrometer, based on multiple active thermal neutron detectors located within a moderating sphere, which have been developed jointly by CIEMAT (Spain), INFN (Italy) and Politecnico di Milano (Italy) in the framework of Italian and Spanish collaboration projects. The fabricated prototypes permit to achieve spectrometric resolution with nearly isotropic response for neutron with energies from thermal to 100-200 MeV, thus being able to characterise the complete neutron spectrum in only one exposure by unfolding the measured responses of the detectors. This makes it especially advantageous for characterising neutron fields and workplace monitoring purposes in neutron-producing facilities.</description><subject>Calibration</subject><subject>Humans</subject><subject>Italy</subject><subject>Neutrons</subject><subject>Occupational Exposure - analysis</subject><subject>Occupational Exposure - prevention & control</subject><subject>Photons</subject><subject>Polyethylene</subject><subject>Radiation Dosage</subject><subject>Radiation Dosimeters</subject><subject>Radiation Monitoring - instrumentation</subject><subject>Radiation Monitoring - methods</subject><subject>Radiation Protection - instrumentation</subject><subject>Radiation Protection - methods</subject><subject>Reproducibility of Results</subject><subject>Spain</subject><subject>Spectrum Analysis - instrumentation</subject><subject>Workplace</subject><issn>0144-8420</issn><issn>1742-3406</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><recordid>eNqNkF1LwzAUQIMobk5f_AHSRxHrkpssSR9HzWaxa0fXom-lyxKY7MtmE_z3RqY--xRu7uHAPQhdE_xAcET77W7R3-gPKvEJ6hLBIKQM81PUxYSxUDLAHXTh3BvGIKIBO0cd4CC4xLKLsmEwS7JxqkL1Os1nVaHug0mVlsmjKlVc5kWQqaos8iyYTf1c5BP_XwQjv3jJi-dpOoxVMMmzxKPec4nObLNy5urn7aFqpMr4KUzzcRIP01BTwPuQCwnYGAPRQtDBPDJCWsOJloIC5wysppZT0xgJDKABIqmFCAzXVkpCGtpDt0fvrt2-H4zb1-ul02a1ajZme3A1kf5Ur6L0H6i300HEpUfvjqhut861xta7drlu2s-a4Po7de1T18fUHr758R7ma7P4Q3_b0i9fZnKa</recordid><startdate>201609</startdate><enddate>201609</enddate><creator>Bedogni, R</creator><creator>Bortot, D</creator><creator>Buonomo, B</creator><creator>Esposito, A</creator><creator>Gómez-Ros, J M</creator><creator>Introini, M V</creator><creator>Mazzitelli, G</creator><creator>Moraleda, M</creator><creator>Pola, A</creator><creator>Romero, A M</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>7ST</scope><scope>7U7</scope><scope>C1K</scope><scope>SOI</scope></search><sort><creationdate>201609</creationdate><title>A SINGLE-EXPOSURE, MULTIDETECTOR NEUTRON SPECTROMETER FOR WORKPLACE MONITORING</title><author>Bedogni, R ; Bortot, D ; Buonomo, B ; Esposito, A ; Gómez-Ros, J M ; Introini, M V ; Mazzitelli, G ; Moraleda, M ; Pola, A ; Romero, A M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c320t-67820eee29d735b9e78fe61c87326642fc3f63eae82422a2183f292e6cf8811a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Calibration</topic><topic>Humans</topic><topic>Italy</topic><topic>Neutrons</topic><topic>Occupational Exposure - analysis</topic><topic>Occupational Exposure - prevention & control</topic><topic>Photons</topic><topic>Polyethylene</topic><topic>Radiation Dosage</topic><topic>Radiation Dosimeters</topic><topic>Radiation Monitoring - instrumentation</topic><topic>Radiation Monitoring - methods</topic><topic>Radiation Protection - instrumentation</topic><topic>Radiation Protection - methods</topic><topic>Reproducibility of Results</topic><topic>Spain</topic><topic>Spectrum Analysis - instrumentation</topic><topic>Workplace</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bedogni, R</creatorcontrib><creatorcontrib>Bortot, D</creatorcontrib><creatorcontrib>Buonomo, B</creatorcontrib><creatorcontrib>Esposito, A</creatorcontrib><creatorcontrib>Gómez-Ros, J