Loading…
Effectiveness-NTU analyses in a double tube heat exchanger equipped with wavy strip considering various angles
•Double tube heat exchanger equipped with wavy strip turbulators was studied.•The effects of wavy strip angles on the effectiveness were investigated.•Variation of the effectiveness with hot and cold water flow rate was presented.•The effectiveness increases with the decrease of wavy strip angle.•Th...
Saved in:
Published in: | Energy conversion and management 2016-09, Vol.123, p.462-469 |
---|---|
Main Authors: | , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c378t-bfe7904508817d9d3db4d9689b1dd6d5fe7b75f7085e6df1c0aa84c47eca1aaa3 |
---|---|
cites | cdi_FETCH-LOGICAL-c378t-bfe7904508817d9d3db4d9689b1dd6d5fe7b75f7085e6df1c0aa84c47eca1aaa3 |
container_end_page | 469 |
container_issue | |
container_start_page | 462 |
container_title | Energy conversion and management |
container_volume | 123 |
creator | Pourahmad, Saman Pesteei, S.M. |
description | •Double tube heat exchanger equipped with wavy strip turbulators was studied.•The effects of wavy strip angles on the effectiveness were investigated.•Variation of the effectiveness with hot and cold water flow rate was presented.•The effectiveness increases with the decrease of wavy strip angle.•The friction factor increases with the decrease of wavy strip angle.
In the present study, effectiveness-NTU analyses in a double tube heat exchanger equipped with wavy strip considering various angles were experimentally studied. Moreover, variation of the effectiveness with hot water Reynolds numbers for different cold water flow rates were presented. These turbulators with different angles of 45°, 60°, 90°, 120° and 150° were made of galvanized plates with thickness of 1mm and were installed in the inner tube of heat exchanger. The experiments were carried out at Reynolds numbers of 3000–13,500 at turbulent flow regime. Throughout the experiments, hot and cold water flowed through the inner pipe and the space between the pipes (annulus), respectively. It was tried to keep the inlet hot and cold water temperatures at constant values. Effectiveness-NTU analyses were made for the conditions with and without wavy strips including their different angles and compared to each other. Results showed the considerable effect of turbulators on effectiveness (ε) and number of heat transfer units (NTU) of double tube heat exchanger. In addition, some empirical correlations expressing the results were also developed based on curve fitting. |
doi_str_mv | 10.1016/j.enconman.2016.06.063 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1835558954</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0196890416305520</els_id><sourcerecordid>1835558954</sourcerecordid><originalsourceid>FETCH-LOGICAL-c378t-bfe7904508817d9d3db4d9689b1dd6d5fe7b75f7085e6df1c0aa84c47eca1aaa3</originalsourceid><addsrcrecordid>eNqNUctOwzAQtBBIlMcvIB-5pNhNnDg3UFUeUgUXerY29qZ1lTqpnbT073FVOIO00mq1M6PZHULuOBtzxvOH9Ridbt0G3HgS5zE7VnpGRlwWZTKZTIpzMmK8zBNZsuySXIWwZoylguUj4mZ1jbq3O3QYQvL-uaDgoDkEDNQ6CtS0Q9Ug7YcK6Qqhp_ilV-CW6CluB9t1aOje9iu6h92Bht7bjkY3wRr01i3pDrxthxBVlw2GG3JRQxPw9qdfk8Xz7HP6msw_Xt6mT_NEp4Xsk6rGInoVTEpemNKkpspMmcuy4sbkRsR1VYi6YFJgbmquGYDMdFagBg4A6TW5P-l2vt0OGHq1sUFj04DD6EZxmQohZCmyf0A5lzJnXERofoJq34bgsVadtxvwB8WZOmah1uo3C3XMQrFjpZH4eCJivHln0augbUSisT5-X5nW_iXxDYZQmJk</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1811886015</pqid></control><display><type>article</type><title>Effectiveness-NTU analyses in a double tube heat exchanger equipped with wavy strip considering various angles</title><source>ScienceDirect Journals</source><creator>Pourahmad, Saman ; Pesteei, S.M.</creator><creatorcontrib>Pourahmad, Saman ; Pesteei, S.M.</creatorcontrib><description>•Double tube heat exchanger equipped with wavy strip turbulators was studied.•The effects of wavy strip angles on the effectiveness were investigated.•Variation of the effectiveness with hot and cold water flow rate was presented.•The effectiveness increases with the decrease of wavy strip angle.•The friction factor increases with the decrease of wavy strip angle.
