Loading…

The Development of a Representative Porcine Early-Onset Scoliosis Model With a Standalone Posterior Spinal Tether

Abstract Study Design In vivo analysis in a porcine model. Objectives To develop a porcine experimental scoliosis model representative of early-onset scoliosis (EOS) with the use of a radiopaque ultra-high molecular weight polyethylene (UHMWPE) posterior spinal tether. Summary of Background Data Lar...

Full description

Saved in:
Bibliographic Details
Published in:Spine deformity 2017, Vol.5 (1), p.2-10
Main Authors: Bogie, R., MD, Roth, A.K., MSc, Willems, P.C., MD, PhD, Weegen, vd W., PhD, Arts, J.J., PhD, van Rhijn, L.W., MD, PhD
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c4142-8224feade58f5e8aa7f49cd465cc461fa116859268ff2954ff0f9e642b915ea83
cites cdi_FETCH-LOGICAL-c4142-8224feade58f5e8aa7f49cd465cc461fa116859268ff2954ff0f9e642b915ea83
container_end_page 10
container_issue 1
container_start_page 2
container_title Spine deformity
container_volume 5
creator Bogie, R., MD
Roth, A.K., MSc
Willems, P.C., MD, PhD
Weegen, vd W., PhD
Arts, J.J., PhD
van Rhijn, L.W., MD, PhD
description Abstract Study Design In vivo analysis in a porcine model. Objectives To develop a porcine experimental scoliosis model representative of early-onset scoliosis (EOS) with the use of a radiopaque ultra-high molecular weight polyethylene (UHMWPE) posterior spinal tether. Summary of Background Data Large animal experimental scoliosis models with substantial growth potential are needed to test new fusionless scoliosis correction techniques. Previously described scoliosis models involve rib procedures, which violate the thoracic cage and affect subsequent corrective procedures. Models omitting these rib procedures have experienced difficulties in producing persistent three-dimensional structural deformities representative of EOS. Methods Scoliosis was induced in 14 immature pigs using an asymmetric posterior radiopaque UHMWPE spinal tether fixated to an offset device at lumbar and thoracic levels. Radiographs were taken at 2-week intervals, and frontal and sagittal Cobb angles were measured. A tether release was performed at the 10-week follow-up, and the animals were observed for another 10 weeks. Results Four animals had complications (infections and/or screw breakout) and were excluded from the study. Eight animals developed progressive curves with a mean frontal Cobb angle of 62°. A thoracic lordosis (34°) and a thoracolumbar kyphosis (22°) formed. CT analysis, acquired prior to tether release, showed a mean vertebral rotation of 37° at the apex with a mean vertebral wedge angle of 10°. After tether release, the frontal Cobb angles decreased to 46° at the 20-week follow-up. Sagittal curvature was not substantially affected after tether release. Conclusions We describe a large animal scoliosis model, which exhibits a substantial deformity in three planes without the use of rib procedures additional to a posterior spinal tether. The created deformities showed persistence after tether release. With the management of infection and enhancement of instrumentation stability, the creation of a valid model for testing new devices in fusionless scoliosis surgery seems feasible. Level of Evidence Level V.
doi_str_mv 10.1016/j.jspd.2016.09.002
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1854616354</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>1_s2_0_S2212134X16301113</els_id><sourcerecordid>1854616354</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4142-8224feade58f5e8aa7f49cd465cc461fa116859268ff2954ff0f9e642b915ea83</originalsourceid><addsrcrecordid>eNp9kl1rFDEUhgdRbKn9A15ILr2ZMclkxgyIILV-QKXiruhdSDMnbsZsMs3JLuy_N8PWCl40N0nI-7yEh1NVzxltGGX9q6mZcB4bXs4NHRpK-aPqlHPGa9Z28vH9Wfw8qc4RJ1qWlILJ7ml1wiVtZT_Q0-p2vQHyHvbg47yFkEm0RJNvMCfActXZ7YF8jcm4AORSJ3-orwNCJisTvYvokHyJI3jyw-VNIVdZh1H7GBYKMyQXE1nNLmhP1pA3kJ5VT6z2COd3-1n1_cPl-uJTfXX98fPFu6vaCCZ4LTkXFvQInbQdSK1fWzGYUfSdMaJnVjPWy27gvbSWD52wltoBesFvBtaBlu1Z9fLYO6d4uwPMauvQgPc6QNyhKiZKT992okT5MWpSRExg1ZzcVqeDYlQtttWkFttqsa3ooIrtAr2469_dbGG8R_66LYH2GMDyFH5BUlPcpSICH659c6SguNm7QqFxEAyMLoHJaozuYfztf7jxLjij_W84AP77gUKuqFotU7IMSRFBGWNt-wegyrcH</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1854616354</pqid></control><display><type>article</type><title>The