Loading…

Comprehensive Two-Dimensional Gas Chromatography and Chemometrics for the High-Speed Quantitative Analysis of Aromatic Isomers in a Jet Fuel Using the Standard Addition Method and an Objective Retention Time Alignment Algorithm

A high-speed quantitative analysis of aromatic isomers in a jet fuel sample is performed using comprehensive two-dimensional gas chromatography (GC × GC) and chemometrics. A GC × GC separation time of 2.8 min is achieved for three aromatic isomers in jet fuel, which is 5 times faster than a referenc...

Full description

Saved in:
Bibliographic Details
Published in:Analytical chemistry (Washington) 2000-09, Vol.72 (17), p.4154-4162
Main Authors: Fraga, Carlos G, Prazen, Bryan J, Synovec, Robert E
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-a380t-6970e018f862a6a70a033aa94547558e34af5e20f549a1a13f922c06b158d2393
cites cdi_FETCH-LOGICAL-a380t-6970e018f862a6a70a033aa94547558e34af5e20f549a1a13f922c06b158d2393
container_end_page 4162
container_issue 17
container_start_page 4154
container_title Analytical chemistry (Washington)
container_volume 72
creator Fraga, Carlos G
Prazen, Bryan J
Synovec, Robert E
description A high-speed quantitative analysis of aromatic isomers in a jet fuel sample is performed using comprehensive two-dimensional gas chromatography (GC × GC) and chemometrics. A GC × GC separation time of 2.8 min is achieved for three aromatic isomers in jet fuel, which is 5 times faster than a reference method in which a single-column separation resolves two of the three isomers of interest. The high-speed GC × GC separation is more than 10 times faster than a recent GC × GC separation that fully resolves the three components of interest in gasoline. The high-speed GC × GC analysis of jet fuel is accomplished through short GC columns, high gas velocities, and partial chromatographic peak resolution followed by chemometric resolution of overlapped peaks. The standard addition method and an objective retention time alignment algorithm are used to correct for retention time variations prior to the chemometric data analysis. The standard addition method corrects for chemical matrix effects that cause analytes in complex samples to have peak shapes, widths, and retention times that differ considerably from those of calibration standards in pure solvents. The retention time alignment algorithm corrects for the relatively small retention time variations caused by fluctuating instrumental parameters such as flow rate and temperature. The use of data point interpolation in the retention time alignment algorithm results in a more accurate retention time correction then previously achieved. The generalized rank annihilation method (GRAM) is the chemometric technique used to resolve the overlapped GC × GC peaks. The correction of retention time variations allows for successful GRAM signal deconvolution. Using the retention time alignment algorithm, GRAM quantification accuracy and precision are improved by a factor of 4. The methodology used in this paper should be applicable to other comprehensive separation methods, such as two-dimensional liquid chromatography, liquid chromatography coupled with capillary electrophoresis, and liquid chromatography coupled with gas chromatography.
doi_str_mv 10.1021/ac000303b
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1859332415</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1859332415</sourcerecordid><originalsourceid>FETCH-LOGICAL-a380t-6970e018f862a6a70a033aa94547558e34af5e20f549a1a13f922c06b158d2393</originalsourceid><addsrcrecordid>eNptkcty0zAUhj0MDA2FBS_AaEFnYGHQxfJlmQkkbSdMKUnZek7s41jBloIk0-Z5eRGUyxQWrCQdffrO0fxR9JrRD4xy9hEqSqmgYvUkGjHJaZzmOX8ajfbVmGeUnkUvnNtQyhhl6fPojNGiSIosH0W_J6bfWmxRO_ULyfLexJ9Uvz8ZDR2ZgSOT1poevFlb2LY7AroOJexNj96qypHGWOJbJJdq3caLLWJNbgfQXnnwe-c4iHZOOWIaMj6oVEWuXHhvHVGaALlGT6YDduTOKb0-yBY-9AFbk3FdKx-GIV_Qt6Y-tAdNblYbrA76b-hRH4hlGJyMO7XW4QM-7NbGKt_2L6NnDXQOX53W8-hu-nk5uYznN7OryXgeg8ipj9Mio0hZ3uQphxQyClQIgCKRSSZljiKBRiKnjUwKYMBEU3Be0XTFZF5zUYjz6N3Ru7Xm54DOl71yFXYdaDSDK1kuCyF4wmRA3x_RyhrnLDbl1qoe7K5ktNxnWj5mGtg3J-2w6rH-hzyGGIC3JwBcBV1jQVfK_eUkk5LzgMVHTDmPD4_XYH-UaSYyWS6_LsrvGbudXs_mJQv8xZGHypUbM9iQo_vPfH8AYbHGog</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1859332415</pqid></control><display><type>article</type><title>Comprehensive Two-Dimensional Gas Chromatography and Chemometrics for the High-Speed Quantitative Analysis of Aromatic Isomers in a Jet Fuel Using the Standard Addition Method and an Objective Retention Time Alignment Algorithm</title><source>American Chemical Society:Jisc Collections:American