In the present study, effectiveness-NTU analyses in a double tube heat exchanger equipped with wavy strip considering various angles were experimentally studied. Moreover, variation of the effectiveness with hot water Reynolds numbers for different cold water flow rates were presented. These turbulators with different angles of 45°, 60°, 90°, 120° and 150° were made of galvanized plates with thickness of 1mm and were installed in the inner tube of heat exchanger. The experiments were carried out at Reynolds numbers of 3000–13,500 at turbulent flow regime. Throughout the experiments, hot and cold water flowed through the inner pipe and the space between the pipes (annulus), respectively. It was tried to keep the inlet hot and cold water temperatures at constant values. Effectiveness-NTU analyses were made for the conditions with and without wavy strips including their different angles and compared to each other. Results showed the considerable effect of turbulators on effectiveness (ε) and number of heat transfer units (NTU) of double tube heat exchanger. In addition, some empirical correlations expressing the results were also developed based on curve fitting.</description><identifier>ISSN: 0196-8904</identifier><identifier>EISSN: 1879-2227</identifier><identifier>DOI: 10.1016/j.enconman.2016.06.063</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>Cold water ; Double tube heat exchanger ; Effectiveness ; Fluid dynamics ; Fluid flow ; NTU ; Reynolds number ; Strip ; Tube heat exchangers ; Turbulator ; Turbulence ; Turbulent flow ; Wavy strips</subject><ispartof>Energy conversion and management, 2016-09, Vol.123, p.462-469</ispartof><rights>2016 Elsevier Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c378t-bfe7904508817d9d3db4d9689b1dd6d5fe7b75f7085e6df1c0aa84c47eca1aaa3</citedby><cites>FETCH-LOGICAL-c378t-bfe7904508817d9d3db4d9689b1dd6d5fe7b75f7085e6df1c0aa84c47eca1aaa3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Pourahmad, Saman</creatorcontrib><creatorcontrib>Pesteei, S.M.</creatorcontrib><title>Effectiveness-NTU analyses in a double tube heat exchanger equipped with wavy strip considering various angles</title><title>Energy conversion and management</title><description>•Double tube heat exchanger equipped with wavy strip turbulators was studied.•The effects of wavy strip angles on the effectiveness were investigated.•Variation of the effectiveness with hot and cold water flow rate was presented.•The effectiveness increases with the decrease of wavy strip angle.•The friction factor increases with the decrease of wavy strip angle.
In the present study, effectiveness-NTU analyses in a double tube heat exchanger equipped with wavy strip considering various angles were experimentally studied. Moreover, variation of the effectiveness with hot water Reynolds numbers for different cold water flow rates were presented. These turbulators with different angles of 45°, 60°, 90°, 120° and 150° were made of galvanized plates with thickness of 1mm and were installed in the inner tube of heat exchanger. The experiments were carried out at Reynolds numbers of 3000–13,500 at turbulent flow regime. Throughout the experiments, hot and cold water flowed through the inner pipe and the space between the pipes (annulus), respectively. It was tried to keep the inlet hot and cold water temperatures at constant values. Effectiveness-NTU analyses were made for the conditions with and without wavy strips including their different angles and compared to each other. Results showed the considerable effect of turbulators on effectiveness (ε) and number of heat transfer units (NTU) of double tube heat exchanger. In addition, some empirical correlations expressing the results were also developed based on curve fitting.</description><subject>Cold water</subject><subject>Double tube heat exchanger</subject><subject>Effectiveness</subject><subject>Fluid dynamics</subject><subject>Fluid flow</subject><subject>NTU</subject><subject>Reynolds number</subject><subject>Strip</subject><subject>Tube heat exchangers</subject><subject>Turbulator</subject><subject>Turbulence</subject><subject>Turbulent flow</subject><subject>Wavy strips</subject><issn>0196-8904</issn><issn>1879-2227</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><recordid>eNqNUctOwzAQtBBIlMcvIB-5pNhNnDg3UFUeUgUXerY29qZ1lTqpnbT073FVOIO00mq1M6PZHULuOBtzxvOH9Ridbt0G3HgS5zE7VnpGRlwWZTKZTIpzMmK8zBNZsuySXIWwZoylguUj4mZ1jbq3O3QYQvL-uaDgoDkEDNQ6CtS0Q9Ug7YcK6Qqhp_ilV-CW6CluB9t1aOje9iu6h92Bht7bjkY3wRr01i3pDrxthxBVlw2GG3JRQxPw9qdfk8Xz7HP6msw_Xt6mT_NEp4Xsk6rGInoVTEpemNKkpspMmcuy4sbkRsR1VYi6YFJgbmquGYDMdFagBg4A6TW5P-l2vt0OGHq1sUFj04DD6EZxmQohZCmyf0A5lzJnXERofoJq34bgsVadtxvwB8WZOmah1uo3C3XMQrFjpZH4eCJivHln0augbUSisT5-X5nW_iXxDYZQmJk</recordid><startdate>20160901</startdate><enddate>20160901</enddate><creator>Pourahmad, Saman</creator><creator>Pesteei, S.M.