Loading…

The effect of influence quantities and detector orientation on small-field patient-specific IMRT QA: comparison of measurements with various ionization chambers

Intensity-modulated radiation therapy (IMRT) requires a patient-specific quality assurance (QA) program to validate the treatment plan and a high level of dosimetric accuracy in the treatment delivery. Dosimetric verification generally consists of both absolute- and relative-dose measurements in a p...

Full description

Saved in:
Bibliographic Details
Published in:Radiological physics and technology 2017-06, Vol.10 (2), p.195-203
Main Authors: Godson, Henry Finlay, Manickam, Ravikumar, Saminathan, Sathiyan, Ganesh, Kadirampatti Mani, Ponmalar, Retna
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-LOGICAL-c348t-727823ee50c78e38deafb8cae3cba418728e24d0c625a6824609c8c8c54ee3d43
container_end_page 203
container_issue 2
container_start_page 195
container_title Radiological physics and technology
container_volume 10
creator Godson, Henry Finlay
Manickam, Ravikumar
Saminathan, Sathiyan
Ganesh, Kadirampatti Mani
Ponmalar, Retna
description Intensity-modulated radiation therapy (IMRT) requires a patient-specific quality assurance (QA) program to validate the treatment plan and a high level of dosimetric accuracy in the treatment delivery. Dosimetric verification generally consists of both absolute- and relative-dose measurements in a phantom using ionization chambers. Measurements were carried out with three different ionization chambers (Scanditronix FC 65G, Exradin A18, and PTW PinPoint 31014) to assess the effects of influence quantities such as the stability, pre- and post-irradiation leakage, stem effect, polarity, and ion recombination on the IMRT point-dose verification with two different orientations. The Exradin A18 and PTW PinPoint ion chambers demonstrated noticeable leakage to magnitudes of 0.6 and 1.2%, whereas negligible leakage was observed with FC 65G ion chamber. Maximum deviations of 0.5 and 0.6% were noticed for the smallest field owing to the ion recombination effect with the PTW PinPoint ion chamber in the parallel and perpendicular orientations, respectively. The calculated total uncertainties of all influence quantities for the FC 65G, A18, and PTW PinPoint ion chambers were 0.5, 0.7, and 1.3%, respectively. The uncertainties determined for each chamber were incorporated into the point-dose measurements of 30 head and neck patient-specific QA plans, and the variation was found to be within ±3%. The magnitude of the leakage in a small-volume ion chamber indicated the significance of incorporating the correction factors in the absolute-dose measurement. A paired t test analysis indicated that the influence quantities significantly affect the point-dose measurements in the patient-specific IMRT QA.
doi_str_mv 10.1007/s12194-016-0385-y
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1845816783</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1845816783</sourcerecordid><originalsourceid>FETCH-LOGICAL-c348t-727823ee50c78e38deafb8cae3cba418728e24d0c625a6824609c8c8c54ee3d43</originalsourceid><addsrcrecordid>eNp1kdtqFTEUhoMotlYfwBsJeOPNaE4zk-1dKR4KFVG21yE7s-JOmUmmSaayfRof1bWZWkSQBHJY3_9nkZ-Q55y95oz1bwoXfKMaxruGSd02hwfklOuuxZPiD-_3Up6QJ6VcM9ZxIcRjciL6DRowfkp-bfdAwXtwlSZPQ_TjAtEBvVlsrKEGKNTGgQ5QEUmZphwgVltDihRnmew4Nj7AONAZb7HWlBlc8MHRy09ft_TL-Vvq0jTbHMpR4-kEtiwZJmQL_RHqnt5iMS2Fomn4uXq7vZ12kMtT8sjbscCzu_WMfHv_bnvxsbn6_OHy4vyqcVLp2vSi10ICtMz1GqQewPqddhak21nFdS80CDUw14nWdlqojm2cxtEqADkoeUZerb5zTjcLlGqmUByMo42ArRmuVat512uJ6Mt_0Ou05IjdGY7_KpHrOVJ8pVxOpWTwZs5hsvlgODPH-Mwan8H4zDE-c0DNizvnZTfBcK_4kxcCYgUKluJ3yH89_V_X3xu5qN0</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1910358171</pqid></control><display><type>article</type><title>The effect of influence quantities and detector orientation on small-field patient-specific IMRT QA: comparison of measurements with various ionization chambers</title><source>Springer Nature</source><creator>Godson, Henry Finlay ; Manickam, Ravikumar ; Saminathan, Sathiyan ; Ganesh, Kadirampatti Mani ; Ponmalar, Retna</creator><creatorcontrib>Godson, Henry Finlay ; Manickam, Ravikumar ; Saminathan, Sathiyan ; Ganesh, Kadirampatti Mani ; Ponmalar, Retna</creatorcontrib><description>Intensity-modulated