Chemical Society Read &amp; Publish Agreement 2022-2024 (Reading list)</source><creator>Fraga, Carlos G ; Prazen, Bryan J ; Synovec, Robert E</creator><creatorcontrib>Fraga, Carlos G ; Prazen, Bryan J ; Synovec, Robert E</creatorcontrib><description>A high-speed quantitative analysis of aromatic isomers in a jet fuel sample is performed using comprehensive two-dimensional gas chromatography (GC × GC) and chemometrics. A GC × GC separation time of 2.8 min is achieved for three aromatic isomers in jet fuel, which is 5 times faster than a reference method in which a single-column separation resolves two of the three isomers of interest. The high-speed GC × GC separation is more than 10 times faster than a recent GC × GC separation that fully resolves the three components of interest in gasoline. The high-speed GC × GC analysis of jet fuel is accomplished through short GC columns, high gas velocities, and partial chromatographic peak resolution followed by chemometric resolution of overlapped peaks. The standard addition method and an objective retention time alignment algorithm are used to correct for retention time variations prior to the chemometric data analysis. The standard addition method corrects for chemical matrix effects that cause analytes in complex samples to have peak shapes, widths, and retention times that differ considerably from those of calibration standards in pure solvents. The retention time alignment algorithm corrects for the relatively small retention time variations caused by fluctuating instrumental parameters such as flow rate and temperature. The use of data point interpolation in the retention time alignment algorithm results in a more accurate retention time correction then previously achieved. The generalized rank annihilation method (GRAM) is the chemometric technique used to resolve the overlapped GC × GC peaks. The correction of retention time variations allows for successful GRAM signal deconvolution. Using the retention time alignment algorithm, GRAM quantification accuracy and precision are improved by a factor of 4. The methodology used in this paper should be applicable to other comprehensive separation methods, such as two-dimensional liquid chromatography, liquid chromatography coupled with capillary electrophoresis, and liquid chromatography coupled with gas chromatography.</description><identifier>ISSN: 0003-2700</identifier><identifier>EISSN: 1520-6882</identifier><identifier>DOI: 10.1021/ac000303b</identifier><identifier>PMID: 10994978</identifier><identifier>CODEN: ANCHAM</identifier><language>eng</language><publisher>Washington, DC: American Chemical Society</publisher><subject>Analytical chemistry ; Applied sciences ; Chemistry ; Chromatographic methods and physical methods associated with chromatography ; Crude oil, natural gas and petroleum products ; Energy ; Exact sciences and technology ; Fuels ; Gas chromatographic methods ; Petroleum products, gas and fuels. Motor fuels, lubricants and asphalts</subject><ispartof>Analytical chemistry (Washington), 2000-09, Vol.72 (17), p.4154-4162</ispartof><rights>Copyright © 2000 American Chemical Society</rights><rights>2000 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a380t-6970e018f862a6a70a033aa94547558e34af5e20f549a1a13f922c06b158d2393</citedby><cites>FETCH-LOGICAL-a380t-6970e018f862a6a70a033aa94547558e34af5e20f549a1a13f922c06b158d2393</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=1515522$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/10994978$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Fraga, Carlos G</creatorcontrib><creatorcontrib>Prazen, Bryan J</creatorcontrib><creatorcontrib>Synovec, Robert E</creatorcontrib><title>Comprehensive Two-Dimensional Gas Chromatography and Chemometrics for the High-Speed Quantitative Analysis of Aromatic Isomers in a Jet Fuel Using the Standard Addition Method and an Objective Retention Time Alignment Algorithm</title><title>Analytical chemistry (Washington)</title><addtitle>Anal. Chem</addtitle><description>A high-speed quantitative analysis of aromatic isomers in a jet fuel sample is performed using comprehensive two-dimensional gas chromatography (GC × GC) and chemometrics. A GC × GC separation time of 2.8 min is achieved for three aromatic isomers in jet fuel, which is 5 times faster than a reference method in which a single-column separation resolves two of the three isomers of interest. The high-speed GC × GC separation is more than 10 times faster than a recent GC × GC separation that fully resolves the three components of interest in gasoline. The