Test-Retest Reliability of the Dual-Microphone Voice Range Profile

The voice range profile (VRP) measures vocal intensity and fundamental frequency. Phonosurgical and logopedic treatment outcome studies using the VRP report voice improvements of 3–6 semitones (ST) in ST range and 4–7 decibels (dB) in sound pressure level range after treatment. These small improveme...

Full description

Saved in:
Bibliographic Details
Published in:Journal of voice 2018-01, Vol.32 (1), p.32-37
Main Authors: Printz, Trine, Sorensen, Jesper Roed, Godballe, Christian, Grøntved, Ågot Møller
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c408t-420dda7d01c0638d64d649127b7f71091607436310609f8be6b3e2c1b0ae7e23
cites cdi_FETCH-LOGICAL-c408t-420dda7d01c0638d64d649127b7f71091607436310609f8be6b3e2c1b0ae7e23
container_end_page 37
container_issue 1
container_start_page 32
container_title Journal of voice
container_volume 32
creator Printz, Trine
Sorensen, Jesper Roed
Godballe, Christian
Grøntved, Ågot Møller
description The voice range profile (VRP) measures vocal intensity and fundamental frequency. Phonosurgical and logopedic treatment outcome studies using the VRP report voice improvements of 3–6 semitones (ST) in ST range and 4–7 decibels (dB) in sound pressure level range after treatment. These small improvements stress the importance of reliable measurements. The aim was to evaluate the test-retest reliability of the dual-microphone computerized VRP on participants with healthy voices. This is a prospective test-retest reliability study. Dual-microphone VRPs were repeated twice on healthy participants (n = 37) with an interval of 6–37 days. Voice frequency and intensity (minimum, maximum, and ranges) were assessed in combination with the area of the VRP. Correlations between VRP parameters were high (r > 0.60). However, in the retest, a statistically significant increase in voice frequency range (1.4 ST [95% confidence interval {CI}: 0.8–2.1 ST], P 
doi_str_mv 10.1016/j.jvoice.2017.03.019
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1900831417</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S089219971630515X</els_id><sourcerecordid>1900831417</sourcerecordid><originalsourceid>FETCH-LOGICAL-c408t-420dda7d01c0638d64d649127b7f71091607436310609f8be6b3e2c1b0ae7e23</originalsourceid><addsrcrecordid>eNp9kE9Lw0AQxRdRbK1-A5EcvSTO7KbZ3Yug9S9UlFK8LslmYrekTc2mhX57t7R6FAbmMG_mvfkxdomQIGB2M0_mm8ZZSjigTEAkgPqI9VFJEadDpY5ZH5TmMWote-zM-zkA8DA9ZT2uhjxLh7rP7qfku3hCXWjRhGqXF6523TZqqqibUfSwzuv4zdm2Wc2aJUWfO8toki-_KPpom8rVdM5Oqrz2dHHoAzZ9epyOXuLx-_Pr6G4c2xRUF6ccyjKXJaCFTKgyS0Np5LKQlUTQmIFMRSYQMtCVKigrBHGLBeQkiYsBu96fXbXN9zrENQvnLdV1vqRm7Q1qACUwRRmk6V4aYnvfUmVWrVvk7dYgmB08Mzd7eGYHz4AwAV5Yuzo4rIsFlX9Lv7SC4HYvoPDmxlFrvHW0tFS6lmxnysb97_ADz0mATw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1900831417</pqid></control><display><type>article</type><title>Test-Retest Reliability of the Dual-Microphone Voice Range Profile</title><source>ScienceDirect Freedom Collection</source><creator>Printz, Trine ; Sorensen, Jesper Roed ; Godballe, Christian ; Grøntved, Ågot Møller</creator><creatorcontrib>Printz, Trine ; Sorensen, Jesper Roed ; Godballe, Christian ; Grøntved, Ågot Møller</creatorcontrib><description>The voice range profile (VRP) measures vocal intensity and fundamental frequency. Phonosurgical and logopedic treatment outcome studies using the VRP report voice improvements of 3–6 semitones (ST) in ST range and 4–7 decibels (dB) in sound pressure level range after treatment. These small improvements stress the importance of reliable measurements. The aim was to evaluate the test-retest reliability of the dual-microphone computerized VRP on participants with healthy voices. This is a prospective test-retest reliability study. Dual-microphone VRPs were repeated twice on healthy participants (n = 37) with an interval of 6–37 days. Voice frequency and intensity (minimum, maximum, and ranges) were assessed in combination with the area of the VRP. Correlations between VRP parameters were high (r &gt; 0.60). However, in the retest, a statistically significant increase in voice frequency range (1.4 ST [95% confidence interval {CI}: 0.8–2.1 ST], P &lt; 0.001), intensity ranges (2.2 dB [95% CI: 1.0–3.4 dB], P &lt; 0.001), maximum frequency (1.0 ST [95% CI: 0.5–1.6 ST], P &lt; 0.001), maximum intensity (1.4 dB [95% CI: 0.5–2.3 dB], P = 0.002), and area inside the VRP (148 cells [95% CI: 87–210 cells], P &lt; 0.001) was observed. The intra-examiner variation of the dual-microphone VRP is well below the differences seen after surgical or logopedic intervention, even when measuring in non-sound-treated rooms. There is a need for studies regarding inter-examiner reliability with a longer interval between test and retest before the assessment is fully reliable for clinical application.