Fracture of Hex Bars During Manufacture
A manufacturer of hex bars experienced occasional post heat treatment cracking. Metallography, SEM fractography, and microhardness testing demonstrated that quench cracking was the cause of failure. The manufacturer had the heat treatment modified in order to eliminate the cause of failure.
Saved in:
Published in: | Journal of failure analysis and prevention 2016-08, Vol.16 (4), p.533-536 |
---|---|
Main Authors: | , |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | A manufacturer of hex bars experienced occasional post heat treatment cracking. Metallography, SEM fractography, and microhardness testing demonstrated that quench cracking was the cause of failure. The manufacturer had the heat treatment modified in order to eliminate the cause of failure. |
---|---|