Does the Additional Articulation in Retrieved Bipolar Hemiarthroplasty Implants Decrease Trunnionosis Compared to Total Hip Arthroplasty?

Trunnionosis at the modular head-neck taper interface in metal-on-polyethylene total hip arthroplasty (MoP THA) has been shown to occur, and represents a potential mode of MoP THA failure. The purpose of the present investigation is to elucidate differences in fretting and corrosion at the head-neck...

Full description

Saved in:
Bibliographic Details
Published in:The Journal of arthroplasty 2018-01, Vol.33 (1), p.268-272
Main Authors: Del Balso, Christopher, Teeter, Matthew G., Tan, Sok C., Lanting, Brent A., Howard, James L.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c356t-231b5ef8a3067f134a4f110cf236b931d97b7d749d8d6ae90069187ffc82b6963
cites cdi_FETCH-LOGICAL-c356t-231b5ef8a3067f134a4f110cf236b931d97b7d749d8d6ae90069187ffc82b6963
container_end_page 272
container_issue 1
container_start_page 268
container_title The Journal of arthroplasty
container_volume 33
creator Del Balso, Christopher
Teeter, Matthew G.
Tan, Sok C.
Lanting, Brent A.
Howard, James L.
description Trunnionosis at the modular head-neck taper interface in metal-on-polyethylene total hip arthroplasty (MoP THA) has been shown to occur, and represents a potential mode of MoP THA failure. The purpose of the present investigation is to elucidate differences in fretting and corrosion at the head-neck taper interface of prostheses retrieved from bipolar hemiarthroplasty (BH) and MoP THA. A retrieval analysis of BH and MoP THA prostheses featuring a single taper design from a single manufacturer and in vivo for a minimum 2 years was performed. Fifteen femoral heads of 28-mm diameter and corresponding femoral stems retrieved from BH were compared with MoP THA implants matched based on time in vivo and head length (28 mm, −3 mm to 28 mm, +8 mm). Fretting and corrosion damage scoring was completed under stereomicroscopic visualization. Femoral head bore tapers retrieved from BH exhibited decreased overall fretting (P = .02), when compared to those retrieved from MoP THA. Total corrosion scores for all retrieved implants were positively correlated with implantation time (ρ = 0.54, P < .02). Femoral heads retrieved from BH exhibit decreased fretting damage compared to those retrieved from MoP THA. The added articulation in BH implants may decrease torque produced at the head-neck taper junction, thereby decreasing fretting. Increased fretting damage in implants from MoP THA is not associated with increased corrosion in 28-mm heads of this taper design. The longer a BH or MoP THA prosthesis is implanted, the greater the risk of damage due to corrosion.
doi_str_mv 10.1016/j.arth.2017.08.027
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1951568763</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0883540317307507</els_id><sourcerecordid>1951568763</sourcerecordid><originalsourceid>FETCH-LOGICAL-c356t-231b5ef8a3067f134a4f110cf236b931d97b7d749d8d6ae90069187ffc82b6963</originalsourceid><addsrcrecordid>eNp9kc9q3DAQxkVoSTZpXiCHoGMvdiTLlmUolM3mzwYChbI5C1kaEy225UpyII-Qt47MpjnmNDPwze-T5kPogpKcEsqv9rny8TkvCK1zInJS1EdoRStWZKIk_BtaESFYVpWEnaDTEPaEUFpV5TE6KRrCWOpX6O3GQcDxGfDaGButG1WP1z5aPfdqGbEd8V-I3sILGHxtJ9crj7cw2MXcu6lXIb7ihyE1Ywz4BrQHFQDv_DyOCeCCDXjjhkn5BIgO71xMHls7LT6fhN8_0PdO9QHOP-oZerq73W222eOf-4fN-jHTrOIxKxhtK-iEYoTXHWWlKjtKie4KxtuGUdPUbW3qsjHCcAUNIbyhou46LYqWN5ydoZ8H7uTdvxlClIMNGvr0fHBzkLSpaMVFzVmSFgep9i4ED52cvB2Uf5WUyCUCuZfLFeQSgSRCpgjS0uUHf24HMJ8r_2-eBL8OAki_fLHgZdAWRg3GetBRGme_4r8D1UOaGg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1951568763</pqid></control><display><type>article</type><title>Does the Additional Articulation in Retrieved Bipolar Hemiarthroplasty Implants Decrease Trunnionosis Compared to Total Hip Arthroplasty?