high-speed GC × GC analysis of jet fuel is accomplished through short GC columns, high gas velocities, and partial chromatographic peak resolution followed by chemometric resolution of overlapped peaks. The standard addition method and an objective retention time alignment algorithm are used to correct for retention time variations prior to the chemometric data analysis. The standard addition method corrects for chemical matrix effects that cause analytes in complex samples to have peak shapes, widths, and retention times that differ considerably from those of calibration standards in pure solvents. The retention time alignment algorithm corrects for the relatively small retention time variations caused by fluctuating instrumental parameters such as flow rate and temperature. The use of data point interpolation in the retention time alignment algorithm results in a more accurate retention time correction then previously achieved. The generalized rank annihilation method (GRAM) is the chemometric technique used to resolve the overlapped GC × GC peaks. The correction of retention time variations allows for successful GRAM signal deconvolution. Using the retention time alignment algorithm, GRAM quantification accuracy and precision are improved by a factor of 4. The methodology used in this paper should be applicable to other comprehensive separation methods, such as two-dimensional liquid chromatography, liquid chromatography coupled with capillary electrophoresis, and liquid chromatography coupled with gas chromatography.</description><subject>Analytical chemistry</subject><subject>Applied sciences</subject><subject>Chemistry</subject><subject>Chromatographic methods and physical methods associated with chromatography</subject><subject>Crude oil, natural gas and petroleum products</subject><subject>Energy</subject><subject>Exact sciences and technology</subject><subject>Fuels</subject><subject>Gas chromatographic methods</subject><subject>Petroleum products, gas and fuels. Motor fuels, lubricants and asphalts</subject><issn>0003-2700</issn><issn>1520-6882</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2000</creationdate><recordtype>article</recordtype><recordid>eNptkcty0zAUhj0MDA2FBS_AaEFnYGHQxfJlmQkkbSdMKUnZek7s41jBloIk0-Z5eRGUyxQWrCQdffrO0fxR9JrRD4xy9hEqSqmgYvUkGjHJaZzmOX8ajfbVmGeUnkUvnNtQyhhl6fPojNGiSIosH0W_J6bfWmxRO_ULyfLexJ9Uvz8ZDR2ZgSOT1poevFlb2LY7AroOJexNj96qypHGWOJbJJdq3caLLWJNbgfQXnnwe-c4iHZOOWIaMj6oVEWuXHhvHVGaALlGT6YDduTOKb0-yBY-9AFbk3FdKx-GIV_Qt6Y-tAdNblYbrA76b-hRH4hlGJyMO7XW4QM-7NbGKt_2L6NnDXQOX53W8-hu-nk5uYznN7OryXgeg8ipj9Mio0hZ3uQphxQyClQIgCKRSSZljiKBRiKnjUwKYMBEU3Be0XTFZF5zUYjz6N3Ru7Xm54DOl71yFXYdaDSDK1kuCyF4wmRA3x_RyhrnLDbl1qoe7K5ktNxnWj5mGtg3J-2w6rH-hzyGGIC3JwBcBV1jQVfK_eUkk5LzgMVHTDmPD4_XYH-UaSYyWS6_LsrvGbudXs_mJQv8xZGHypUbM9iQo_vPfH8AYbHGog</recordid><startdate>20000901</startdate><enddate>20000901</enddate><creator>Fraga, Carlos G</creator><creator>Prazen, Bryan J</creator><creator>Synovec, Robert E</creator><general>American Chemical Society</general><scope>BSCLL</scope><scope>IQODW</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20000901</creationdate><title>Comprehensive Two-Dimensional Gas Chromatography and Chemometrics for the High-Speed Quantitative Analysis of Aromatic Isomers in a Jet Fuel Using the Standard Addition Method and an Objective Retention Time Alignment Algorithm</title><author>Fraga, Carlos G ; Prazen, Bryan J ; Synovec, Robert E</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a380t-6970e018f862a6a70a033aa94547558e34af5e20f549a1a13f922c06b158d2393</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2000</creationdate><topic>Analytical chemistry</topic><topic>Applied sciences</topic><topic>Chemistry</topic><topic>Chromatographic methods and physical methods associated with chromatography</topic><topic>Crude oil, natural gas and petroleum products</topic><topic>Energy</topic><topic>Exact sciences and technology</topic><topic>Fuels</topic><topic>Gas chromatographic methods</topic><topic>Petroleum products, gas and fuels. Motor fuels, lubricants and asphalts</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Fraga, Carlos G</creatorcontrib><creatorcontrib>Prazen, Bryan J</creatorcontrib><creatorcontrib>Synovec, Robert E</creatorcontrib><collection>Istex</collection><collection>Pascal-Francis</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Analytical chemistry (Washington)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Fraga, Carlos G</au><au>Prazen, Bryan J</au><au>Synovec, Robert E</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comprehensive