Loading…
Cortical auditory evoked potential (CAEP) and behavioural measures of auditory function in a child with a single-sided deafness
To study the changes in behavioural and cortical responses over time in a child with single-sided deafness fitted with a cochlear implant (CI). Cortical auditory evoked potentials (CAEPs) in noise (+5 dB signal-to-noise ratio) were recorded and auditory skills were assessed using tests of sound loca...
Saved in:
Published in: | Cochlear implants international 2017-11, Vol.18 (6), p.335-346 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c224t-cab038da91d09a7c057d872ceefc5d18e042400296b99f0be58a9223aa8e8ea43 |
---|---|
cites | cdi_FETCH-LOGICAL-c224t-cab038da91d09a7c057d872ceefc5d18e042400296b99f0be58a9223aa8e8ea43 |
container_end_page | 346 |
container_issue | 6 |
container_start_page | 335 |
container_title | Cochlear implants international |
container_volume | 18 |
creator | Cañete, Oscar M Purdy, Suzanne C Neeff, Michel Brown, Colin R S Thorne, Peter R |
description | To study the changes in behavioural and cortical responses over time in a child with single-sided deafness fitted with a cochlear implant (CI).
Cortical auditory evoked potentials (CAEPs) in noise (+5 dB signal-to-noise ratio) were recorded and auditory skills were assessed using tests of sound localization, spatial speech perception in noise, and self-ratings of auditory abilities (Listening inventory for education, LIFE and Speech, spatial and qualities of hearing questionnaire, SSQ parental version). Measures were obtained prior to and after a CI fitting, including one, six, and 12 months after the CI switch on.
Spatial speech recognition improved over time. At 12 months post-CI, word recognition scores were similar to those of normal hearing children. Signal-to-noise ratios for sentences decreased (i.e. improved) over time post-CI. Sound localization markedly improved at 12 months post-CI compared to baseline. Self-perception of difficulty scores decreased over time. Parental ratings of hearing abilities improved compared to baseline for all subscales. There were changes in the P1-N1-P2 complex at 12 months post-CI, which were clearer frontally across stimuli. Further research is needed to understand the significance of such changes after CI fitting for single-sided deafness.
Although the changes observed could reflect maturational changes, the clinically significant improvement in recognition of speech in noise and improved questionnaire results suggest that the CI was beneficial, consistent with the feedback from the participant. |
doi_str_mv | 10.1080/14670100.2017.1373499 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1940596570</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1940596570</sourcerecordid><originalsourceid>FETCH-LOGICAL-c224t-cab038da91d09a7c057d872ceefc5d18e042400296b99f0be58a9223aa8e8ea43</originalsourceid><addsrcrecordid>eNpFkE1P3DAQhi3Uqnz1J7TyEQ7Zjh1nbR_RigISEhzKOZrYE9ZtNt7aCRUn_nq9YoHTfL3vjOZh7JuAhQADP4RaahAACwlCL0Sta2XtATsSulGVXkrzqeRFU-1Eh-w4598AtVCN-sIOpbFSWqOO2Msqpik4HDjOPkwxPXN6in_I822caJxCmZytLi7vzzmOnne0xqcQ51TaG8I8J8o89h_mfh7dFOLIw8iRu3UYPP8XpnUpchgfB6py8GW7J-xHyvmUfe5xyPR1H0_Yw8_LX6vr6vbu6mZ1cVs5KdVUOeygNh6t8GBRO2i0N1o6ot41XhgCJRWAtMvO2h46agyWF2tEQ4ZQ1Sfs7HXvNsW_M-Wp3YTsaBhwpDjnVlgFjV02Goq0eZW6FHNO1LfbFDaYnlsB7Y59-8a-3bFv9-yL7_v-xNxtyL-73mDX_wE7doB_</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1940596570</pqid></control><display><type>article</type><title>Cortical auditory evoked potential (CAEP) and behavioural measures of auditory function in a child with a single-sided deafness</title><source>Taylor and Francis:Jisc Collections:Taylor and Francis Read and Publish Agreement 2024-2025:Medical Collection (Reading list)</source><creator>Cañete, Oscar M ; Purdy, Suzanne C ; Neeff, Michel ; Brown, Colin R S ; Thorne, Peter R</creator><creatorcontrib>Cañete, Oscar M ; Purdy, Suzanne C ; Neeff, Michel ; Brown, Colin R S ; Thorne, Peter R</creatorcontrib><description>To study the changes in behavioural and cortical responses over time in a child with single-sided deafness fitted with a cochlear implant (CI).