</description><identifier>ISSN: 0892-1997</identifier><identifier>EISSN: 1873-4588</identifier><identifier>DOI: 10.1016/j.jvoice.2017.03.019</identifier><identifier>PMID: 28526459</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Phonetogram ; Test-retest reliability ; Voice assessment ; Voice evaluation ; Voice range profile</subject><ispartof>Journal of voice, 2018-01, Vol.32 (1), p.32-37</ispartof><rights>2018 The Authors</rights><rights>Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c408t-420dda7d01c0638d64d649127b7f71091607436310609f8be6b3e2c1b0ae7e23</citedby><cites>FETCH-LOGICAL-c408t-420dda7d01c0638d64d649127b7f71091607436310609f8be6b3e2c1b0ae7e23</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/28526459$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Printz, Trine</creatorcontrib><creatorcontrib>Sorensen, Jesper Roed</creatorcontrib><creatorcontrib>Godballe, Christian</creatorcontrib><creatorcontrib>Grøntved, Ågot Møller</creatorcontrib><title>Test-Retest Reliability of the Dual-Microphone Voice Range Profile</title><title>Journal of voice</title><addtitle>J Voice</addtitle><description>The voice range profile (VRP) measures vocal intensity and fundamental frequency. Phonosurgical and logopedic treatment outcome studies using the VRP report voice improvements of 3–6 semitones (ST) in ST range and 4–7 decibels (dB) in sound pressure level range after treatment. These small improvements stress the importance of reliable measurements. The aim was to evaluate the test-retest reliability of the dual-microphone computerized VRP on participants with healthy voices. This is a prospective test-retest reliability study. Dual-microphone VRPs were repeated twice on healthy participants (n = 37) with an interval of 6–37 days. Voice frequency and intensity (minimum, maximum, and ranges) were assessed in combination with the area of the VRP. Correlations between VRP parameters were high (r &gt; 0.60). However, in the retest, a statistically significant increase in voice frequency range (1.4 ST [95% confidence interval {CI}: 0.8–2.1 ST], P &lt; 0.001), intensity ranges (2.2 dB [95% CI: 1.0–3.4 dB], P &lt; 0.001), maximum frequency (1.0 ST [95% CI: 0.5–1.6 ST], P &lt; 0.001), maximum intensity (1.4 dB [95% CI: 0.5–2.3 dB], P = 0.002), and area inside the VRP (148 cells [95% CI: 87–210 cells], P &lt; 0.001) was observed. The intra-examiner variation of the dual-microphone VRP is well below the differences seen after surgical or logopedic intervention, even when measuring in non-sound-treated rooms. There is a need for studies regarding inter-examiner reliability with a longer interval between test and retest before the assessment is fully reliable for clinical application.</description><subject>Phonetogram</subject><subject>Test-retest reliability</subject><subject>Voice assessment</subject><subject>Voice evaluation</subject><subject>Voice range profile</subject><issn>0892-1997</issn><issn>1873-4588</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNp9kE9Lw0AQxRdRbK1-A5EcvSTO7KbZ3Yug9S9UlFK8LslmYrekTc2mhX57t7R6FAbmMG_mvfkxdomQIGB2M0_mm8ZZSjigTEAkgPqI9VFJEadDpY5ZH5TmMWote-zM-zkA8DA9ZT2uhjxLh7rP7qfku3hCXWjRhGqXF6523TZqqqibUfSwzuv4zdm2Wc2aJUWfO8toki-_KPpom8rVdM5Oqrz2dHHoAzZ9epyOXuLx-_Pr6G4c2xRUF6ccyjKXJaCFTKgyS0Np5LKQlUTQmIFMRSYQMtCVKigrBHGLBeQkiYsBu96fXbXN9zrENQvnLdV1vqRm7Q1qACUwRRmk6V4aYnvfUmVWrVvk7dYgmB08Mzd7eGYHz4AwAV5Yuzo4rIsFlX9Lv7SC4HYvoPDmxlFrvHW0tFS6lmxnysb97_ADz0mATw</recordid><startdate>201801</startdate><enddate>201801</enddate><creator>Printz, Trine</creator><creator>Sorensen, Jesper Roed</creator><creator>Godballe, Christian</creator><creator>Grøntved, Ågot Møller</creator><general>Elsevier Inc</general><scope>6I.