Simultaneous multi-element and isotope ratio imaging of fish otoliths by laser ablation split stream ICP-MS/MC ICP-MS

The simultaneous retrieval of spatially resolved information on the elemental content and isotope ratios from the same sampling spot ( e.g. in incrementally grown biological material) still represents an analytical challenge. In order to assess multi-elemental (Sr/Ca; Mg/Ca; Ba/Ca; Na/Ca) and isotop...

Full description

Saved in:
Bibliographic Details
Published in:Journal of analytical atomic spectrometry 2016-01, Vol.31 (8), p.1612-1621
Main Authors: Prohaska, T, Irrgeher, J, Zitek, A
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c322t-fecd40c908c6ba594e7ed1c112cc8e8f6608abc5278e0a22c0415717e88795ce3
cites cdi_FETCH-LOGICAL-c322t-fecd40c908c6ba594e7ed1c112cc8e8f6608abc5278e0a22c0415717e88795ce3
container_end_page 1621
container_issue 8
container_start_page 1612
container_title Journal of analytical atomic spectrometry
container_volume 31
creator Prohaska, T
Irrgeher, J
Zitek, A
description The simultaneous retrieval of spatially resolved information on the elemental content and isotope ratios from the same sampling spot ( e.g. in incrementally grown biological material) still represents an analytical challenge. In order to assess multi-elemental (Sr/Ca; Mg/Ca; Ba/Ca; Na/Ca) and isotopic ( 87 Sr/ 86 Sr) data simultaneously on a fish otolith surface, a laser ablation (LA) system was coupled simultaneously to a multicollector inductively coupled plasma mass spectrometer (MC ICP-MS) and a quadrupole (single collector) ICP-MS via an aerosol split. In addition, a membrane desolvation nebulizer was used for introducing liquid standards in-line to the MC ICP-MS system. The recorded time resolved data of different data density (number of data points/time unit were by a factor of 4 higher using MC ICP-MS) were spatially referenced to the picture using ArcGIS® software. This allowed for the creation of elemental and isotopic images and the combination of data of different spatial resolution. Finally, regions of similar chemical composition were retrieved by cluster analysis. The method was applied to analyze an otolith of a lenok ( Brachymystax lenok ) caught in the river Eg (northern Mongolia) to assess habitat use and migration in a river system, where only little is known about the migrations of native fish. The combined statistical evaluations of the data showed that the Sr/Ca elemental and 87 Sr/ 86 Sr isotope ratios assessed in the otolith were the main discriminators of three clearly different zones on the otolith, indicating habitat shifts. Split-stream LA-ICP-MS/MC ICP-MS proved to be a compelling approach to gain elemental and isotopic data simultaneously from the same sampling spots on solid samples with a minimum loss of information. The simultaneous retrieval of spatially resolved information on the elemental content and isotope ratios from the same sampling spot ( e.g. in incrementally grown biological material) still represents an analytical challenge.