</title><source>Elsevier</source><creator>Del Balso, Christopher ; Teeter, Matthew G. ; Tan, Sok C. ; Lanting, Brent A. ; Howard, James L.</creator><creatorcontrib>Del Balso, Christopher ; Teeter, Matthew G. ; Tan, Sok C. ; Lanting, Brent A. ; Howard, James L.</creatorcontrib><description>Trunnionosis at the modular head-neck taper interface in metal-on-polyethylene total hip arthroplasty (MoP THA) has been shown to occur, and represents a potential mode of MoP THA failure. The purpose of the present investigation is to elucidate differences in fretting and corrosion at the head-neck taper interface of prostheses retrieved from bipolar hemiarthroplasty (BH) and MoP THA. A retrieval analysis of BH and MoP THA prostheses featuring a single taper design from a single manufacturer and in vivo for a minimum 2 years was performed. Fifteen femoral heads of 28-mm diameter and corresponding femoral stems retrieved from BH were compared with MoP THA implants matched based on time in vivo and head length (28 mm, −3 mm to 28 mm, +8 mm). Fretting and corrosion damage scoring was completed under stereomicroscopic visualization. Femoral head bore tapers retrieved from BH exhibited decreased overall fretting (P = .02), when compared to those retrieved from MoP THA. Total corrosion scores for all retrieved implants were positively correlated with implantation time (ρ = 0.54, P &lt; .02). Femoral heads retrieved from BH exhibit decreased fretting damage compared to those retrieved from MoP THA. The added articulation in BH implants may decrease torque produced at the head-neck taper junction, thereby decreasing fretting. Increased fretting damage in implants from MoP THA is not associated with increased corrosion in 28-mm heads of this taper design. The longer a BH or MoP THA prosthesis is implanted, the greater the risk of damage due to corrosion.</description><identifier>ISSN: 0883-5403</identifier><identifier>EISSN: 1532-8406</identifier><identifier>DOI: 10.1016/j.arth.2017.08.027</identifier><identifier>PMID: 29033155</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>bipolar hemiarthroplasty ; corrosion ; fretting ; total hip arthroplasty ; trunnionosis</subject><ispartof>The Journal of arthroplasty, 2018-01, Vol.33 (1), p.268-272</ispartof><rights>2017</rights><rights>Copyright © 2017. Published by Elsevier Inc.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c356t-231b5ef8a3067f134a4f110cf236b931d97b7d749d8d6ae90069187ffc82b6963</citedby><cites>FETCH-LOGICAL-c356t-231b5ef8a3067f134a4f110cf236b931d97b7d749d8d6ae90069187ffc82b6963</cites><orcidid>0000-0003-4074-6424</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29033155$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Del Balso, Christopher</creatorcontrib><creatorcontrib>Teeter, Matthew G.</creatorcontrib><creatorcontrib>Tan, Sok C.</creatorcontrib><creatorcontrib>Lanting, Brent A.</creatorcontrib><creatorcontrib>Howard, James L.</creatorcontrib><title>Does the Additional Articulation in Retrieved Bipolar Hemiarthroplasty Implants Decrease Trunnionosis Compared to Total Hip Arthroplasty?