Cortical auditory evoked potentials (CAEPs) in noise (+5 dB signal-to-noise ratio) were recorded and auditory skills were assessed using tests of sound localization, spatial speech perception in noise, and self-ratings of auditory abilities (Listening inventory for education, LIFE and Speech, spatial and qualities of hearing questionnaire, SSQ parental version). Measures were obtained prior to and after a CI fitting, including one, six, and 12 months after the CI switch on.
Spatial speech recognition improved over time. At 12 months post-CI, word recognition scores were similar to those of normal hearing children. Signal-to-noise ratios for sentences decreased (i.e. improved) over time post-CI. Sound localization markedly improved at 12 months post-CI compared to baseline. Self-perception of difficulty scores decreased over time. Parental ratings of hearing abilities improved compared to baseline for all subscales. There were changes in the P1-N1-P2 complex at 12 months post-CI, which were clearer frontally across stimuli. Further research is needed to understand the significance of such changes after CI fitting for single-sided deafness.
Although the changes observed could reflect maturational changes, the clinically significant improvement in recognition of speech in noise and improved questionnaire results suggest that the CI was beneficial, consistent with the feedback from the participant.</description><identifier>ISSN: 1467-0100</identifier><identifier>EISSN: 1754-7628</identifier><identifier>DOI: 10.1080/14670100.2017.1373499</identifier><identifier>PMID: 28922984</identifier><language>eng</language><publisher>England</publisher><subject>Auditory Cortex - physiopathology ; Child ; Child, Preschool ; Cochlear Implantation - methods ; Cochlear Implants ; Evoked Potentials, Auditory - physiology ; Hearing Loss, Unilateral - physiopathology ; Hearing Loss, Unilateral - surgery ; Humans ; Infant ; Infant, Newborn ; Male ; Noise ; Sound Localization - physiology ; Speech Perception - physiology</subject><ispartof>Cochlear implants international, 2017-11, Vol.18 (6), p.335-346</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c224t-cab038da91d09a7c057d872ceefc5d18e042400296b99f0be58a9223aa8e8ea43</citedby><cites>FETCH-LOGICAL-c224t-cab038da91d09a7c057d872ceefc5d18e042400296b99f0be58a9223aa8e8ea43</cites><orcidid>0000-0003-0214-0210 ; 0000-0002-2622-5086 ; 0000-0001-9978-8173 ; 0000-0003-0040-0437</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/28922984$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Cañete, Oscar M</creatorcontrib><creatorcontrib>Purdy, Suzanne C</creatorcontrib><creatorcontrib>Neeff, Michel</creatorcontrib><creatorcontrib>Brown, Colin R S</creatorcontrib><creatorcontrib>Thorne, Peter R</creatorcontrib><title>Cortical auditory evoked potential (CAEP) and behavioural measures of auditory function in a child with a single-sided deafness</title><title>Cochlear implants international</title><addtitle>Cochlear Implants Int</addtitle><description>To study the changes in behavioural and cortical responses over time in a child with single-sided deafness fitted with a cochlear implant (CI).
Cortical auditory evoked potentials (CAEPs) in noise (+5 dB signal-to-noise ratio) were recorded and auditory skills were assessed using tests of sound localization, spatial speech perception in noise, and self-ratings of auditory abilities (Listening inventory for education, LIFE and Speech, spatial and qualities of hearing questionnaire, SSQ parental version). Measures were obtained prior to and after a CI fitting, including one, six, and 12 months after the CI switch on.