doi_str_mv 10.1039/c6ja00087h
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1835561448</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1835561448</sourcerecordid><originalsourceid>FETCH-LOGICAL-c322t-fecd40c908c6ba594e7ed1c112cc8e8f6608abc5278e0a22c0415717e88795ce3</originalsourceid><addsrcrecordid>eNpFkM9LwzAYhoMoOKcX70KOItQlbdKkx1HUTTYUpueSZl-3jPSHSXrYf29nRU_fC-_DB--D0C0lj5Qk2UynB0UIkWJ_hiY0SVnEOWPnaELiVEQZE-ISXXl_GBjGYz5B_cbUvQ2qgbb3-BRNBBZqaAJWzRYb34a2A-xUMC02tdqZZofbClfG7_HQWRP2HpdHbJUHh1VpT2SDfTc02AcHqsbL_D1ab2br_Dddo4tKWQ83v3eKPp-fPvJFtHp7WebzVaSTOA5RBXrLiM6I1GmpeMZAwJZqSmOtJcgqTYlUpeaxkEBUHGvCKBdUgJQi4xqSKbof_3au_erBh6I2XoO1496CyoTzlDImB_RhRLVrvXdQFZ0b5rpjQUlxclvk6ev8x-1igO9G2Hn9x_27T74BZup2hA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1835561448</pqid></control><display><type>article</type><title>Simultaneous multi-element and isotope ratio imaging of fish otoliths by laser ablation split stream ICP-MS/MC ICP-MS</title><source>Royal Society of Chemistry:Jisc Collections:Royal Society of Chemistry Read and Publish 2022-2024 (reading list)</source><creator>Prohaska, T ; Irrgeher, J ; Zitek, A</creator><creatorcontrib>Prohaska, T ; Irrgeher, J ; Zitek, A</creatorcontrib><description>The simultaneous retrieval of spatially resolved information on the elemental content and isotope ratios from the same sampling spot ( e.g. in incrementally grown biological material) still represents an analytical challenge. In order to assess multi-elemental (Sr/Ca; Mg/Ca; Ba/Ca; Na/Ca) and isotopic ( 87 Sr/ 86 Sr) data simultaneously on a fish otolith surface, a laser ablation (LA) system was coupled simultaneously to a multicollector inductively coupled plasma mass spectrometer (MC ICP-MS) and a quadrupole (single collector) ICP-MS via an aerosol split. In addition, a membrane desolvation nebulizer was used for introducing liquid standards in-line to the MC ICP-MS system. The recorded time resolved data of different data density (number of data points/time unit were by a factor of 4 higher using MC ICP-MS) were spatially referenced to the picture using ArcGIS® software. This allowed for the creation of elemental and isotopic images and the combination of data of different spatial resolution. Finally, regions of similar chemical composition were retrieved by cluster analysis. The method was applied to analyze an otolith of a lenok ( Brachymystax lenok ) caught in the river Eg (northern Mongolia) to assess habitat use and migration in a river system, where only little is known about the migrations of native fish. The combined statistical evaluations of the data showed that the Sr/Ca elemental and 87 Sr/ 86 Sr isotope ratios assessed in the otolith were the main discriminators of three clearly different zones on the otolith, indicating habitat shifts. Split-stream LA-ICP-MS/MC ICP-MS proved to be a compelling approach to gain elemental and isotopic data simultaneously from the same sampling spots on solid samples with a minimum loss of information. The simultaneous retrieval of spatially resolved information on the elemental content and isotope ratios from the same sampling spot ( e.g. in incrementally grown biological material) still represents an analytical challenge.</description><identifier>ISSN: 0267-9477</identifier><identifier>EISSN: 1364-5544</identifier><identifier>DOI: 10.1039/c6ja00087h</identifier><language>eng</language><subject>Fish ; Habitats ; Isotope ratios ; Laser ablation ; Migration ; Rivers ; Sampling ; Spots</subject><ispartof>Journal of analytical atomic spectrometry, 2016-01, Vol.31 (8), p.1612-1621</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c322t-fecd40c908c6ba594e7ed1c112cc8e8f6608abc5278e0a22c0415717e88795ce3</citedby><cites>FETCH-LOGICAL-c322t-fecd40c908c6ba594e7ed1c112cc8e8f6608abc5278e0a22c0415717e88795ce3</cites><orcidid>0000-0003-3192-0101</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Prohaska, T</creatorcontrib><creatorcontrib>Irrgeher, J</creatorcontrib><creatorcontrib>Zitek, A</creatorcontrib><title>Simultaneous