radiation therapy (IMRT) requires a patient-specific quality assurance (QA) program to validate the treatment plan and a high level of dosimetric accuracy in the treatment delivery. Dosimetric verification generally consists of both absolute- and relative-dose measurements in a phantom using ionization chambers. Measurements were carried out with three different ionization chambers (Scanditronix FC 65G, Exradin A18, and PTW PinPoint 31014) to assess the effects of influence quantities such as the stability, pre- and post-irradiation leakage, stem effect, polarity, and ion recombination on the IMRT point-dose verification with two different orientations. The Exradin A18 and PTW PinPoint ion chambers demonstrated noticeable leakage to magnitudes of 0.6 and 1.2%, whereas negligible leakage was observed with FC 65G ion chamber. Maximum deviations of 0.5 and 0.6% were noticed for the smallest field owing to the ion recombination effect with the PTW PinPoint ion chamber in the parallel and perpendicular orientations, respectively. The calculated total uncertainties of all influence quantities for the FC 65G, A18, and PTW PinPoint ion chambers were 0.5, 0.7, and 1.3%, respectively. The uncertainties determined for each chamber were incorporated into the point-dose measurements of 30 head and neck patient-specific QA plans, and the variation was found to be within ±3%. The magnitude of the leakage in a small-volume ion chamber indicated the significance of incorporating the correction factors in the absolute-dose measurement. A paired t test analysis indicated that the influence quantities significantly affect the point-dose measurements in the patient-specific IMRT QA.</description><identifier>ISSN: 1865-0333</identifier><identifier>EISSN: 1865-0341</identifier><identifier>DOI: 10.1007/s12194-016-0385-y</identifier><identifier>PMID: 27910001</identifier><language>eng</language><publisher>Singapore: Springer Singapore</publisher><subject>Humans ; Imaging ; Ion recombination ; Ionization chambers ; Irradiation ; Leakage ; Mathematical analysis ; Medical and Radiation Physics ; Medicine ; Medicine &amp; Public Health ; Nuclear Medicine ; Orientation ; Polarity ; Precision Medicine ; Quality assurance ; Quality Assurance, Health Care ; Radiation therapy ; Radiology ; Radiometry - instrumentation ; Radiotherapy ; Radiotherapy, Intensity-Modulated ; Stability analysis ; Uncertainty</subject><ispartof>Radiological physics and technology, 2017-06, Vol.10 (2), p.195-203</ispartof><rights>Japanese Society of Radiological Technology and Japan Society of Medical Physics 2016</rights><rights>Copyright Springer Science &amp; Business Media 2017</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c348t-727823ee50c78e38deafb8cae3cba418728e24d0c625a6824609c8c8c54ee3d43</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27922,27923</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/27910001$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Godson, Henry Finlay</creatorcontrib><creatorcontrib>Manickam, Ravikumar</creatorcontrib><creatorcontrib>Saminathan, Sathiyan</creatorcontrib><creatorcontrib>Ganesh, Kadirampatti Mani</creatorcontrib><creatorcontrib>Ponmalar, Retna</creatorcontrib><title>The effect of influence quantities and detector orientation on small-field patient-specific IMRT QA: comparison of measurements with various ionization chambers</title><title>Radiological physics and technology</title><addtitle>Radiol Phys Technol</addtitle><addtitle>Radiol Phys Technol</addtitle><description>Intensity-modulated radiation therapy (IMRT) requires a patient-specific quality assurance (QA) program to validate the treatment plan and a high level of dosimetric accuracy in the treatment delivery. Dosimetric verification generally consists of both absolute- and relative-dose measurements in a phantom using ionization chambers. Measurements were carried out with three different ionization chambers (Scanditronix FC 65G, Exradin A18, and PTW PinPoint 31014) to assess the effects of influence quantities such as the stability, pre- and post-irradiation leakage, stem effect, polarity, and ion recombination on the IMRT point-dose verification with two different orientations. The Exradin A18 and PTW PinPoint ion chambers demonstrated noticeable