Development of a Representative Porcine Early-Onset Scoliosis Model With a Standalone Posterior Spinal Tether</title><source>Springer Link</source><creator>Bogie, R., MD ; Roth, A.K., MSc ; Willems, P.C., MD, PhD ; Weegen, vd W., PhD ; Arts, J.J., PhD ; van Rhijn, L.W., MD, PhD</creator><creatorcontrib>Bogie, R., MD ; Roth, A.K., MSc ; Willems, P.C., MD, PhD ; Weegen, vd W., PhD ; Arts, J.J., PhD ; van Rhijn, L.W., MD, PhD</creatorcontrib><description>Abstract Study Design In vivo analysis in a porcine model. Objectives To develop a porcine experimental scoliosis model representative of early-onset scoliosis (EOS) with the use of a radiopaque ultra-high molecular weight polyethylene (UHMWPE) posterior spinal tether. Summary of Background Data Large animal experimental scoliosis models with substantial growth potential are needed to test new fusionless scoliosis correction techniques. Previously described scoliosis models involve rib procedures, which violate the thoracic cage and affect subsequent corrective procedures. Models omitting these rib procedures have experienced difficulties in producing persistent three-dimensional structural deformities representative of EOS. Methods Scoliosis was induced in 14 immature pigs using an asymmetric posterior radiopaque UHMWPE spinal tether fixated to an offset device at lumbar and thoracic levels. Radiographs were taken at 2-week intervals, and frontal and sagittal Cobb angles were measured. A tether release was performed at the 10-week follow-up, and the animals were observed for another 10 weeks. Results Four animals had complications (infections and/or screw breakout) and were excluded from the study. Eight animals developed progressive curves with a mean frontal Cobb angle of 62°. A thoracic lordosis (34°) and a thoracolumbar kyphosis (22°) formed. CT analysis, acquired prior to tether release, showed a mean vertebral rotation of 37° at the apex with a mean vertebral wedge angle of 10°. After tether release, the frontal Cobb angles decreased to 46° at the 20-week follow-up. Sagittal curvature was not substantially affected after tether release. Conclusions We describe a large animal scoliosis model, which exhibits a substantial deformity in three planes without the use of rib procedures additional to a posterior spinal tether. The created deformities showed persistence after tether release. With the management of infection and enhancement of instrumentation stability, the creation of a valid model for testing new devices in fusionless scoliosis surgery seems feasible. Level of Evidence Level V.</description><identifier>ISSN: 2212-134X</identifier><identifier>EISSN: 2212-1358</identifier><identifier>DOI: 10.1016/j.jspd.2016.09.002</identifier><identifier>PMID: 28038690</identifier><language>eng</language><publisher>Cham: Elsevier Inc</publisher><subject>Basic Science ; Early-onset scoliosis ; Medicine &amp; Public Health ; Orthopedics ; Radiopaque UHMWPE tether ; Rotation ; Scoliosis model ; Wedging</subject><ispartof>Spine deformity, 2017, Vol.5 (1), p.2-10</ispartof><rights>Scoliosis Research Society</rights><rights>2016 Scoliosis Research Society</rights><rights>Scoliosis Research Society 2016</rights><rights>Copyright © 2016 Scoliosis Research Society. Published by Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4142-8224feade58f5e8aa7f49cd465cc461fa116859268ff2954ff0f9e642b915ea83</citedby><cites>FETCH-LOGICAL-c4142-8224feade58f5e8aa7f49cd465cc461fa116859268ff2954ff0f9e642b915ea83</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,777,781,27905,27906</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/28038690$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Bogie, R., MD</creatorcontrib><creatorcontrib>Roth, A.K., MSc</creatorcontrib><creatorcontrib>Willems, P.C., MD, PhD</creatorcontrib><creatorcontrib>Weegen, vd W., PhD</creatorcontrib><creatorcontrib>Arts, J.J., PhD</creatorcontrib><creatorcontrib>van Rhijn, L.W., MD, PhD</creatorcontrib><title>The Development of a Representative Porcine Early-Onset Scoliosis Model With a Standalone Posterior Spinal Tether</title><title>Spine deformity</title><addtitle>Spine Deform</addtitle><addtitle>Spine Deform</addtitle><description>Abstract Study Design In vivo analysis in a porcine model. Objectives To develop