Loading…

Accuracy of hysterosalpingo-foam sonography in comparison to hysterosalpingo-contrast sonography with air/saline and to laparoscopy with dye

Abstract STUDY QUESTION What is the diagnostic accuracy of 2D/3D hysterosalpingo-foam sonography (HyFoSy) and 2D/3D-high-definition flow Doppler (HDF)-HyFoSy in comparison to laparoscopy with dye chromotubation (as the reference method) and 2D air/saline-enhanced hysterosalpingo-contrast sonography...

Full description

Saved in:
Bibliographic Details
Published in:Human reproduction (Oxford) 2017-04, Vol.32 (4), p.758-769
Main Authors: Ludwin, I., Ludwin, A., Wiechec, M., Nocun, A., Banas, T., Basta, P., Pitynski, K.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Abstract STUDY QUESTION What is the diagnostic accuracy of 2D/3D hysterosalpingo-foam sonography (HyFoSy) and 2D/3D-high-definition flow Doppler (HDF)-HyFoSy in comparison to laparoscopy with dye chromotubation (as the reference method) and 2D air/saline-enhanced hysterosalpingo-contrast sonography (HyCoSy) (as the initial index test)? SUMMARY ANSWER 2D/3D-HDF-HyFoSy had the best diagnostic accuracy and was the only method that did not significantly differ from the reference method, while both 2D/3D-HyFoSy and 2D/3D-HDF-HyFoSy had significantly higher accuracy than 2D-air/saline-HyCoSy. WHAT IS KNOWN ALREADY Previous studies on X-ray hysterosalpingography and laparoscopy and dye as the reference standard have undermined the impact of older commercial contrast agents on the accuracy of ultrasound tubal patency tests. Recently, HyFoSy was reported to have very high accuracy in a small pilot study in comparison to laparoscopy and dye, and had a very high positive predictive value (PPV) for medical tubal occlusion. A new Doppler sonographic technique, known as HDF imaging with better axial resolution, fewer blooming artifacts and higher sensitivity than color and power Doppler imaging, has been introduced. STUDY DESIGN, SIZE, DURATION A prospective observational study was performed on 132 women (259 Fallopian tubes) consecutively enrolled between 2013 and 2015. PARTICIPANTS/MATERIALS, SETTING, METHODS This study included infertile women of reproductive age who previously had not been examined for tubal patency and who presented for the evaluation to the university hospital, private hospital and clinic at which this study was conducted. 2D-Air/saline-HyCoSy, 2D/3D-HyFoSy and 2D/3D-HDF-HyFoSy and laparoscopy were performed independently by experienced readers. During HyFoSy, the 3D mode was used for standardization of pelvic scanning and observations of contrast flow without diagnosis after volume acquisition. Sensitivity, specificity, negative and positive predictive value (NPV and PPV), negative and positive-likelihood ratio (LR− and LR+) and 95% CI were calculated. McNemar's test and relative predictive values (a comparison of NPV and PPV) were used to compare all the index tests. MAIN RESULTS AND THE ROLE OF CHANCE 2D-Air/saline-HyCoSy, 2D/3D-HyFoSy and 2D/3D-HDF-HyFoSy indicated that 46 (17.8%), 27 (10.4%) and 24 (9.2%) of the 259 tubes were occluded, respectively; additionally, inconclusive results were obtained for 8 (3%), 5 (1.9%) and 3 (1.2%) tubes, res
ISSN:0268-1161
1460-2350
DOI:10.1093/humrep/dex013