</title><title>The Journal of arthroplasty</title><addtitle>J Arthroplasty</addtitle><description>Trunnionosis at the modular head-neck taper interface in metal-on-polyethylene total hip arthroplasty (MoP THA) has been shown to occur, and represents a potential mode of MoP THA failure. The purpose of the present investigation is to elucidate differences in fretting and corrosion at the head-neck taper interface of prostheses retrieved from bipolar hemiarthroplasty (BH) and MoP THA. A retrieval analysis of BH and MoP THA prostheses featuring a single taper design from a single manufacturer and in vivo for a minimum 2 years was performed. Fifteen femoral heads of 28-mm diameter and corresponding femoral stems retrieved from BH were compared with MoP THA implants matched based on time in vivo and head length (28 mm, −3 mm to 28 mm, +8 mm). Fretting and corrosion damage scoring was completed under stereomicroscopic visualization. Femoral head bore tapers retrieved from BH exhibited decreased overall fretting (P = .02), when compared to those retrieved from MoP THA. Total corrosion scores for all retrieved implants were positively correlated with implantation time (ρ = 0.54, P &lt; .02). Femoral heads retrieved from BH exhibit decreased fretting damage compared to those retrieved from MoP THA. The added articulation in BH implants may decrease torque produced at the head-neck taper junction, thereby decreasing fretting. Increased fretting damage in implants from MoP THA is not associated with increased corrosion in 28-mm heads of this taper design. The longer a BH or MoP THA prosthesis is implanted, the greater the risk of damage due to corrosion.</description><subject>bipolar hemiarthroplasty</subject><subject>corrosion</subject><subject>fretting</subject><subject>total hip arthroplasty</subject><subject>trunnionosis</subject><issn>0883-5403</issn><issn>1532-8406</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNp9kc9q3DAQxkVoSTZpXiCHoGMvdiTLlmUolM3mzwYChbI5C1kaEy225UpyII-Qt47MpjnmNDPwze-T5kPogpKcEsqv9rny8TkvCK1zInJS1EdoRStWZKIk_BtaESFYVpWEnaDTEPaEUFpV5TE6KRrCWOpX6O3GQcDxGfDaGButG1WP1z5aPfdqGbEd8V-I3sILGHxtJ9crj7cw2MXcu6lXIb7ihyE1Ywz4BrQHFQDv_DyOCeCCDXjjhkn5BIgO71xMHls7LT6fhN8_0PdO9QHOP-oZerq73W222eOf-4fN-jHTrOIxKxhtK-iEYoTXHWWlKjtKie4KxtuGUdPUbW3qsjHCcAUNIbyhou46LYqWN5ydoZ8H7uTdvxlClIMNGvr0fHBzkLSpaMVFzVmSFgep9i4ED52cvB2Uf5WUyCUCuZfLFeQSgSRCpgjS0uUHf24HMJ8r_2-eBL8OAki_fLHgZdAWRg3GetBRGme_4r8D1UOaGg</recordid><startdate>201801</startdate><enddate>201801</enddate><creator>Del Balso, Christopher</creator><creator>Teeter, Matthew G.</creator><creator>Tan, Sok C.</creator><creator>Lanting, Brent A.</creator><creator>Howard, James L.</creator><general>Elsevier Inc</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0003-4074-6424</orcidid></search><sort><creationdate>201801</creationdate><title>Does the Additional Articulation in Retrieved Bipolar Hemiarthroplasty Implants Decrease Trunnionosis Compared to Total Hip Arthroplasty?</title><author>Del Balso, Christopher ; Teeter, Matthew G. ; Tan, Sok C. ; Lanting, Brent A. ; Howard, James L.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c356t-231b5ef8a3067f134a4f110cf236b931d97b7d749d8d6ae90069187ffc82b6963</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>bipolar hemiarthroplasty</topic><topic>corrosion</topic><topic>fretting</topic><topic>total hip arthroplasty</topic><topic>trunnionosis</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Del Balso, Christopher</creatorcontrib><creatorcontrib>Teeter, Matthew G.</creatorcontrib><creatorcontrib>Tan, Sok C.</creatorcontrib><creatorcontrib>Lanting, Brent A.</creatorcontrib><creatorcontrib>Howard, James L.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The Journal of arthroplasty</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Del Balso, Christopher</au><au>Teeter, Matthew G.