</scope><scope>AAFTH</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201801</creationdate><title>Test-Retest Reliability of the Dual-Microphone Voice Range Profile</title><author>Printz, Trine ; Sorensen, Jesper Roed ; Godballe, Christian ; Grøntved, Ågot Møller</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c408t-420dda7d01c0638d64d649127b7f71091607436310609f8be6b3e2c1b0ae7e23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Phonetogram</topic><topic>Test-retest reliability</topic><topic>Voice assessment</topic><topic>Voice evaluation</topic><topic>Voice range profile</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Printz, Trine</creatorcontrib><creatorcontrib>Sorensen, Jesper Roed</creatorcontrib><creatorcontrib>Godballe, Christian</creatorcontrib><creatorcontrib>Grøntved, Ågot Møller</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of voice</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Printz, Trine</au><au>Sorensen, Jesper Roed</au><au>Godballe, Christian</au><au>Grøntved, Ågot Møller</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Test-Retest Reliability of the Dual-Microphone Voice Range Profile</atitle><jtitle>Journal of voice</jtitle><addtitle>J Voice</addtitle><date>2018-01</date><risdate>2018</risdate><volume>32</volume><issue>1</issue><spage>32</spage><epage>37</epage><pages>32-37</pages><issn>0892-1997</issn><eissn>1873-4588</eissn><abstract>The voice range profile (VRP) measures vocal intensity and fundamental frequency. Phonosurgical and logopedic treatment outcome studies using the VRP report voice improvements of 3–6 semitones (ST) in ST range and 4–7 decibels (dB) in sound pressure level range after treatment. These small improvements stress the importance of reliable measurements. The aim was to evaluate the test-retest reliability of the dual-microphone computerized VRP on participants with healthy voices. This is a prospective test-retest reliability study. Dual-microphone VRPs were repeated twice on healthy participants (n = 37) with an interval of 6–37 days. Voice frequency and intensity (minimum, maximum, and ranges) were assessed in combination with the area of the VRP. Correlations between VRP parameters were high (r &gt; 0.60). However, in the retest, a statistically significant increase in voice frequency range (1.4 ST [95% confidence interval {CI}: 0.8–2.1 ST], P &lt; 0.001), intensity ranges (2.2 dB [95% CI: 1.0–3.4 dB], P &lt; 0.001), maximum frequency (1.0 ST [95% CI: 0.5–1.6 ST], P &lt; 0.001), maximum intensity (1.4 dB [95% CI: 0.5–2.3 dB], P = 0.002), and area inside the VRP (148 cells [95% CI: 87–210 cells], P &lt; 0.001) was observed. The intra-examiner variation of the dual-microphone VRP is well below the differences seen after surgical or logopedic intervention, even when measuring in non-sound-treated rooms. There is a need for studies regarding inter-examiner reliability with a longer interval between test and retest before the assessment is fully reliable for clinical application.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>28526459</pmid><doi>10.1016/j.jvoice.2017.03.019</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0892-1997
ispartof Journal of voice, 2018-01, Vol.32 (1), p.32-37
issn 0892-1997
1873-4588
language eng
recordid cdi_proquest_miscellaneous_1900831417
source ScienceDirect Freedom Collection
subjects Phonetogram
Test-retest reliability
Voice assessment
Voice evaluation
Voice range profile
title Test-Retest Reliability of the Dual-Microphone Voice Range Profile
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-09T21%3A11%3A17IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Test-Retest%20Reliability%20of%20the%20Dual-Microphone%20Voice%20Range%20Profile&rft.jtitle=Journal%20of%20voice&rft.au=Printz,%20Trine&rft.date=2018-01&rft.volume=32&rft.issue=1&rft.spage=32&rft.epage=37&rft.pages=32-37&rft.issn=0892-1997&rft.eissn=1873-4588&rft_id=info:doi/10.1016/j.jvoice.2017.03.019&rft_dat=%3Cproquest_cross%3E1900831417%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c408t-420dda7d01c0638d64d649127b7f71091607436310609f8be6b3e2c1b0ae7e23%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1900831417&rft_id=info:pmid/28526459&rfr_iscdi=true