A targeted noise reduction observational study for reducing noise in a neonatal intensive unit

Background: Excessive noise in neonatal intensive care units (NICUs) can interfere with infants’ growth, development and healing. Local problem: Sound levels in our NICUs exceeded the recommended levels by the World Health Organization. Methods: We implemented a noise reduction strategy in an urban,...

Full description

Saved in:
Bibliographic Details
Published in:Journal of perinatology 2017-09, Vol.37 (9), p.1060-1064
Main Authors: Chawla, S, Barach, P, Dwaihy, M, Kamat, D, Shankaran, S, Panaitescu, B, Wang, B, Natarajan, G
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Background: Excessive noise in neonatal intensive care units (NICUs) can interfere with infants’ growth, development and healing. Local problem: Sound levels in our NICUs exceeded the recommended levels by the World Health Organization. Methods: We implemented a noise reduction strategy in an urban, tertiary academic medical center NICU that included baseline noise measurements. We conducted a survey involving staff and visitors regarding their opinions and perceptions of noise levels in the NICU. Ongoing feedback to staff after each measurement cycle was provided to improve awareness, engagement and adherence with noise reduction strategies. After widespread discussion with active clinician involvement, consensus building and iterative testing, changes were implemented including: lowering of equipment alarm sounds, designated ‘quiet times’ and implementing a customized education program for staff. Interventions: A multiphase noise reduction quality improvement (QI) intervention to reduce ambient sound levels in a patient care room in our NICUs by 3 dB (20%) over 18 months. Results: The noise in the NICU was reduced by 3 dB from baseline. Mean (s.d.) baseline, phase 2 , 3 and 4 noise levels in the two NICUs were: LAeq: 57.0 (0.84), 56.8 (1.6), 55.3 (1.9) and 54.5 (2.6) dB, respectively ( P 90%. Conclusions: Implementing a multipronged QI initiative resulted in significant noise level reduction in two multipod NICUs. It is feasible to reduce noise levels if QI interventions are coupled with active engagement of the clinical staff and following continuous process of improvement methods, measurements and protocols.
ISSN:0743-8346
1476-5543
DOI:10.1038/jp.2017.93