</au><au>Tan, Sok C.</au><au>Lanting, Brent A.</au><au>Howard, James L.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Does the Additional Articulation in Retrieved Bipolar Hemiarthroplasty Implants Decrease Trunnionosis Compared to Total Hip Arthroplasty?</atitle><jtitle>The Journal of arthroplasty</jtitle><addtitle>J Arthroplasty</addtitle><date>2018-01</date><risdate>2018</risdate><volume>33</volume><issue>1</issue><spage>268</spage><epage>272</epage><pages>268-272</pages><issn>0883-5403</issn><eissn>1532-8406</eissn><abstract>Trunnionosis at the modular head-neck taper interface in metal-on-polyethylene total hip arthroplasty (MoP THA) has been shown to occur, and represents a potential mode of MoP THA failure. The purpose of the present investigation is to elucidate differences in fretting and corrosion at the head-neck taper interface of prostheses retrieved from bipolar hemiarthroplasty (BH) and MoP THA. A retrieval analysis of BH and MoP THA prostheses featuring a single taper design from a single manufacturer and in vivo for a minimum 2 years was performed. Fifteen femoral heads of 28-mm diameter and corresponding femoral stems retrieved from BH were compared with MoP THA implants matched based on time in vivo and head length (28 mm, −3 mm to 28 mm, +8 mm). Fretting and corrosion damage scoring was completed under stereomicroscopic visualization. Femoral head bore tapers retrieved from BH exhibited decreased overall fretting (P = .02), when compared to those retrieved from MoP THA. Total corrosion scores for all retrieved implants were positively correlated with implantation time (ρ = 0.54, P &lt; .02). Femoral heads retrieved from BH exhibit decreased fretting damage compared to those retrieved from MoP THA. The added articulation in BH implants may decrease torque produced at the head-neck taper junction, thereby decreasing fretting. Increased fretting damage in implants from MoP THA is not associated with increased corrosion in 28-mm heads of this taper design. The longer a BH or MoP THA prosthesis is implanted, the greater the risk of damage due to corrosion.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>29033155</pmid><doi>10.1016/j.arth.2017.08.027</doi><tpages>5</tpages><orcidid>https://orcid.org/0000-0003-4074-6424</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0883-5403
ispartof The Journal of arthroplasty, 2018-01, Vol.33 (1), p.268-272
issn 0883-5403
1532-8406
language eng
recordid cdi_proquest_miscellaneous_1951568763
source Elsevier
subjects bipolar hemiarthroplasty
corrosion
fretting
total hip arthroplasty
trunnionosis
title Does the Additional Articulation in Retrieved Bipolar Hemiarthroplasty Implants Decrease Trunnionosis Compared to Total Hip Arthroplasty?
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T18%3A58%3A18IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Does%20the%20Additional%20Articulation%20in%20Retrieved%20Bipolar%20Hemiarthroplasty%20Implants%20Decrease%20Trunnionosis%20Compared%20to%20Total%20Hip%20Arthroplasty?&rft.jtitle=The%20Journal%20of%20arthroplasty&rft.au=Del%20Balso,%20Christopher&rft.date=2018-01&rft.volume=33&rft.issue=1&rft.spage=268&rft.epage=272&rft.pages=268-272&rft.issn=0883-5403&rft.eissn=1532-8406&rft_id=info:doi/10.1016/j.arth.2017.08.027&rft_dat=%3Cproquest_cross%3E1951568763%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c356t-231b5ef8a3067f134a4f110cf236b931d97b7d749d8d6ae90069187ffc82b6963%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1951568763&rft_id=info:pmid/29033155&rfr_iscdi=true