leakage to magnitudes of 0.6 and 1.2%, whereas negligible leakage was observed with FC 65G ion chamber. Maximum deviations of 0.5 and 0.6% were noticed for the smallest field owing to the ion recombination effect with the PTW PinPoint ion chamber in the parallel and perpendicular orientations, respectively. The calculated total uncertainties of all influence quantities for the FC 65G, A18, and PTW PinPoint ion chambers were 0.5, 0.7, and 1.3%, respectively. The uncertainties determined for each chamber were incorporated into the point-dose measurements of 30 head and neck patient-specific QA plans, and the variation was found to be within ±3%. The magnitude of the leakage in a small-volume ion chamber indicated the significance of incorporating the correction factors in the absolute-dose measurement. A paired t test analysis indicated that the influence quantities significantly affect the point-dose measurements in the patient-specific IMRT QA.</description><subject>Humans</subject><subject>Imaging</subject><subject>Ion recombination</subject><subject>Ionization chambers</subject><subject>Irradiation</subject><subject>Leakage</subject><subject>Mathematical analysis</subject><subject>Medical and Radiation Physics</subject><subject>Medicine</subject><subject>Medicine &amp; Public Health</subject><subject>Nuclear Medicine</subject><subject>Orientation</subject><subject>Polarity</subject><subject>Precision Medicine</subject><subject>Quality assurance</subject><subject>Quality Assurance, Health Care</subject><subject>Radiation therapy</subject><subject>Radiology</subject><subject>Radiometry - instrumentation</subject><subject>Radiotherapy</subject><subject>Radiotherapy, Intensity-Modulated</subject><subject>Stability analysis</subject><subject>Uncertainty</subject><issn>1865-0333</issn><issn>1865-0341</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNp1kdtqFTEUhoMotlYfwBsJeOPNaE4zk-1dKR4KFVG21yE7s-JOmUmmSaayfRof1bWZWkSQBHJY3_9nkZ-Q55y95oz1bwoXfKMaxruGSd02hwfklOuuxZPiD-_3Up6QJ6VcM9ZxIcRjciL6DRowfkp-bfdAwXtwlSZPQ_TjAtEBvVlsrKEGKNTGgQ5QEUmZphwgVltDihRnmew4Nj7AONAZb7HWlBlc8MHRy09ft_TL-Vvq0jTbHMpR4-kEtiwZJmQL_RHqnt5iMS2Fomn4uXq7vZ12kMtT8sjbscCzu_WMfHv_bnvxsbn6_OHy4vyqcVLp2vSi10ICtMz1GqQewPqddhak21nFdS80CDUw14nWdlqojm2cxtEqADkoeUZerb5zTjcLlGqmUByMo42ArRmuVat512uJ6Mt_0Ou05IjdGY7_KpHrOVJ8pVxOpWTwZs5hsvlgODPH-Mwan8H4zDE-c0DNizvnZTfBcK_4kxcCYgUKluJ3yH89_V_X3xu5qN0</recordid><startdate>20170601</startdate><enddate>20170601</enddate><creator>Godson, Henry Finlay</creator><creator>Manickam, Ravikumar</creator><creator>Saminathan, Sathiyan</creator><creator>Ganesh, Kadirampatti Mani</creator><creator>Ponmalar, Retna</creator><general>Springer Singapore</general><general>Springer Nature B.V</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20170601</creationdate><title>The effect of influence quantities and detector orientation on small-field patient-specific IMRT QA: comparison of measurements with various ionization chambers</title><author>Godson, Henry Finlay ; Manickam, Ravikumar ; Saminathan, Sathiyan ; Ganesh, Kadirampatti Mani ; Ponmalar, Retna</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c348t-727823ee50c78e38deafb8cae3cba418728e24d0c625a6824609c8c8c54ee3d43</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Humans</topic><topic>Imaging</topic><topic>Ion recombination</topic><topic>Ionization chambers</topic><topic>Irradiation</topic><topic>Leakage</topic><topic>Mathematical analysis</topic><topic>Medical and Radiation Physics</topic><topic>Medicine</topic><topic>Medicine &amp; Public Health</topic><topic>Nuclear Medicine</topic><topic>Orientation</topic><topic>Polarity</topic><topic>Precision Medicine</topic><topic>Quality assurance</topic><topic>Quality Assurance, Health Care</topic><topic>Radiation therapy</topic><topic>Radiology</topic><topic>Radiometry - instrumentation</topic><topic>Radiotherapy</topic><topic>Radiotherapy, Intensity-Modulated</topic><topic>Stability analysis</topic><topic>Uncertainty</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Godson, Henry Finlay</creatorcontrib><creatorcontrib>Manickam, Ravikumar</creatorcontrib><creatorcontrib>Saminathan, Sathiyan</creatorcontrib><creatorcontrib>Ganesh, Kadirampatti Mani</creatorcontrib><creatorcontrib>Ponmalar, Retna</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Radiological