Two-Dimensional Gas Chromatography and Chemometrics for the High-Speed Quantitative Analysis of Aromatic Isomers in a Jet Fuel Using the Standard Addition Method and an Objective Retention Time Alignment Algorithm</atitle><jtitle>Analytical chemistry (Washington)</jtitle><addtitle>Anal. Chem</addtitle><date>2000-09-01</date><risdate>2000</risdate><volume>72</volume><issue>17</issue><spage>4154</spage><epage>4162</epage><pages>4154-4162</pages><issn>0003-2700</issn><eissn>1520-6882</eissn><coden>ANCHAM</coden><abstract>A high-speed quantitative analysis of aromatic isomers in a jet fuel sample is performed using comprehensive two-dimensional gas chromatography (GC × GC) and chemometrics. A GC × GC separation time of 2.8 min is achieved for three aromatic isomers in jet fuel, which is 5 times faster than a reference method in which a single-column separation resolves two of the three isomers of interest. The high-speed GC × GC separation is more than 10 times faster than a recent GC × GC separation that fully resolves the three components of interest in gasoline. The high-speed GC × GC analysis of jet fuel is accomplished through short GC columns, high gas velocities, and partial chromatographic peak resolution followed by chemometric resolution of overlapped peaks. The standard addition method and an objective retention time alignment algorithm are used to correct for retention time variations prior to the chemometric data analysis. The standard addition method corrects for chemical matrix effects that cause analytes in complex samples to have peak shapes, widths, and retention times that differ considerably from those of calibration standards in pure solvents. The retention time alignment algorithm corrects for the relatively small retention time variations caused by fluctuating instrumental parameters such as flow rate and temperature. The use of data point interpolation in the retention time alignment algorithm results in a more accurate retention time correction then previously achieved. The generalized rank annihilation method (GRAM) is the chemometric technique used to resolve the overlapped GC × GC peaks. The correction of retention time variations allows for successful GRAM signal deconvolution. Using the retention time alignment algorithm, GRAM quantification accuracy and precision are improved by a factor of 4. The methodology used in this paper should be applicable to other comprehensive separation methods, such as two-dimensional liquid chromatography, liquid chromatography coupled with capillary electrophoresis, and liquid chromatography coupled with gas chromatography.</abstract><cop>Washington, DC</cop><pub>American Chemical Society</pub><pmid>10994978</pmid><doi>10.1021/ac000303b</doi><tpages>9</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0003-2700
ispartof Analytical chemistry (Washington), 2000-09, Vol.72 (17), p.4154-4162
issn 0003-2700
1520-6882
language eng
recordid cdi_proquest_miscellaneous_1859332415
source American Chemical Society:Jisc Collections:American Chemical Society Read & Publish Agreement 2022-2024 (Reading list)
subjects Analytical chemistry
Applied sciences
Chemistry
Chromatographic methods and physical methods associated with chromatography
Crude oil, natural gas and petroleum products
Energy
Exact sciences and technology
Fuels
Gas chromatographic methods
Petroleum products, gas and fuels. Motor fuels, lubricants and asphalts
title Comprehensive Two-Dimensional Gas Chromatography and Chemometrics for the High-Speed Quantitative Analysis of Aromatic Isomers in a Jet Fuel Using the Standard Addition Method and an Objective Retention Time Alignment Algorithm
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T17%3A06%3A35IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comprehensive%20Two-Dimensional%20Gas%20Chromatography%20and%20Chemometrics%20for%20the%20High-Speed%20Quantitative%20Analysis%20of%20Aromatic%20Isomers%20in%20a%20Jet%20Fuel%20Using%20the%20Standard%20Addition%20Method%20and%20an%20Objective%20Retention%20Time%20Alignment%20Algorithm&rft.jtitle=Analytical%20chemistry%20(Washington)&rft.au=Fraga,%20Carlos%20G&rft.date=2000-09-01&rft.volume=72&rft.issue=17&rft.spage=4154&rft.epage=4162&rft.pages=4154-4162&rft.issn=0003-2700&rft.eissn=1520-6882&rft.coden=ANCHAM&rft_id=info:doi/10.1021/ac000303b&rft_dat=%3Cproquest_cross%3E1859332415%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-a380t-6970e018f862a6a70a033aa94547558e34af5e20f549a1a13f922c06b158d2393%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1859332415&rft_id=info:pmid/10994978&rfr_iscdi=true