Optimal combination of anti‐scatter grids and software correction for CBCT imaging

Purpose Cone beam computed tomography (CBCT) has been widely adopted in clinical practice for image‐guided radiotherapy. Soft tissue contrast and Hounsfield units are impaired to the presence of scattered radiation. In our previous work, we proposed a high selectivity anti‐scatter grid (ASG) as a po...

Full description

Saved in:
Bibliographic Details
Published in:Medical physics (Lancaster) 2017-09, Vol.44 (9), p.4437-4451
Main Authors: Stankovic, Uros, Ploeger, Lennert S., Herk, Marcel, Sonke, Jan‐Jakob
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c3875-1950122545edc1bd533daad8d1f3c222d8c8d572845d62caf667e34af130d7183
cites cdi_FETCH-LOGICAL-c3875-1950122545edc1bd533daad8d1f3c222d8c8d572845d62caf667e34af130d7183
container_end_page 4451
container_issue 9
container_start_page 4437
container_title Medical physics (Lancaster)
container_volume 44
creator Stankovic, Uros
Ploeger, Lennert S.
Herk, Marcel
Sonke, Jan‐Jakob
description Purpose Cone beam computed tomography (CBCT) has been widely adopted in clinical practice for image‐guided radiotherapy. Soft tissue contrast and Hounsfield units are impaired to the presence of scattered radiation. In our previous work, we proposed a high selectivity anti‐scatter grid (ASG) as a possible solution to the problem. An alternative approach is the application of iterative scatter correction using deconvolution with scatter point spread function (PSF). The purpose of this work was to compare the performance of ASGs with different selectivity with and without the iterative and uniform scatter corrections in terms of CBCT image quality. A secondary objective of this study was to develop a novel measurement approach to measure the scatter point spread functions. Methods The scatter PSF was modeled as a sum of two bivariate Gaussian functions. The PSF parameters were estimated from a series of transmission measurements through polystyrene slabs of varying thickness with lead partial beam‐blocker for three different ASG designs ranging from low (5.6), medium (9), and high (11) selectivity. The scatter correction scheme is based on iterative convolution of the current estimate of the primary with the scatter PSF until the root mean square deviation (RMSD) of the measured projection and the sum of the estimate of primary and scatter falls below a predefined threshold. The image quality was evaluated with the CIRS CBCT Image Quality and Electron Density phantom in a head and neck and pelvis configuration and the CIRS Virtual Male Human Patient. The image quality was quantified by the contrast‐to‐noise ratio (CNR) relative to the uncorrected scans and the root mean square deviation of the average gray values for different regions with respect to the nominal Hounsfield units and the mean difference of the reconstructed HU between the planning CT and CBCTs of the virtual human phantom. Results For the head and neck phantom, the CNR increased with more advanced scatter correction algorithm and the ASG selectivity, reaching 3.9, 3.7, 3.5, and 3.1 for the high, medium, light, and with no grid configuration, respectively, combined with the iterative software correction. The same is true for the pelvis phantom with CNR improvement reaching 1.5 for the heavy and medium grid, 1.3 for the light grid, and 1.1 on its own. The HU RMSD for the head and neck phantom was 22 HU, 13 HU, 12 HU, and 6 HU for iterative correction without the grid, with the light grid, mediu
doi_str_mv 10.1002/mp.12385