physics and technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Godson, Henry Finlay</au><au>Manickam, Ravikumar</au><au>Saminathan, Sathiyan</au><au>Ganesh, Kadirampatti Mani</au><au>Ponmalar, Retna</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The effect of influence quantities and detector orientation on small-field patient-specific IMRT QA: comparison of measurements with various ionization chambers</atitle><jtitle>Radiological physics and technology</jtitle><stitle>Radiol Phys Technol</stitle><addtitle>Radiol Phys Technol</addtitle><date>2017-06-01</date><risdate>2017</risdate><volume>10</volume><issue>2</issue><spage>195</spage><epage>203</epage><pages>195-203</pages><issn>1865-0333</issn><eissn>1865-0341</eissn><abstract>Intensity-modulated radiation therapy (IMRT) requires a patient-specific quality assurance (QA) program to validate the treatment plan and a high level of dosimetric accuracy in the treatment delivery. Dosimetric verification generally consists of both absolute- and relative-dose measurements in a phantom using ionization chambers. Measurements were carried out with three different ionization chambers (Scanditronix FC 65G, Exradin A18, and PTW PinPoint 31014) to assess the effects of influence quantities such as the stability, pre- and post-irradiation leakage, stem effect, polarity, and ion recombination on the IMRT point-dose verification with two different orientations. The Exradin A18 and PTW PinPoint ion chambers demonstrated noticeable leakage to magnitudes of 0.6 and 1.2%, whereas negligible leakage was observed with FC 65G ion chamber. Maximum deviations of 0.5 and 0.6% were noticed for the smallest field owing to the ion recombination effect with the PTW PinPoint ion chamber in the parallel and perpendicular orientations, respectively. The calculated total uncertainties of all influence quantities for the FC 65G, A18, and PTW PinPoint ion chambers were 0.5, 0.7, and 1.3%, respectively. The uncertainties determined for each chamber were incorporated into the point-dose measurements of 30 head and neck patient-specific QA plans, and the variation was found to be within ±3%. The magnitude of the leakage in a small-volume ion chamber indicated the significance of incorporating the correction factors in the absolute-dose measurement. A paired t test analysis indicated that the influence quantities significantly affect the point-dose measurements in the patient-specific IMRT QA.</abstract><cop>Singapore</cop><pub>Springer Singapore</pub><pmid>27910001</pmid><doi>10.1007/s12194-016-0385-y</doi><tpages>9</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1865-0333
ispartof Radiological physics and technology, 2017-06, Vol.10 (2), p.195-203
issn 1865-0333
1865-0341
language eng
recordid cdi_proquest_miscellaneous_1845816783
source Springer Nature
subjects Humans
Imaging
Ion recombination
Ionization chambers
Irradiation
Leakage
Mathematical analysis
Medical and Radiation Physics
Medicine
Medicine & Public Health
Nuclear Medicine
Orientation
Polarity
Precision Medicine
Quality assurance
Quality Assurance, Health Care
Radiation therapy
Radiology
Radiometry - instrumentation
Radiotherapy
Radiotherapy, Intensity-Modulated
Stability analysis
Uncertainty
title The effect of influence quantities and detector orientation on small-field patient-specific IMRT QA: comparison of measurements with various ionization chambers
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-14T11%3A33%3A02IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20effect%20of%20influence%20quantities%20and%20detector%20orientation%20on%20small-field%20patient-specific%20IMRT%20QA:%20comparison%20of%20measurements%20with%20various%20ionization%20chambers&rft.jtitle=Radiological%20physics%20and%20technology&rft.au=Godson,%20Henry%20Finlay&rft.date=2017-06-01&rft.volume=10&rft.issue=2&rft.spage=195&rft.epage=203&rft.pages=195-203&rft.issn=1865-0333&rft.eissn=1865-0341&rft_id=info:doi/10.1007/s12194-016-0385-y&rft_dat=%3Cproquest_cross%3E1845816783%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c348t-727823ee50c78e38deafb8cae3cba418728e24d0c625a6824609c8c8c54ee3d43%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1910358171&rft_id=info:pmid/27910001&rfr_iscdi=true