a porcine experimental scoliosis model representative of early-onset scoliosis (EOS) with the use of a radiopaque ultra-high molecular weight polyethylene (UHMWPE) posterior spinal tether. Summary of Background Data Large animal experimental scoliosis models with substantial growth potential are needed to test new fusionless scoliosis correction techniques. Previously described scoliosis models involve rib procedures, which violate the thoracic cage and affect subsequent corrective procedures. Models omitting these rib procedures have experienced difficulties in producing persistent three-dimensional structural deformities representative of EOS. Methods Scoliosis was induced in 14 immature pigs using an asymmetric posterior radiopaque UHMWPE spinal tether fixated to an offset device at lumbar and thoracic levels. Radiographs were taken at 2-week intervals, and frontal and sagittal Cobb angles were measured. A tether release was performed at the 10-week follow-up, and the animals were observed for another 10 weeks. Results Four animals had complications (infections and/or screw breakout) and were excluded from the study. Eight animals developed progressive curves with a mean frontal Cobb angle of 62°. A thoracic lordosis (34°) and a thoracolumbar kyphosis (22°) formed. CT analysis, acquired prior to tether release, showed a mean vertebral rotation of 37° at the apex with a mean vertebral wedge angle of 10°. After tether release, the frontal Cobb angles decreased to 46° at the 20-week follow-up. Sagittal curvature was not substantially affected after tether release. Conclusions We describe a large animal scoliosis model, which exhibits a substantial deformity in three planes without the use of rib procedures additional to a posterior spinal tether. The created deformities showed persistence after tether release. With the management of infection and enhancement of instrumentation stability, the creation of a valid model for testing new devices in fusionless scoliosis surgery seems feasible. Level of Evidence Level V.</description><subject>Basic Science</subject><subject>Early-onset scoliosis</subject><subject>Medicine &amp; Public Health</subject><subject>Orthopedics</subject><subject>Radiopaque UHMWPE tether</subject><subject>Rotation</subject><subject>Scoliosis model</subject><subject>Wedging</subject><issn>2212-134X</issn><issn>2212-1358</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNp9kl1rFDEUhgdRbKn9A15ILr2ZMclkxgyIILV-QKXiruhdSDMnbsZsMs3JLuy_N8PWCl40N0nI-7yEh1NVzxltGGX9q6mZcB4bXs4NHRpK-aPqlHPGa9Z28vH9Wfw8qc4RJ1qWlILJ7ml1wiVtZT_Q0-p2vQHyHvbg47yFkEm0RJNvMCfActXZ7YF8jcm4AORSJ3-orwNCJisTvYvokHyJI3jyw-VNIVdZh1H7GBYKMyQXE1nNLmhP1pA3kJ5VT6z2COd3-1n1_cPl-uJTfXX98fPFu6vaCCZ4LTkXFvQInbQdSK1fWzGYUfSdMaJnVjPWy27gvbSWD52wltoBesFvBtaBlu1Z9fLYO6d4uwPMauvQgPc6QNyhKiZKT992okT5MWpSRExg1ZzcVqeDYlQtttWkFttqsa3ooIrtAr2469_dbGG8R_66LYH2GMDyFH5BUlPcpSICH659c6SguNm7QqFxEAyMLoHJaozuYfztf7jxLjij_W84AP77gUKuqFotU7IMSRFBGWNt-wegyrcH</recordid><startdate>2017</startdate><enddate>2017</enddate><creator>Bogie, R., MD</creator><creator>Roth, A.K., MSc</creator><creator>Willems, P.C., MD, PhD</creator><creator>Weegen, vd W., PhD</creator><creator>Arts, J.J., PhD</creator><creator>van Rhijn, L.W., MD, PhD</creator><general>Elsevier Inc</general><general>Springer International Publishing</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>2017</creationdate><title>The Development of a Representative Porcine Early-Onset Scoliosis Model With a Standalone Posterior Spinal Tether</title><author>Bogie, R., MD ; Roth, A.K., MSc ; Willems, P.C., MD, PhD ; Weegen, vd W., PhD ; Arts, J.J., PhD ; van Rhijn, L.W., MD, PhD</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4142-8224feade58f5e8aa7f49cd465cc461fa116859268ff2954ff0f9e642b915ea83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Basic Science</topic><topic>Early-onset scoliosis</topic><topic>Medicine &amp; Public Health</topic><topic>Orthopedics</topic><topic>Radiopaque UHMWPE tether</topic><topic>Rotation</topic><topic>Scoliosis model</topic><topic>Wedging</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bogie, R., MD</creatorcontrib><creatorcontrib>Roth, A.K., MSc</creatorcontrib><creatorcontrib>Willems, P.C., MD, PhD</creatorcontrib><creatorcontrib>Weegen, vd