Loading…
Long-Term Results of Total Hip Arthroplasty with the Cementless Spotorno (CLS) System
Background This study presents the long-term results of the Cementless Spotorno (CLS) total hip arthroplasty system and an analysis of factors associated with clinical and radiographic outcome. Methods We studied a series of 120 consecutive CLS arthroplasties in a young patient group (mean age at su...
Saved in:
Published in: | Hip international 2017-09, Vol.27 (5), p.465-471 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Background
This study presents the long-term results of the Cementless Spotorno (CLS) total hip arthroplasty system and an analysis of factors associated with clinical and radiographic outcome.
Methods
We studied a series of 120 consecutive CLS arthroplasties in a young patient group (mean age at surgery: 55.9 ± 5.9 years). The Merle d'Aubigné-Postel score, polyethylene (PE) wear, and radiographic status were recorded during follow-up. Survival analyses, repeated-measures analysis of variance, and a nested case-control study were used for statistical evaluation.
Results
After a mean follow-up of 14.6 years (range 0.1-24.2 years, including revisions and lost to follow-up), 24 revisions had been performed, 16 of which for aseptic cup loosening. Kaplan-Meier survival analysis showed a 24-year survival of 72.8% (95% CI, 63.0%-82.6%) with revision for any reason as endpoint, and 80.1% (95% CI, 70.9%-89.3%) for revision for aseptic cup loosening. Mean final Merle d'Aubigné-Postel score was 16.1 points (range 7-18). Mean PE wear at final follow-up was 2.3 mm (range 0.6-6.8 mm). A higher rate of PE wear was associated with better clinical scores but also with revision for cup loosening. Factors associated with more PE wear were: younger age at surgery; 32 - mm head; longer follow-up; and steeper inclination angle.
Conclusions
Beyond 10 years, the CLS stem is reliable, but the high revision rate for aseptic cup loosening is concerning, specifically with better performing (cementless) alternatives available. |
---|---|
ISSN: | 1120-7000 1724-6067 |