M</creatorcontrib><creatorcontrib>Introini, M V</creatorcontrib><creatorcontrib>Mazzitelli, G</creatorcontrib><creatorcontrib>Moraleda, M</creatorcontrib><creatorcontrib>Pola, A</creatorcontrib><creatorcontrib>Romero, A M</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>Environment Abstracts</collection><collection>Toxicology Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Environment Abstracts</collection><jtitle>Radiation protection dosimetry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bedogni, R</au><au>Bortot, D</au><au>Buonomo, B</au><au>Esposito, A</au><au>Gómez-Ros, J M</au><au>Introini, M V</au><au>Mazzitelli, G</au><au>Moraleda, M</au><au>Pola, A</au><au>Romero, A M</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A SINGLE-EXPOSURE, MULTIDETECTOR NEUTRON SPECTROMETER FOR WORKPLACE MONITORING</atitle><jtitle>Radiation protection dosimetry</jtitle><addtitle>Radiat Prot Dosimetry</addtitle><date>2016-09</date><risdate>2016</risdate><volume>170</volume><issue>1-4</issue><spage>326</spage><epage>330</epage><pages>326-330</pages><issn>0144-8420</issn><eissn>1742-3406</eissn><abstract>This communication describes a recently developed single-exposure neutron spectrometer, based on multiple active thermal neutron detectors located within a moderating sphere, which have been developed jointly by CIEMAT (Spain), INFN (Italy) and Politecnico di Milano (Italy) in the framework of Italian and Spanish collaboration projects. The fabricated prototypes permit to achieve spectrometric resolution with nearly isotropic response for neutron with energies from thermal to 100-200 MeV, thus being able to characterise the complete neutron spectrum in only one exposure by unfolding the measured responses of the detectors. This makes it especially advantageous for characterising neutron fields and workplace monitoring purposes in neutron-producing facilities.</abstract><cop>England</cop><pmid>26276808</pmid><doi>10.1093/rpd/ncv380</doi><tpages>5</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0144-8420 |
ispartof | Radiation protection dosimetry, 2016-09, Vol.170 (1-4), p.326-330 |
issn | 0144-8420 1742-3406 |
language | eng |
recordid | cdi_proquest_miscellaneous_1827926633 |
source | Oxford University Press:Jisc Collections:OUP Read and Publish 2024-2025 (2024 collection) (Reading list) |
subjects | Calibration Humans Italy Neutrons Occupational Exposure - analysis Occupational Exposure - prevention & control Photons Polyethylene Radiation Dosage Radiation Dosimeters Radiation Monitoring - instrumentation Radiation Monitoring - methods Radiation Protection - instrumentation Radiation Protection - methods Reproducibility of Results Spain Spectrum Analysis - instrumentation Workplace |
title | A SINGLE-EXPOSURE, MULTIDETECTOR NEUTRON SPECTROMETER FOR WORKPLACE MONITORING |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-23T06%3A04%3A26IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20SINGLE-EXPOSURE,%20MULTIDETECTOR%20NEUTRON%20SPECTROMETER%20FOR%20WORKPLACE%20MONITORING&rft.jtitle=Radiation%20protection%20dosimetry&rft.au=Bedogni,%20R&rft.date=2016-09&rft.volume=170&rft.issue=1-4&rft.spage=326&rft.epage=330&rft.pages=326-330&rft.issn=0144-8420&rft.eissn=1742-3406&rft_id=info:doi/10.1093/rpd/ncv380&rft_dat=%3Cproquest_cross%3E1827926633%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c320t-67820eee29d735b9e78fe61c87326642fc3f63eae82422a2183f292e6cf8811a3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1818335968&rft_id=info:pmid/26276808&rfr_iscdi=true |