Loading…

Two‐year extractability of novel left ventricular, active fixation leads in the sheep model

Background A cardiac lead with a side helix for active fixation to the coronary vein wall (Attain Stability®, Model 20066, Medtronic, Minneapolis, MN, USA) recently received CE Mark. The lead is designed to improve left ventricular (LV) placement and reduce dislodgement rates. The extractability of...

Full description

Saved in:
Bibliographic Details
Published in:Pacing and clinical electrophysiology 2017-11, Vol.40 (11), p.1291-1297
Main Authors: Adler, Stuart, Kirchhof, Nicole, Thompson, Amy E., Foerster, Laurie, Marquard, Kyle R., Hine, Douglas S.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Background A cardiac lead with a side helix for active fixation to the coronary vein wall (Attain Stability®, Model 20066, Medtronic, Minneapolis, MN, USA) recently received CE Mark. The lead is designed to improve left ventricular (LV) placement and reduce dislodgement rates. The extractability of this active fixation LV lead has not been studied extensively. Methods Seventeen sheep were implanted with either an LV lead with a side helix (Model 20066, Model 20096, Medtronic) or a unipolar LV lead (Model 4193, Medtronic) as a control. Leads were extracted at approximately 26, 52, or 118 weeks. Standard extraction methodology was employed with quantitative traction up to 907 g (2 lbs.) using a locking stylet. Gross pathology and histology of the heart with particular attention to the lead tracts were performed. Results All leads were successfully removed in their entirety and required significantly less than 1 kg of traction force. The side helix disengaged from the vein as designed and resulted in no complications. No cardiac tissue was observed on any extracted lead. Gross pathology and histology were devoid of any helix‐induced lesions in the vascular structures. The epicardium over the side helix was normal and the fibrotic reaction around the helix was not significantly different from that around the nonhelix portions of the study leads or the control lead. Conclusion Extraction of the side helix, active fixation LV lead from the coronary veins in the sheep model is safe, without procedural complexity, and free of complications after long‐term LV lead implant duration.
ISSN:0147-8389
1540-8159
DOI:10.1111/pace.13200