Determination of the Heat-Exchange Characteristics of Low-Pressure Heat-Exchangers for Lead and Lead-Bismuth Cooled Loops
Heat removal during transient processes in nuclear power installations and bench loops cooled by lead and lead-bismuth coolant is studied. It is shown that low-pressure heat-exchange equipment is effective. The studies were conducted in a non-isothermal loop with circulating of lead coolant at 450–5...
Saved in:
Published in: | Atomic energy (New York, N.Y.) N.Y.), 2017-03, Vol.121 (5), p.334-338 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Heat removal during transient processes in nuclear power installations and bench loops cooled by lead and lead-bismuth coolant is studied. It is shown that low-pressure heat-exchange equipment is effective. The studies were conducted in a non-isothermal loop with circulating of lead coolant at 450–500°C, average speed in the narrow section of the gap in longitudinal flow over the heat-exchange surface 0.1–1.05 m/sec, Peclet number 300–3300, and the oxygen thermodynamic activity in lead 1–10
–3
. The processes occurring in a non-isothermal liquid-metal loop with an experimental heat-exchange section model the dependence of the heat-exchange characteristics on impurity mass transfer in the loop. |
---|---|
ISSN: | 1063-4258 1573-8205 |
DOI: | 10.1007/s10512-017-0207-2 |