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1903944115</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1903944115</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3875-1950122545edc1bd533daad8d1f3c222d8c8d572845d62caf667e34af130d7183</originalsourceid><addsrcrecordid>eNp1kMlKA0EQQBtRTIyCXyBz9DKxepvlqMENIvEQz02nl9AyMz12Twi5-Ql-o1_imEQ9eSooXj2Kh9A5hjEGIFd1O8aEFvwADQnLacoIlIdoCFCylDDgA3QS4ysAZJTDMRqQgvOMABui-aztXC2rRPl64RrZOd8k3iay6dzn-0dUsutMSJbB6dgvdRK97dYymP4gBKO2vPUhmdxM5klvWrpmeYqOrKyiOdvPEXq5u51PHtLp7P5xcj1NFS1ynuKSAyaEM260wgvNKdVS6kJjSxUhRBeq0DwnBeM6I0raLMsNZdJiCjrHBR2hy523Df5tZWInaheVqSrZGL-KApdAS8Yw5n-oCj7GYKxoQ_9t2AgM4ruhqFuxbdijF3vralEb_Qv-ROuBdAesXWU2_4rE0_NO-AVY0Xps</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1903944115</pqid></control><display><type>article</type><title>Optimal combination of anti‐scatter grids and software correction for CBCT imaging</title><source>Wiley</source><creator>Stankovic, Uros ; Ploeger, Lennert S. ; Herk, Marcel ; Sonke, Jan‐Jakob</creator><creatorcontrib>Stankovic, Uros ; Ploeger, Lennert S. ; Herk, Marcel ; Sonke, Jan‐Jakob</creatorcontrib><description>Purpose Cone beam computed tomography (CBCT) has been widely adopted in clinical practice for image‐guided radiotherapy. Soft tissue contrast and Hounsfield units are impaired to the presence of scattered radiation. In our previous work, we proposed a high selectivity anti‐scatter grid (ASG) as a possible solution to the problem. An alternative approach is the application of iterative scatter correction using deconvolution with scatter point spread function (PSF). The purpose of this work was to compare the performance of ASGs with different selectivity with and without the iterative and uniform scatter corrections in terms of CBCT image quality. A secondary objective of this study was to develop a novel measurement approach to measure the scatter point spread functions. Methods The scatter PSF was modeled as a sum of two bivariate Gaussian functions. The PSF parameters were estimated from a series of transmission measurements through polystyrene slabs of varying thickness with lead partial beam‐blocker for three different ASG designs ranging from low (5.6), medium (9), and high (11) selectivity. The scatter correction scheme is based on iterative convolution of the current estimate of the primary with the scatter PSF until the root mean square deviation (RMSD) of the measured projection and the sum of the estimate of primary and scatter falls below a predefined threshold. The image quality was evaluated with the CIRS CBCT Image Quality and Electron Density phantom in a head and neck and pelvis configuration and the CIRS Virtual Male Human Patient. The image quality was quantified by the contrast‐to‐noise ratio (CNR) relative to the uncorrected scans and the root mean square deviation of the average gray values for different regions with respect to the nominal Hounsfield units and the mean difference of the reconstructed HU between the planning CT and CBCTs of the virtual human phantom. Results For the head and neck phantom, the CNR increased with more advanced scatter correction algorithm and the ASG selectivity, reaching 3.9, 3.7, 3.5, and 3.1 for the high, medium, light, and with no grid configuration, respectively, combined with the iterative software correction. The same is true for the pelvis phantom with CNR improvement reaching 1.5 for the heavy and medium grid, 1.3 for the light grid, and 1.1 on its own. The HU RMSD for the head and neck phantom was 22 HU, 13 HU, 12 HU, and 6 HU for iterative correction without the grid, with the light grid, medium grid and the heavy grid, respectively. For same correction strategies, the values for the pelvis phantom where 170, 120, 34, and 27 HU. The average difference with the PCT of the virtual human phantom was 59 ± 48 HU and 63 ± 59 HU with scans reconstructed with the iterative correction and two higher selectivity grids. Visual inspection revealed similar trends for a head‐and‐neck and prostate cancer patient. Conclusions The best scatter mitigation strategy was found to be a combination of a grid with selectivity larger than 9, combined with iterative scatter estimation. None of the investigated grids required increasing the imaging dose. The PSF determined using proposed method leads to image quality improvements results for all but one of the investigated scenarios.