Microdevice with integrated multi-enzyme sensors for the measurement of pork freshness

An electrochemical microdevice for measuring pork freshness was developed based on the value of measurement indicators—K, Ki, and H. Four sensors were integrated to measure the sum of the concentrations appearing in the equations that define the K, Ki, and H values. With standard solutions, the corr...

Full description

Saved in:
Bibliographic Details
Published in:Sensors and actuators. B, Chemical Chemical, 2016-11, Vol.235, p.535-540
Main Authors: Qiu, Xiaoli, Itoh, Daisuke, Satake, Takaaki, Suzuki, Hiroaki
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c330t-e06924b0d0a749d9afd1589c49eea16fc81b4092a8acc52c4d528a66e2c8ceff3
cites cdi_FETCH-LOGICAL-c330t-e06924b0d0a749d9afd1589c49eea16fc81b4092a8acc52c4d528a66e2c8ceff3
container_end_page 540
container_issue
container_start_page 535
container_title Sensors and actuators. B, Chemical
container_volume 235
creator Qiu, Xiaoli
Itoh, Daisuke
Satake, Takaaki
Suzuki, Hiroaki
description An electrochemical microdevice for measuring pork freshness was developed based on the value of measurement indicators—K, Ki, and H. Four sensors were integrated to measure the sum of the concentrations appearing in the equations that define the K, Ki, and H values. With standard solutions, the correlation coefficients for sensors 1–4 were 0.888, 0.979, 0.816, and 0.828, respectively. Each sensor could complete one measurement in 2min. A good correlation was obtained between the K values measured by the proposed microdevice and by ultra-performance liquid chromatography. Based on the sensor responses obtained with real pork extract samples, the R2 value between the K and Ki values was 0.843, while that between the K and H values was only 0.807 during a 15-day storage period.
doi_str_mv 10.1016/j.snb.2016.05.074
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1835629507</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0925400516307572</els_id><sourcerecordid>1835629507</sourcerecordid><originalsourceid>FETCH-LOGICAL-c330t-e06924b0d0a749d9afd1589c49eea16fc81b4092a8acc52c4d528a66e2c8ceff3</originalsourceid><addsrcrecordid>eNp9kD1PwzAQhi0EEqXwA9g8siSckzgfYkIVX1IRC7BarnOmLk1cfE5R-fWkKjPT3fA-p3sfxi4FpAJEeb1KqV-k2bimIFOoiiM2EXWVJzlU1TGbQJPJpACQp-yMaAUARV7ChL0_OxN8i1tnkH-7uOSuj_gRdMSWd8M6ugT7n12HnLAnH4hbH3hcIu9Q0xCwwz5yb_nGh09uA9KyR6JzdmL1mvDib07Z2_3d6-wxmb88PM1u54nJc4gJQtlkxQJa0FXRtI22rZB1Y4oGUYvSmlosivF1XWtjZGaKVma1LkvMTG3Q2nzKrg53N8F_DUhRdY4Mrte6Rz-QEnUuy6yRUI1RcYiOfYkCWrUJrtNhpwSovUO1UqNDtXeoQKrR4cjcHBgcO2wdBkXGYW-wdQFNVK13_9C_qfR75Q</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1835629507</pqid></control><display><type>article</type><title>Microdevice with integrated multi-enzyme sensors for the measurement of pork freshness</title><source>ScienceDirect Freedom Collection</source><creator>Qiu, Xiaoli ; Itoh, Daisuke ; Satake, Takaaki ; Suzuki, Hiroaki</creator><creatorcontrib>Qiu, Xiaoli ; Itoh, Daisuke ; Satake, Takaaki ; Suzuki, Hiroaki</creatorcontrib><description>An electrochemical microdevice for measuring pork freshness was developed based on the value of measurement indicators—K, Ki, and H. Four sensors were integrated to measure the sum of the concentrations appearing in the equations that define the K, Ki, and H values. With standard solutions, the correlation coefficients for sensors 1–4 were 0.888, 0.979, 0.816, and 0.828, respectively. Each sensor could complete one measurement in 2min. A good correlation was obtained between the K values measured by the proposed microdevice and by ultra-performance liquid chromatography. Based on the sensor responses obtained with real pork extract samples, the R2 value between the K and Ki values was 0.843, while that between the K and H values was only 0.807 during a 15-day storage period.