multi-element and isotope ratio imaging of fish otoliths by laser ablation split stream ICP-MS/MC ICP-MS</title><title>Journal of analytical atomic spectrometry</title><description>The simultaneous retrieval of spatially resolved information on the elemental content and isotope ratios from the same sampling spot ( e.g. in incrementally grown biological material) still represents an analytical challenge. In order to assess multi-elemental (Sr/Ca; Mg/Ca; Ba/Ca; Na/Ca) and isotopic ( 87 Sr/ 86 Sr) data simultaneously on a fish otolith surface, a laser ablation (LA) system was coupled simultaneously to a multicollector inductively coupled plasma mass spectrometer (MC ICP-MS) and a quadrupole (single collector) ICP-MS via an aerosol split. In addition, a membrane desolvation nebulizer was used for introducing liquid standards in-line to the MC ICP-MS system. The recorded time resolved data of different data density (number of data points/time unit were by a factor of 4 higher using MC ICP-MS) were spatially referenced to the picture using ArcGIS® software. This allowed for the creation of elemental and isotopic images and the combination of data of different spatial resolution. Finally, regions of similar chemical composition were retrieved by cluster analysis. The method was applied to analyze an otolith of a lenok ( Brachymystax lenok ) caught in the river Eg (northern Mongolia) to assess habitat use and migration in a river system, where only little is known about the migrations of native fish. The combined statistical evaluations of the data showed that the Sr/Ca elemental and 87 Sr/ 86 Sr isotope ratios assessed in the otolith were the main discriminators of three clearly different zones on the otolith, indicating habitat shifts. Split-stream LA-ICP-MS/MC ICP-MS proved to be a compelling approach to gain elemental and isotopic data simultaneously from the same sampling spots on solid samples with a minimum loss of information. The simultaneous retrieval of spatially resolved information on the elemental content and isotope ratios from the same sampling spot ( e.g. in incrementally grown biological material) still represents an analytical challenge.</description><subject>Fish</subject><subject>Habitats</subject><subject>Isotope ratios</subject><subject>Laser ablation</subject><subject>Migration</subject><subject>Rivers</subject><subject>Sampling</subject><subject>Spots</subject><issn>0267-9477</issn><issn>1364-5544</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><recordid>eNpFkM9LwzAYhoMoOKcX70KOItQlbdKkx1HUTTYUpueSZl-3jPSHSXrYf29nRU_fC-_DB--D0C0lj5Qk2UynB0UIkWJ_hiY0SVnEOWPnaELiVEQZE-ISXXl_GBjGYz5B_cbUvQ2qgbb3-BRNBBZqaAJWzRYb34a2A-xUMC02tdqZZofbClfG7_HQWRP2HpdHbJUHh1VpT2SDfTc02AcHqsbL_D1ab2br_Dddo4tKWQ83v3eKPp-fPvJFtHp7WebzVaSTOA5RBXrLiM6I1GmpeMZAwJZqSmOtJcgqTYlUpeaxkEBUHGvCKBdUgJQi4xqSKbof_3au_erBh6I2XoO1496CyoTzlDImB_RhRLVrvXdQFZ0b5rpjQUlxclvk6ev8x-1igO9G2Hn9x_27T74BZup2hA</recordid><startdate>20160101</startdate><enddate>20160101</enddate><creator>Prohaska, T</creator><creator>Irrgeher, J</creator><creator>Zitek, A</creator><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope><scope>L7M</scope><orcidid>https://orcid.org/0000-0003-3192-0101</orcidid></search><sort><creationdate>20160101</creationdate><title>Simultaneous multi-element and isotope ratio imaging of fish otoliths by laser ablation split stream ICP-MS/MC ICP-MS</title><author>Prohaska, T ; Irrgeher, J ; Zitek, A</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c322t-fecd40c908c6ba594e7ed1c112cc8e8f6608abc5278e0a22c0415717e88795ce3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Fish</topic><topic>Habitats</topic><topic>Isotope ratios</topic><topic>Laser ablation</topic><topic>Migration</topic><topic>Rivers</topic><topic>Sampling</topic><topic>Spots</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Prohaska, T</creatorcontrib><creatorcontrib>Irrgeher, J</creatorcontrib><creatorcontrib>Zitek, A</creatorcontrib><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Journal