Spatial speech recognition improved over time. At 12 months post-CI, word recognition scores were similar to those of normal hearing children. Signal-to-noise ratios for sentences decreased (i.e. improved) over time post-CI. Sound localization markedly improved at 12 months post-CI compared to baseline. Self-perception of difficulty scores decreased over time. Parental ratings of hearing abilities improved compared to baseline for all subscales. There were changes in the P1-N1-P2 complex at 12 months post-CI, which were clearer frontally across stimuli. Further research is needed to understand the significance of such changes after CI fitting for single-sided deafness.
Although the changes observed could reflect maturational changes, the clinically significant improvement in recognition of speech in noise and improved questionnaire results suggest that the CI was beneficial, consistent with the feedback from the participant.</description><subject>Auditory Cortex - physiopathology</subject><subject>Child</subject><subject>Child, Preschool</subject><subject>Cochlear Implantation - methods</subject><subject>Cochlear Implants</subject><subject>Evoked Potentials, Auditory - physiology</subject><subject>Hearing Loss, Unilateral - physiopathology</subject><subject>Hearing Loss, Unilateral - surgery</subject><subject>Humans</subject><subject>Infant</subject><subject>Infant, Newborn</subject><subject>Male</subject><subject>Noise</subject><subject>Sound Localization - physiology</subject><subject>Speech Perception - physiology</subject><issn>1467-0100</issn><issn>1754-7628</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNpFkE1P3DAQhi3Uqnz1J7TyEQ7Zjh1nbR_RigISEhzKOZrYE9ZtNt7aCRUn_nq9YoHTfL3vjOZh7JuAhQADP4RaahAACwlCL0Sta2XtATsSulGVXkrzqeRFU-1Eh-w4598AtVCN-sIOpbFSWqOO2Msqpik4HDjOPkwxPXN6in_I822caJxCmZytLi7vzzmOnne0xqcQ51TaG8I8J8o89h_mfh7dFOLIw8iRu3UYPP8XpnUpchgfB6py8GW7J-xHyvmUfe5xyPR1H0_Yw8_LX6vr6vbu6mZ1cVs5KdVUOeygNh6t8GBRO2i0N1o6ot41XhgCJRWAtMvO2h46agyWF2tEQ4ZQ1Sfs7HXvNsW_M-Wp3YTsaBhwpDjnVlgFjV02Goq0eZW6FHNO1LfbFDaYnlsB7Y59-8a-3bFv9-yL7_v-xNxtyL-73mDX_wE7doB_</recordid><startdate>20171102</startdate><enddate>20171102</enddate><creator>Cañete, Oscar M</creator><creator>Purdy, Suzanne C</creator><creator>Neeff, Michel</creator><creator>Brown, Colin R S</creator><creator>Thorne, Peter R</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0003-0214-0210</orcidid><orcidid>https://orcid.org/0000-0002-2622-5086</orcidid><orcidid>https://orcid.org/0000-0001-9978-8173</orcidid><orcidid>https://orcid.org/0000-0003-0040-0437</orcidid></search><sort><creationdate>20171102</creationdate><title>Cortical auditory evoked potential (CAEP) and behavioural measures of auditory function in a child with a single-sided deafness</title><author>Cañete, Oscar M ; Purdy, Suzanne C ; Neeff, Michel ; Brown, Colin R S ; Thorne, Peter R</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c224t-cab038da91d09a7c057d872ceefc5d18e042400296b99f0be58a9223aa8e8ea43</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Auditory Cortex - physiopathology</topic><topic>Child</topic><topic>Child, Preschool</topic><topic>Cochlear Implantation - methods</topic><topic>Cochlear Implants</topic><topic>Evoked Potentials, Auditory - physiology</topic><topic>Hearing Loss, Unilateral - physiopathology</topic><topic>Hearing Loss, Unilateral - surgery</topic><topic>Humans</topic><topic>Infant</topic><topic>Infant, Newborn</topic><topic>Male</topic><topic>Noise</topic><topic>Sound Localization - physiology</topic><topic>Speech Perception - physiology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Cañete, Oscar M</creatorcontrib><creatorcontrib>Purdy, Suzanne C</creatorcontrib><creatorcontrib>Neeff, Michel</creatorcontrib><creatorcontrib>Brown, Colin R S</creatorcontrib><creatorcontrib>Thorne, Peter R</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Cochlear implants international</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Cañete, Oscar M</au><au>Purdy, Suzanne C</au><au>Neeff, Michel</au><au>Brown, Colin R S</au><au>Thorne, Peter R</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Cortical auditory evoked potential (CAEP) and behavioural measures of auditory function in a child with a single-sided deafness</atitle><jtitle>Cochlear implants international</jtitle><addtitle>Cochlear Implants Int</addtitle><date>2017-11-02</date><risdate>2017</risdate><volume>18</volume><issue>6</issue><spage>335</spage><epage>346</epage><pages>335-346</pages><issn>1467-0100</issn><eissn>1754-7628</eissn><abstract>To study the changes in behavioural and cortical responses over time in a child with single-sided deafness fitted with a cochlear implant (CI).