</description><identifier>ISSN: 0094-2405</identifier><identifier>EISSN: 2473-4209</identifier><identifier>DOI: 10.1002/mp.12385</identifier><identifier>PMID: 28556204</identifier><language>eng</language><publisher>United States</publisher><subject>CBCT image quality ; Cone-Beam Computed Tomography ; Humans ; image‐guided radiotherapy ; Male ; Phantoms, Imaging ; Radiotherapy, Image-Guided ; Scattering, Radiation ; Software ; User-Computer Interface ; X‐ray scatter</subject><ispartof>Medical physics (Lancaster), 2017-09, Vol.44 (9), p.4437-4451</ispartof><rights>2017 American Association of Physicists in Medicine</rights><rights>2017 American Association of Physicists in Medicine.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3875-1950122545edc1bd533daad8d1f3c222d8c8d572845d62caf667e34af130d7183</citedby><cites>FETCH-LOGICAL-c3875-1950122545edc1bd533daad8d1f3c222d8c8d572845d62caf667e34af130d7183</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/28556204$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Stankovic, Uros</creatorcontrib><creatorcontrib>Ploeger, Lennert S.</creatorcontrib><creatorcontrib>Herk, Marcel</creatorcontrib><creatorcontrib>Sonke, Jan‐Jakob</creatorcontrib><title>Optimal combination of anti‐scatter grids and software correction for CBCT imaging</title><title>Medical physics (Lancaster)</title><addtitle>Med Phys</addtitle><description>Purpose Cone beam computed tomography (CBCT) has been widely adopted in clinical practice for image‐guided radiotherapy. Soft tissue contrast and Hounsfield units are impaired to the presence of scattered radiation. In our previous work, we proposed a high selectivity anti‐scatter grid (ASG) as a possible solution to the problem. An alternative approach is the application of iterative scatter correction using deconvolution with scatter point spread function (PSF). The purpose of this work was to compare the performance of ASGs with different selectivity with and without the iterative and uniform scatter corrections in terms of CBCT image quality. A secondary objective of this study was to develop a novel measurement approach to measure the scatter point spread functions. Methods The scatter PSF was modeled as a sum of two bivariate Gaussian functions. The PSF parameters were estimated from a series of transmission measurements through polystyrene slabs of varying thickness with lead partial beam‐blocker for three different ASG designs ranging from low (5.6), medium (9), and high (11) selectivity. The scatter correction scheme is based on iterative convolution of the current estimate of the primary with the scatter PSF until the root mean square deviation (RMSD) of the measured projection and the sum of the estimate of primary and scatter falls below a predefined threshold. The image quality was evaluated with the CIRS CBCT Image Quality and Electron Density phantom in a head and neck and pelvis configuration and the CIRS Virtual Male Human Patient. The image quality was quantified by the contrast‐to‐noise ratio (CNR) relative to the uncorrected scans and the root mean square deviation of the average gray values for different regions with respect to the nominal Hounsfield units and the mean difference of the reconstructed HU between the planning CT and CBCTs of the virtual human phantom. Results For the head and neck phantom, the CNR increased with more advanced scatter correction algorithm and the ASG selectivity, reaching 3.9, 3.7, 3.5, and 3.1 for the high, medium, light, and with no grid configuration, respectively, combined with the iterative software correction. The same is true for the pelvis phantom with CNR improvement reaching 1.5 for the heavy and medium grid, 1.3 for the light grid, and 1.1 on its own. The HU RMSD for the head and neck phantom was 22 HU, 13 HU, 12 HU, and 6 HU for iterative correction without the grid, with the light grid, medium grid and the heavy grid, respectively. For same correction strategies, the values for the pelvis phantom where 170, 120, 34, and 27 HU. The