W., PhD</creatorcontrib><creatorcontrib>Arts, J.J., PhD</creatorcontrib><creatorcontrib>van Rhijn, L.W., MD, PhD</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Spine deformity</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bogie, R., MD</au><au>Roth, A.K., MSc</au><au>Willems, P.C., MD, PhD</au><au>Weegen, vd W., PhD</au><au>Arts, J.J., PhD</au><au>van Rhijn, L.W., MD, PhD</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The Development of a Representative Porcine Early-Onset Scoliosis Model With a Standalone Posterior Spinal Tether</atitle><jtitle>Spine deformity</jtitle><stitle>Spine Deform</stitle><addtitle>Spine Deform</addtitle><date>2017</date><risdate>2017</risdate><volume>5</volume><issue>1</issue><spage>2</spage><epage>10</epage><pages>2-10</pages><issn>2212-134X</issn><eissn>2212-1358</eissn><abstract>Abstract Study Design In vivo analysis in a porcine model. Objectives To develop a porcine experimental scoliosis model representative of early-onset scoliosis (EOS) with the use of a radiopaque ultra-high molecular weight polyethylene (UHMWPE) posterior spinal tether. Summary of Background Data Large animal experimental scoliosis models with substantial growth potential are needed to test new fusionless scoliosis correction techniques. Previously described scoliosis models involve rib procedures, which violate the thoracic cage and affect subsequent corrective procedures. Models omitting these rib procedures have experienced difficulties in producing persistent three-dimensional structural deformities representative of EOS. Methods Scoliosis was induced in 14 immature pigs using an asymmetric posterior radiopaque UHMWPE spinal tether fixated to an offset device at lumbar and thoracic levels. Radiographs were taken at 2-week intervals, and frontal and sagittal Cobb angles were measured. A tether release was performed at the 10-week follow-up, and the animals were observed for another 10 weeks. Results Four animals had complications (infections and/or screw breakout) and were excluded from the study. Eight animals developed progressive curves with a mean frontal Cobb angle of 62°. A thoracic lordosis (34°) and a thoracolumbar kyphosis (22°) formed. CT analysis, acquired prior to tether release, showed a mean vertebral rotation of 37° at the apex with a mean vertebral wedge angle of 10°. After tether release, the frontal Cobb angles decreased to 46° at the 20-week follow-up. Sagittal curvature was not substantially affected after tether release. Conclusions We describe a large animal scoliosis model, which exhibits a substantial deformity in three planes without the use of rib procedures additional to a posterior spinal tether. The created deformities showed persistence after tether release. With the management of infection and enhancement of instrumentation stability, the creation of a valid model for testing new devices in fusionless scoliosis surgery seems feasible. Level of Evidence Level V.</abstract><cop>Cham</cop><pub>Elsevier Inc</pub><pmid>28038690</pmid><doi>10.1016/j.jspd.2016.09.002</doi><tpages>9</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2212-134X
ispartof Spine deformity, 2017, Vol.5 (1), p.2-10
issn 2212-134X
2212-1358
language eng
recordid cdi_proquest_miscellaneous_1854616354
source Springer Link
subjects Basic Science
Early-onset scoliosis
Medicine & Public Health
Orthopedics
Radiopaque UHMWPE tether
Rotation
Scoliosis model
Wedging
title The Development of a Representative Porcine Early-Onset Scoliosis Model With a Standalone Posterior Spinal Tether
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-19T13%3A45%3A00IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20Development%20of%20a%20Representative%20Porcine%20Early-Onset%20Scoliosis%20Model%20With%20a%20Standalone%20Posterior%20Spinal%20Tether&rft.jtitle=Spine%20deformity&rft.au=Bogie,%20R.,%20MD&rft.date=2017&rft.volume=5&rft.issue=1&rft.spage=2&rft.epage=10&rft.pages=2-10&rft.issn=2212-134X&rft.eissn=2212-1358&rft_id=info:doi/10.1016/j.jspd.2016.09.002&rft_dat=%3Cproquest_cross%3E1854616354%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c4142-8224feade58f5e8aa7f49cd465cc461fa116859268ff2954ff0f9e642b915ea83%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1854616354&rft_id=info:pmid/28038690&rfr_iscdi=true