of analytical atomic spectrometry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Prohaska, T</au><au>Irrgeher, J</au><au>Zitek, A</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Simultaneous multi-element and isotope ratio imaging of fish otoliths by laser ablation split stream ICP-MS/MC ICP-MS</atitle><jtitle>Journal of analytical atomic spectrometry</jtitle><date>2016-01-01</date><risdate>2016</risdate><volume>31</volume><issue>8</issue><spage>1612</spage><epage>1621</epage><pages>1612-1621</pages><issn>0267-9477</issn><eissn>1364-5544</eissn><abstract>The simultaneous retrieval of spatially resolved information on the elemental content and isotope ratios from the same sampling spot ( e.g. in incrementally grown biological material) still represents an analytical challenge. In order to assess multi-elemental (Sr/Ca; Mg/Ca; Ba/Ca; Na/Ca) and isotopic ( 87 Sr/ 86 Sr) data simultaneously on a fish otolith surface, a laser ablation (LA) system was coupled simultaneously to a multicollector inductively coupled plasma mass spectrometer (MC ICP-MS) and a quadrupole (single collector) ICP-MS via an aerosol split. In addition, a membrane desolvation nebulizer was used for introducing liquid standards in-line to the MC ICP-MS system. The recorded time resolved data of different data density (number of data points/time unit were by a factor of 4 higher using MC ICP-MS) were spatially referenced to the picture using ArcGIS® software. This allowed for the creation of elemental and isotopic images and the combination of data of different spatial resolution. Finally, regions of similar chemical composition were retrieved by cluster analysis. The method was applied to analyze an otolith of a lenok ( Brachymystax lenok ) caught in the river Eg (northern Mongolia) to assess habitat use and migration in a river system, where only little is known about the migrations of native fish. The combined statistical evaluations of the data showed that the Sr/Ca elemental and 87 Sr/ 86 Sr isotope ratios assessed in the otolith were the main discriminators of three clearly different zones on the otolith, indicating habitat shifts. Split-stream LA-ICP-MS/MC ICP-MS proved to be a compelling approach to gain elemental and isotopic data simultaneously from the same sampling spots on solid samples with a minimum loss of information. The simultaneous retrieval of spatially resolved information on the elemental content and isotope ratios from the same sampling spot ( e.g. in incrementally grown biological material) still represents an analytical challenge.</abstract><doi>10.1039/c6ja00087h</doi><tpages>1</tpages><orcidid>https://orcid.org/0000-0003-3192-0101</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0267-9477
ispartof Journal of analytical atomic spectrometry, 2016-01, Vol.31 (8), p.1612-1621
issn 0267-9477
1364-5544
language eng
recordid cdi_proquest_miscellaneous_1835561448
source Royal Society of Chemistry:Jisc Collections:Royal Society of Chemistry Read and Publish 2022-2024 (reading list)
subjects Fish
Habitats
Isotope ratios
Laser ablation
Migration
Rivers
Sampling
Spots
title Simultaneous multi-element and isotope ratio imaging of fish otoliths by laser ablation split stream ICP-MS/MC ICP-MS
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T19%3A48%3A52IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Simultaneous%20multi-element%20and%20isotope%20ratio%20imaging%20of%20fish%20otoliths%20by%20laser%20ablation%20split%20stream%20ICP-MS/MC%20ICP-MS&rft.jtitle=Journal%20of%20analytical%20atomic%20spectrometry&rft.au=Prohaska,%20T&rft.date=2016-01-01&rft.volume=31&rft.issue=8&rft.spage=1612&rft.epage=1621&rft.pages=1612-1621&rft.issn=0267-9477&rft.eissn=1364-5544&rft_id=info:doi/10.1039/c6ja00087h&rft_dat=%3Cproquest_cross%3E1835561448%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c322t-fecd40c908c6ba594e7ed1c112cc8e8f6608abc5278e0a22c0415717e88795ce3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1835561448&rft_id=info:pmid/&rfr_iscdi=true