Patient Exposure during Fluoroscopy-guided Pacemaker Implantation Procedures

A pacemaker, which is used for heart resynchronization with electrical impulses, is used to manage many clinical conditions. Recently, the frequency of pacemaker implantation procedures has increased to more than 50% worldwide. During this procedure, patients can be exposed to excessive radiation ex...

Full description

Saved in:
Bibliographic Details
Published in:Applied radiation and isotopes 2018-08, Vol.138, p.14-17
Main Authors: Alkhorayef, M., Sulieman, A., Babikir, E., Daar, E., Alnaaimi, M., Alduaij, M., Bradley, D.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A pacemaker, which is used for heart resynchronization with electrical impulses, is used to manage many clinical conditions. Recently, the frequency of pacemaker implantation procedures has increased to more than 50% worldwide. During this procedure, patients can be exposed to excessive radiation exposure. Wide range of doses has been reported in previous studies, suggesting that optimization of this procedure has not been fulfilled yet. The current study evaluated patient radiation exposure during cardiac pacemaker procedures and quantified the patient effective dose. A total of 145 procedures were performed for five pacemaker procedures (VVI, VVIR, VVD, VVDR, and DDDR) at two hospitals. Patient doses were measured using the kerma-area product meter. Effective doses were estimated using software based on Monte Carlo simulation from the National Radiological Protection Board (NRPB, now The Health Protection Agency). The effective dose values were used to estimate cancer risk from the pacemaker procedure. Patient demographic data and exposure parameters for fluoroscopy and radiography were quantified. The mean patient doses ± SD per procedure (Gy cm2) for VVI, VVIR, VVD, VVDR, and DDDR were 1.52 ± 0.13 (1.43–1.61), 3.28 ± 2.34 (0.29–8.73), 3.04 ± 1.67 (1.57–4.86), 6.04 ± 2.326 3.29–8.58), and 8.8 ± 3.6 (4.5–26.20), respectively. The overall patient effective dose was 1.1 mSv per procedure. It is obvious that the DDDR procedure exposed patients to the highest radiation dose. Patient dose variation can be attributed to procedure type, exposure parameter settings, and fluoroscopy time. The results of this study showed that patient doses during different pacemaker procedures are lower compared to previous reported values. Patient risk from pacemaker procedure is low, compared to other cardiac interventional procedures. Patients' exposures were mainly influenced by the type of procedures and the clinical indication. •Radiation dose measured for pediatric patients undergoing cardiac pacemaker procedure.•Entrance surface air kerma (ESAK) were measured using Kerma Area Product meter.•The patient dose during pacemaker implantation depends upon procedure type and type of fluoroscopic equipment.•Patient dose is within the safety limit and the risk from pacemaker procedures is low.
ISSN:0969-8043
1872-9800
DOI:10.1016/j.apradiso.2017.08.010