Cortical auditory evoked potentials (CAEPs) in noise (+5 dB signal-to-noise ratio) were recorded and auditory skills were assessed using tests of sound localization, spatial speech perception in noise, and self-ratings of auditory abilities (Listening inventory for education, LIFE and Speech, spatial and qualities of hearing questionnaire, SSQ parental version). Measures were obtained prior to and after a CI fitting, including one, six, and 12 months after the CI switch on.
Spatial speech recognition improved over time. At 12 months post-CI, word recognition scores were similar to those of normal hearing children. Signal-to-noise ratios for sentences decreased (i.e. improved) over time post-CI. Sound localization markedly improved at 12 months post-CI compared to baseline. Self-perception of difficulty scores decreased over time. Parental ratings of hearing abilities improved compared to baseline for all subscales. There were changes in the P1-N1-P2 complex at 12 months post-CI, which were clearer frontally across stimuli. Further research is needed to understand the significance of such changes after CI fitting for single-sided deafness.
Although the changes observed could reflect maturational changes, the clinically significant improvement in recognition of speech in noise and improved questionnaire results suggest that the CI was beneficial, consistent with the feedback from the participant.</abstract><cop>England</cop><pmid>28922984</pmid><doi>10.1080/14670100.2017.1373499</doi><tpages>12</tpages><orcidid>https://orcid.org/0000-0003-0214-0210</orcidid><orcidid>https://orcid.org/0000-0002-2622-5086</orcidid><orcidid>https://orcid.org/0000-0001-9978-8173</orcidid><orcidid>https://orcid.org/0000-0003-0040-0437</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1467-0100 |
ispartof | Cochlear implants international, 2017-11, Vol.18 (6), p.335-346 |
issn | 1467-0100 1754-7628 |
language | eng |
recordid | cdi_proquest_miscellaneous_1940596570 |
source | Taylor and Francis:Jisc Collections:Taylor and Francis Read and Publish Agreement 2024-2025:Medical Collection (Reading list) |
subjects | Auditory Cortex - physiopathology Child Child, Preschool Cochlear Implantation - methods Cochlear Implants Evoked Potentials, Auditory - physiology Hearing Loss, Unilateral - physiopathology Hearing Loss, Unilateral - surgery Humans Infant Infant, Newborn Male Noise Sound Localization - physiology Speech Perception - physiology |
title | Cortical auditory evoked potential (CAEP) and behavioural measures of auditory function in a child with a single-sided deafness |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-02T13%3A14%3A20IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Cortical%20auditory%20evoked%20potential%20(CAEP)%20and%20behavioural%20measures%20of%20auditory%20function%20in%20a%20child%20with%20a%20single-sided%20deafness&rft.jtitle=Cochlear%20implants%20international&rft.au=Ca%C3%B1ete,%20Oscar%20M&rft.date=2017-11-02&rft.volume=18&rft.issue=6&rft.spage=335&rft.epage=346&rft.pages=335-346&rft.issn=1467-0100&rft.eissn=1754-7628&rft_id=info:doi/10.1080/14670100.2017.1373499&rft_dat=%3Cproquest_cross%3E1940596570%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c224t-cab038da91d09a7c057d872ceefc5d18e042400296b99f0be58a9223aa8e8ea43%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1940596570&rft_id=info:pmid/28922984&rfr_iscdi=true |