Loading…

Source localization of ictal epileptic activity based on high‐density scalp EEG data

Summary Objective Electrical source imaging (ESI) is a well‐established approach to localizing the epileptic focus in drug‐resistant focal epilepsy. So far, ESI has been used primarily on interictal events. Emerging evidence suggests that ictal ESI is also feasible and potentially useful. We aimed t...

Full description

Saved in:
Bibliographic Details
Published in:Epilepsia (Copenhagen) 2017-06, Vol.58 (6), p.1027-1036
Main Authors: Nemtsas, Petros, Birot, Gwenael, Pittau, Francesca, Michel, Christoph M., Schaller, Karl, Vulliemoz, Serge, Kimiskidis, Vasilios K., Seeck, Margitta
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Summary Objective Electrical source imaging (ESI) is a well‐established approach to localizing the epileptic focus in drug‐resistant focal epilepsy. So far, ESI has been used primarily on interictal events. Emerging evidence suggests that ictal ESI is also feasible and potentially useful. We aimed to investigate the diagnostic accuracy of ESI on ictal events using high‐density electroencephalography (EEG). Methods We performed ictal ESI on 14 patients (9 with temporal lobe epilepsy) admitted for presurgical evaluation who presented seizures during a long‐term (≥18 h) high‐density EEG recording (13 with 256 electrodes and one with 128 electrodes), and subsequently 8 of them underwent epilepsy surgery (postoperative follow‐up >1 year). Artifact‐free EEG epochs at ictal οnset were selected for further analysis. The predominant ictal rhythm was identified and filtered (±1 Hz around the main frequency). ESI was computed for each time point using an individual head model and a distributed linear inverse solution, and the average across source localizations was localized. For validation, results were compared with the resection area and postoperative outcome. Results Ictal ESI correctly localized the epileptic seizure‐onset zone in the resection area in five of six postoperatively seizure‐free patients. Interictal and ictal ESI were concordant in 9 of 14 patients and partially concordant in additional 4 of 14 patients (93%). Divergent solutions were found in only one of the 14 patients (7%). Significance Ictal ESI is a promising localization technique in focal epilepsy.
ISSN:0013-9580
1528-1167
DOI:10.1111/epi.13749