</creator><general>Elsevier Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7ST</scope><scope>C1K</scope><scope>SOI</scope><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope><scope>H8D</scope><scope>KR7</scope><scope>L7M</scope></search><sort><creationdate>20160901</creationdate><title>Effectiveness-NTU analyses in a double tube heat exchanger equipped with wavy strip considering various angles</title><author>Pourahmad, Saman ; Pesteei, S.M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c378t-bfe7904508817d9d3db4d9689b1dd6d5fe7b75f7085e6df1c0aa84c47eca1aaa3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Cold water</topic><topic>Double tube heat exchanger</topic><topic>Effectiveness</topic><topic>Fluid dynamics</topic><topic>Fluid flow</topic><topic>NTU</topic><topic>Reynolds number</topic><topic>Strip</topic><topic>Tube heat exchangers</topic><topic>Turbulator</topic><topic>Turbulence</topic><topic>Turbulent flow</topic><topic>Wavy strips</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Pourahmad, Saman</creatorcontrib><creatorcontrib>Pesteei, S.M.</creatorcontrib><collection>CrossRef</collection><collection>Environment Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Environment Abstracts</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Energy conversion and management</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Pourahmad, Saman</au><au>Pesteei, S.M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Effectiveness-NTU analyses in a double tube heat exchanger equipped with wavy strip considering various angles</atitle><jtitle>Energy conversion and management</jtitle><date>2016-09-01</date><risdate>2016</risdate><volume>123</volume><spage>462</spage><epage>469</epage><pages>462-469</pages><issn>0196-8904</issn><eissn>1879-2227</eissn><abstract>•Double tube heat exchanger equipped with wavy strip turbulators was studied.•The effects of wavy strip angles on the effectiveness were investigated.•Variation of the effectiveness with hot and cold water flow rate was presented.•The effectiveness increases with the decrease of wavy strip angle.•The friction factor increases with the decrease of wavy strip angle.
In the present study, effectiveness-NTU analyses in a double tube heat exchanger equipped with wavy strip considering various angles were experimentally studied. Moreover, variation of the effectiveness with hot water Reynolds numbers for different cold water flow rates were presented. These turbulators with different angles of 45°, 60°, 90°, 120° and 150° were made of galvanized plates with thickness of 1mm and were installed in the inner tube of heat exchanger. The experiments were carried out at Reynolds numbers of 3000–13,500 at turbulent flow regime. Throughout the experiments, hot and cold water flowed through the inner pipe and the space between the pipes (annulus), respectively. It was tried to keep the inlet hot and cold water temperatures at constant values. Effectiveness-NTU analyses were made for the conditions with and without wavy strips including their different angles and compared to each other. Results showed the considerable effect of turbulators on effectiveness (ε) and number of heat transfer units (NTU) of double tube heat exchanger. In addition, some empirical correlations expressing the results were also developed based on curve fitting.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.enconman.2016.06.063</doi><tpages>8</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0196-8904 |
ispartof | Energy conversion and management, 2016-09, Vol.123, p.462-469 |
issn | 0196-8904 1879-2227 |
language | eng |
recordid | cdi_proquest_miscellaneous_1835558954 |
source | ScienceDirect Journals |
subjects | Cold water Double tube heat exchanger Effectiveness Fluid dynamics Fluid flow NTU Reynolds number Strip Tube heat exchangers Turbulator Turbulence Turbulent flow Wavy strips |
title | Effectiveness-NTU analyses in a double tube heat exchanger equipped with wavy strip considering various angles |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T03%3A55%3A26IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Effectiveness-NTU%20analyses%20in%20a%20double%20tube%20heat%20exchanger%20equipped%20with%20wavy%20strip%20considering%20various%20angles&rft.jtitle=Energy%20conversion%20and%20management&rft.au=Pourahmad,%20Saman&rft.date=2016-09-01&rft.volume=123&rft.spage=462&rft.epage=469&rft.pages=462-469&rft.issn=0196-8904&rft.eissn=1879-2227&rft_id=info:doi/10.1016/j.enconman.2016.06.063&rft_dat=%3Cproquest_cross%3E1835558954%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c378t-bfe7904508817d9d3db4d9689b1dd6d5fe7b75f7085e6df1c0aa84c47eca1aaa3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1811886015&rft_id=info:pmid/&rfr_iscdi=true |