average difference with the PCT of the virtual human phantom was 59 ± 48 HU and 63 ± 59 HU with scans reconstructed with the iterative correction and two higher selectivity grids. Visual inspection revealed similar trends for a head‐and‐neck and prostate cancer patient. Conclusions The best scatter mitigation strategy was found to be a combination of a grid with selectivity larger than 9, combined with iterative scatter estimation. None of the investigated grids required increasing the imaging dose. The PSF determined using proposed method leads to image quality improvements results for all but one of the investigated scenarios.</description><subject>CBCT image quality</subject><subject>Cone-Beam Computed Tomography</subject><subject>Humans</subject><subject>image‐guided radiotherapy</subject><subject>Male</subject><subject>Phantoms, Imaging</subject><subject>Radiotherapy, Image-Guided</subject><subject>Scattering, Radiation</subject><subject>Software</subject><subject>User-Computer Interface</subject><subject>X‐ray scatter</subject><issn>0094-2405</issn><issn>2473-4209</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNp1kMlKA0EQQBtRTIyCXyBz9DKxepvlqMENIvEQz02nl9AyMz12Twi5-Ql-o1_imEQ9eSooXj2Kh9A5hjEGIFd1O8aEFvwADQnLacoIlIdoCFCylDDgA3QS4ysAZJTDMRqQgvOMABui-aztXC2rRPl64RrZOd8k3iay6dzn-0dUsutMSJbB6dgvdRK97dYymP4gBKO2vPUhmdxM5klvWrpmeYqOrKyiOdvPEXq5u51PHtLp7P5xcj1NFS1ynuKSAyaEM260wgvNKdVS6kJjSxUhRBeq0DwnBeM6I0raLMsNZdJiCjrHBR2hy523Df5tZWInaheVqSrZGL-KApdAS8Yw5n-oCj7GYKxoQ_9t2AgM4ruhqFuxbdijF3vralEb_Qv-ROuBdAesXWU2_4rE0_NO-AVY0Xps</recordid><startdate>201709</startdate><enddate>201709</enddate><creator>Stankovic, Uros</creator><creator>Ploeger, Lennert S.</creator><creator>Herk, Marcel</creator><creator>Sonke, Jan‐Jakob</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201709</creationdate><title>Optimal combination of anti‐scatter grids and software correction for CBCT imaging</title><author>Stankovic, Uros ; Ploeger, Lennert S. ; Herk, Marcel ; Sonke, Jan‐Jakob</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3875-1950122545edc1bd533daad8d1f3c222d8c8d572845d62caf667e34af130d7183</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>CBCT image quality</topic><topic>Cone-Beam Computed Tomography</topic><topic>Humans</topic><topic>image‐guided radiotherapy</topic><topic>Male</topic><topic>Phantoms, Imaging</topic><topic>Radiotherapy, Image-Guided</topic><topic>Scattering, Radiation</topic><topic>Software</topic><topic>User-Computer Interface</topic><topic>X‐ray scatter</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Stankovic, Uros</creatorcontrib><creatorcontrib>Ploeger, Lennert S.</creatorcontrib><creatorcontrib>Herk, Marcel</creatorcontrib><creatorcontrib>Sonke, Jan‐Jakob</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Medical physics (Lancaster)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Stankovic, Uros</au><au>Ploeger, Lennert S.</au><au>Herk, Marcel</au><au>Sonke, Jan‐Jakob</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Optimal combination of anti‐scatter grids and software correction for CBCT imaging</atitle><jtitle>Medical physics (Lancaster)</jtitle><addtitle>Med Phys</addtitle><date>2017-09</date><risdate>2017</risdate><volume>44</volume><issue>9</issue><spage>4437</spage><epage>4451</epage><pages>4437-4451</pages><issn>0094-2405</issn><eissn>2473-4209</eissn><abstract>Purpose Cone beam computed tomography (CBCT) has been widely adopted in clinical practice for image‐guided radiotherapy. Soft tissue contrast and Hounsfield units are impaired to the presence of scattered radiation. In our previous work, we proposed a high selectivity anti‐scatter grid (ASG) as a possible solution to the problem. An alternative approach is the application of iterative scatter correction using deconvolution with scatter point spread function (PSF). The purpose of this work was to compare the performance of ASGs with different selectivity with and without the iterative and uniform scatter corrections in terms