Percutaneous Plug-Based Arteriotomy Closure Device for Large-Bore Access: A Multicenter Prospective Study

The authors sought to study the safety and efficacy of the MANTA Vascular Closure Device (VCD), a novel collagen-based technology dedicated to closure of large-bore arteriotomies. Novel transfemoral therapeutic interventions requiring large-bore catheters have become valid minimally invasive options...

Full description

Saved in:
Bibliographic Details
Published in:JACC. Cardiovascular interventions 2017-03, Vol.10 (6), p.613-619
Main Authors: Van Mieghem, Nicolas M, Latib, Azeem, van der Heyden, Jan, van Gils, Lennart, Daemen, Joost, Sorzano, Todd, Ligthart, Jurgen, Witberg, Karin, de Kroon, Thom, Maor, Nathaniel, Mangieri, Antonio, Montorfano, Matteo, de Jaegere, Peter P, Colombo, Antonio, Roubin, Gary
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The authors sought to study the safety and efficacy of the MANTA Vascular Closure Device (VCD), a novel collagen-based technology dedicated to closure of large-bore arteriotomies. Novel transfemoral therapeutic interventions requiring large-bore catheters have become valid minimally invasive options but have inherent access management challenges. To date, no dedicated vascular closure devices exist for large arteriotomies. A prospective, single-arm clinical investigation enrolling patients who underwent elective percutaneous interventions with large-bore catheters and planned percutaneous arteriotomy closure in 3 European institutions. A total of 50 patients with a mean age of 79.5 ± 8.3 years underwent high-risk percutaneous coronary intervention, balloon aortic valvuloplasty, or transcatheter aortic valve replacement with large-bore catheters sized 12-F to 19-F. MANTA closure was performed by 9 different operators. The 14-F MANTA VCD was deployed in one-third of the overall cohort (16 of 50, 32%), and the 18-F MANTA VCD in the remainder. The MANTA VCD was deployed successfully in all patients. The mean time to hemostasis was 2 min, 23 s. One patient had a major vascular and major bleeding complication with prolonged femoral bleeding that was successfully treated with a covered stent and eventual surgical repair. There were no other access site-related complications. This first multicenter experience demonstrates rapid and reliable hemostasis and low complication rates with the use of the plug-based MANTA VCD for large-bore arteriotomy closure.
ISSN:1876-7605
DOI:10.1016/j.jcin.2016.12.277