Loading…

Extensibility and Distensibility of the Thoracic Aorta in Patients with Aneurysm

Objectives Reference values of aortic deformation during the cardiac cycle can be valuable for the pre-operative planning of thoracic endovascular aortic repair (TEVAR) and for facilitating computational fluid dynamics. This study aimed to quantify normal aortic extensibility (longitudinal extension...

Full description

Saved in:
Bibliographic Details
Published in:European journal of vascular and endovascular surgery 2017-02, Vol.53 (2), p.199-205
Main Authors: de Beaufort, H.W.L, Nauta, F.J.H, Conti, M, Cellitti, E, Trentin, C, Faggiano, E, van Bogerijen, G.H.W, Figueroa, C.A, Moll, F.L, van Herwaarden, J.A, Auricchio, F, Trimarchi, S
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Objectives Reference values of aortic deformation during the cardiac cycle can be valuable for the pre-operative planning of thoracic endovascular aortic repair (TEVAR) and for facilitating computational fluid dynamics. This study aimed to quantify normal aortic extensibility (longitudinal extension) and distensibility (radial expansion), as well as pulsatile strain, in a group of 10 (>60 years) individuals with abdominal or thoracic aortic aneurysms. Methods ECG gated CT images of the thoracic aorta were reconstructed into virtual 3D models of aortic geometry. The centre lumen line length of the thoracic aorta and three longitudinal segments, and the aortic diameter and luminal areas of four radial intersections were extracted with a dedicated software script to calculate extensibility, longitudinal strain, distensibility, and circumferential area strain. Results Mean extensibility and longitudinal strain of the entire thoracic aorta were 3.5 [1.3–6.8] × 10−3  N−1 , and 2.7 [1.0–4.5]%, respectively. Extensibility and longitudinal strain were most pronounced in the ascending aorta (20.6 [5.7–36.2] × 10−3  N−1 and 15.9 [6.6–31.9]%) and smallest in the descending aorta (4.4 [1.6–12.3] × 10−3  N−1 and 2.2 [0.7–4.7]%). Mean distensibility and circumferential area strain were most pronounced at the sinotubular junction (1.7 [0.5–2.9] × 10−3  mmHg−1 and 11.3 [3.3–18.5]%, respectively). Distensibility varied between 0.9 [0.3–2.5] × 10−3  mmHg−1 and 1.2 [0.3–3.3] × 10−3  mmHg−1 at the intersections in the aortic arch and descending aorta. Conclusions Pulsatile deformations in both longitudinal and circumferential directions are considerable throughout the thoracic aorta. These findings may have implications for pre-operative TEVAR planning and highlight the need for devices that can mimic the significant aortic longitudinal and circumferential strains.
ISSN:1078-5884
1532-2165
DOI:10.1016/j.ejvs.2016.11.018