of CBCT image quality. A secondary objective of this study was to develop a novel measurement approach to measure the scatter point spread functions. Methods The scatter PSF was modeled as a sum of two bivariate Gaussian functions. The PSF parameters were estimated from a series of transmission measurements through polystyrene slabs of varying thickness with lead partial beam‐blocker for three different ASG designs ranging from low (5.6), medium (9), and high (11) selectivity. The scatter correction scheme is based on iterative convolution of the current estimate of the primary with the scatter PSF until the root mean square deviation (RMSD) of the measured projection and the sum of the estimate of primary and scatter falls below a predefined threshold. The image quality was evaluated with the CIRS CBCT Image Quality and Electron Density phantom in a head and neck and pelvis configuration and the CIRS Virtual Male Human Patient. The image quality was quantified by the contrast‐to‐noise ratio (CNR) relative to the uncorrected scans and the root mean square deviation of the average gray values for different regions with respect to the nominal Hounsfield units and the mean difference of the reconstructed HU between the planning CT and CBCTs of the virtual human phantom. Results For the head and neck phantom, the CNR increased with more advanced scatter correction algorithm and the ASG selectivity, reaching 3.9, 3.7, 3.5, and 3.1 for the high, medium, light, and with no grid configuration, respectively, combined with the iterative software correction. The same is true for the pelvis phantom with CNR improvement reaching 1.5 for the heavy and medium grid, 1.3 for the light grid, and 1.1 on its own. The HU RMSD for the head and neck phantom was 22 HU, 13 HU, 12 HU, and 6 HU for iterative correction without the grid, with the light grid, medium grid and the heavy grid, respectively. For same correction strategies, the values for the pelvis phantom where 170, 120, 34, and 27 HU. The average difference with the PCT of the virtual human phantom was 59 ± 48 HU and 63 ± 59 HU with scans reconstructed with the iterative correction and two higher selectivity grids. Visual inspection revealed similar trends for a head‐and‐neck and prostate cancer patient. Conclusions The best scatter mitigation strategy was found to be a combination of a grid with selectivity larger than 9, combined with iterative scatter estimation. None of the investigated grids required increasing the imaging dose. The PSF determined using proposed method leads to image quality improvements results for all but one of the investigated scenarios.</abstract><cop>United States</cop><pmid>28556204</pmid><doi>10.1002/mp.12385</doi><tpages>15</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0094-2405
ispartof Medical physics (Lancaster), 2017-09, Vol.44 (9), p.4437-4451
issn 0094-2405
2473-4209
language eng
recordid cdi_proquest_miscellaneous_1903944115
source Wiley
subjects CBCT image quality
Cone-Beam Computed Tomography
Humans
image‐guided radiotherapy
Male
Phantoms, Imaging
Radiotherapy, Image-Guided
Scattering, Radiation
Software
User-Computer Interface
X‐ray scatter
title Optimal combination of anti‐scatter grids and software correction for CBCT imaging
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-24T16%3A14%3A17IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Optimal%20combination%20of%20anti%E2%80%90scatter%20grids%20and%20software%20correction%20for%20CBCT%20imaging&rft.jtitle=Medical%20physics%20(Lancaster)&rft.au=Stankovic,%20Uros&rft.date=2017-09&rft.volume=44&rft.issue=9&rft.spage=4437&rft.epage=4451&rft.pages=4437-4451&rft.issn=0094-2405&rft.eissn=2473-4209&rft_id=info:doi/10.1002/mp.12385&rft_dat=%3Cproquest_cross%3E1903944115%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c3875-1950122545edc1bd533daad8d1f3c222d8c8d572845d62caf667e34af130d7183%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1903944115&rft_id=info:pmid/28556204&rfr_iscdi=true