</description><identifier>ISSN: 0925-4005</identifier><identifier>EISSN: 1873-3077</identifier><identifier>DOI: 10.1016/j.snb.2016.05.074</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>Actuators ; ATP-related compounds ; Correlation analysis ; Enzyme ; Freshness ; K value ; Liquid chromatography ; Mathematical analysis ; Pork ; Sensors</subject><ispartof>Sensors and actuators. B, Chemical, 2016-11, Vol.235, p.535-540</ispartof><rights>2016 Elsevier B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c330t-e06924b0d0a749d9afd1589c49eea16fc81b4092a8acc52c4d528a66e2c8ceff3</citedby><cites>FETCH-LOGICAL-c330t-e06924b0d0a749d9afd1589c49eea16fc81b4092a8acc52c4d528a66e2c8ceff3</cites><orcidid>0000-0002-3535-703X</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>Qiu, Xiaoli</creatorcontrib><creatorcontrib>Itoh, Daisuke</creatorcontrib><creatorcontrib>Satake, Takaaki</creatorcontrib><creatorcontrib>Suzuki, Hiroaki</creatorcontrib><title>Microdevice with integrated multi-enzyme sensors for the measurement of pork freshness</title><title>Sensors and actuators. B, Chemical</title><description>An electrochemical microdevice for measuring pork freshness was developed based on the value of measurement indicators—K, Ki, and H. Four sensors were integrated to measure the sum of the concentrations appearing in the equations that define the K, Ki, and H values. With standard solutions, the correlation coefficients for sensors 1–4 were 0.888, 0.979, 0.816, and 0.828, respectively. Each sensor could complete one measurement in 2min. A good correlation was obtained between the K values measured by the proposed microdevice and by ultra-performance liquid chromatography. Based on the sensor responses obtained with real pork extract samples, the R2 value between the K and Ki values was 0.843, while that between the K and H values was only 0.807 during a 15-day storage period.</description><subject>Actuators</subject><subject>ATP-related compounds</subject><subject>Correlation analysis</subject><subject>Enzyme</subject><subject>Freshness</subject><subject>K value</subject><subject>Liquid chromatography</subject><subject>Mathematical analysis</subject><subject>Pork</subject><subject>Sensors</subject><issn>0925-4005</issn><issn>1873-3077</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><recordid>eNp9kD1PwzAQhi0EEqXwA9g8siSckzgfYkIVX1IRC7BarnOmLk1cfE5R-fWkKjPT3fA-p3sfxi4FpAJEeb1KqV-k2bimIFOoiiM2EXWVJzlU1TGbQJPJpACQp-yMaAUARV7ChL0_OxN8i1tnkH-7uOSuj_gRdMSWd8M6ugT7n12HnLAnH4hbH3hcIu9Q0xCwwz5yb_nGh09uA9KyR6JzdmL1mvDib07Z2_3d6-wxmb88PM1u54nJc4gJQtlkxQJa0FXRtI22rZB1Y4oGUYvSmlosivF1XWtjZGaKVma1LkvMTG3Q2nzKrg53N8F_DUhRdY4Mrte6Rz-QEnUuy6yRUI1RcYiOfYkCWrUJrtNhpwSovUO1UqNDtXeoQKrR4cjcHBgcO2wdBkXGYW-wdQFNVK13_9C_qfR75Q</recordid><startdate>20161101</startdate><enddate>20161101</enddate><creator>Qiu, Xiaoli</creator><creator>Itoh, Daisuke</creator><creator>Satake, Takaaki</creator><creator>Suzuki, Hiroaki</creator><general>Elsevier B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7SR</scope><scope>7TB</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>FR3</scope><scope>JG9</scope><scope>L7M</scope><orcidid>https://orcid.org/0000-0002-3535-703X</orcidid></search><sort><creationdate>20161101</creationdate><title>Microdevice with integrated