Seismic Earth Pressures on Retaining Structures and Basement Walls in Cohesionless Soils
AbstractObservations of the performance of basement walls and retaining structures in recent earthquakes show that failures of basement or deep-excavation walls in earthquakes are rare even if the structures were not designed for the actual magnitude of the earthquake loading. For instance, no signi...
Saved in:
Published in: | Journal of geotechnical and geoenvironmental engineering 2016-10, Vol.142 (10) |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | AbstractObservations of the performance of basement walls and retaining structures in recent earthquakes show that failures of basement or deep-excavation walls in earthquakes are rare even if the structures were not designed for the actual magnitude of the earthquake loading. For instance, no significant damage or failures of retaining structures occurred in the recent Wenchuan earthquake in China (2008) or in the subduction earthquakes in Chile (2010) and Japan (2011). To develop a better understanding of the distribution and magnitude of the seismic earth pressures on cantilever retaining structures, a series of centrifuge experiments were performed on model retaining and basement structures with medium dense cohesionless backfill. This paper provides a general overview of the research program and its results. Two sets of centrifuge-scale experiments were carried out on the centrifuge at the Center for Geotechnical Modeling at UC Davis. Three different types of prototype retaining structure were modeled in this research effort as follows: (1) a nondisplacing cross-braced (basement) structure with a stem stiffness of 5.92×1010 lb-in.2 per ft width (5.57×1005 kN-m2 per m width) and 1.04×1010 lb-in.2 per ft width (9.79×1004 kN-m2 per m width); (2) a nondisplacing U-shaped cantilever structure with a stem stiffness of 5.92 and 1.04×1010 lb-in.2 per ft width (9.79×1004 kN-m2 per m width); and (3) a free standing, cantilever retaining wall with a stem stiffness of 2.4×1010 lb-in.2 per ft width (2.26×1005 kN-m2 per m width). Overall, for the structures examined [i.e., wall heights in the range 6.1–9.15 m (20–30 ft)], the centrifuge data consistently show that the maximum dynamic earth pressure increases with depth and can be reasonably approximated by a triangular distribution. This suggests that the result of the dynamic earth pressure increment acts near 0.33H above the footing as opposed to 0.5–0.6 H recommended by most current design procedures. The current data also suggest that cantilever walls can resist ground accelerations up to 0.4 g if designed with an adequate static factor of safety. |
---|---|
ISSN: | 1090-0241 1943-5606 |