multi-enzyme sensors for the measurement of pork freshness</title><author>Qiu, Xiaoli ; Itoh, Daisuke ; Satake, Takaaki ; Suzuki, Hiroaki</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c330t-e06924b0d0a749d9afd1589c49eea16fc81b4092a8acc52c4d528a66e2c8ceff3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Actuators</topic><topic>ATP-related compounds</topic><topic>Correlation analysis</topic><topic>Enzyme</topic><topic>Freshness</topic><topic>K value</topic><topic>Liquid chromatography</topic><topic>Mathematical analysis</topic><topic>Pork</topic><topic>Sensors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Qiu, Xiaoli</creatorcontrib><creatorcontrib>Itoh, Daisuke</creatorcontrib><creatorcontrib>Satake, Takaaki</creatorcontrib><creatorcontrib>Suzuki, Hiroaki</creatorcontrib><collection>CrossRef</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Sensors and actuators. B, Chemical</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Qiu, Xiaoli</au><au>Itoh, Daisuke</au><au>Satake, Takaaki</au><au>Suzuki, Hiroaki</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Microdevice with integrated multi-enzyme sensors for the measurement of pork freshness</atitle><jtitle>Sensors and actuators. B, Chemical</jtitle><date>2016-11-01</date><risdate>2016</risdate><volume>235</volume><spage>535</spage><epage>540</epage><pages>535-540</pages><issn>0925-4005</issn><eissn>1873-3077</eissn><abstract>An electrochemical microdevice for measuring pork freshness was developed based on the value of measurement indicators—K, Ki, and H. Four sensors were integrated to measure the sum of the concentrations appearing in the equations that define the K, Ki, and H values. With standard solutions, the correlation coefficients for sensors 1–4 were 0.888, 0.979, 0.816, and 0.828, respectively. Each sensor could complete one measurement in 2min. A good correlation was obtained between the K values measured by the proposed microdevice and by ultra-performance liquid chromatography. Based on the sensor responses obtained with real pork extract samples, the R2 value between the K and Ki values was 0.843, while that between the K and H values was only 0.807 during a 15-day storage period.</abstract><pub>Elsevier B.V</pub><doi>10.1016/j.snb.2016.05.074</doi><tpages>6</tpages><orcidid>https://orcid.org/0000-0002-3535-703X</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0925-4005
ispartof Sensors and actuators. B, Chemical, 2016-11, Vol.235, p.535-540
issn 0925-4005
1873-3077
language eng
recordid cdi_proquest_miscellaneous_1835629507
source ScienceDirect Freedom Collection
subjects Actuators
ATP-related compounds
Correlation analysis
Enzyme
Freshness
K value
Liquid chromatography
Mathematical analysis
Pork
Sensors
title Microdevice with integrated multi-enzyme sensors for the measurement of pork freshness
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-23T23%3A51%3A48IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Microdevice%20with%20integrated%20multi-enzyme%20sensors%20for%20the%20measurement%20of%20pork%20freshness&rft.jtitle=Sensors%20and%20actuators.%20B,%20Chemical&rft.au=Qiu,%20Xiaoli&rft.date=2016-11-01&rft.volume=235&rft.spage=535&rft.epage=540&rft.pages=535-540&rft.issn=0925-4005&rft.eissn=1873-3077&rft_id=info:doi/10.1016/j.snb.2016.05.074&rft_dat=%3Cproquest_cross%3E1835629507%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c330t-e06924b0d0a749d9afd1589c49eea16fc81b4092a8acc52c4d528a66e2c8ceff3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1835629507&rft_id=info:pmid/&rfr_iscdi=true