Defibrillation of soft porous metal-organic frameworks with electric fields

Gas transport through metal-organic framework membranes (MOFs) was switched in situ by applying an external electric field (E-field). The switching of gas permeation upon E-field polarization could be explained by the structural transformation of the zeolitic imidazolate framework ZIF-8 into polymor...

Full description

Saved in:
Bibliographic Details
Published in:Science (American Association for the Advancement of Science) 2017-10, Vol.358 (6361), p.347-351
Main Authors: Knebel, A., Geppert, B., Volgmann, K., Kolokolov, D. I., Stepanov, A. G., Twiefel, J., Heitjans, P., Volkmer, D., Caro, J.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c425t-2c1734090fd486c1b432f3b6de2d7bc4e12cfde3392d82837ad0d5d882d8e4573
cites cdi_FETCH-LOGICAL-c425t-2c1734090fd486c1b432f3b6de2d7bc4e12cfde3392d82837ad0d5d882d8e4573
container_end_page 351
container_issue 6361
container_start_page 347
container_title Science (American Association for the Advancement of Science)
container_volume 358
creator Knebel, A.
Geppert, B.
Volgmann, K.
Kolokolov, D. I.
Stepanov, A. G.
Twiefel, J.
Heitjans, P.
Volkmer, D.
Caro, J.
description Gas transport through metal-organic framework membranes (MOFs) was switched in situ by applying an external electric field (E-field). The switching of gas permeation upon E-field polarization could be explained by the structural transformation of the zeolitic imidazolate framework ZIF-8 into polymorphs with more rigid lattices. Permeation measurements under a direct-current E-field poling of 500 volts per millimeter showed reversibly controlled switching of the ZIF-8 into polar polymorphs, which was confirmed by x-ray diffraction and ab initio calculations. The stiffening of the lattice causes a reduction in gas transport through the membrane and sharpens the molecular sieving capability. Dielectric spectroscopy, polarization, and deuterium nuclear magnetic resonance studies revealed low-frequency resonances of ZIF-8 that we attribute to lattice flexibility and linker movement. Upon E-field polarization, we observed a defibrillation of the different lattice motions.
doi_str_mv 10.1126/science.aal2456
format article
fullrecord <record><control><sourceid>jstor_proqu</sourceid><recordid>TN_cdi_proquest_miscellaneous_1954068664</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><jstor_id>26400567</jstor_id><sourcerecordid>26400567</sourcerecordid><originalsourceid>FETCH-LOGICAL-c425t-2c1734090fd486c1b432f3b6de2d7bc4e12cfde3392d82837ad0d5d882d8e4573</originalsourceid><addsrcrecordid>eNpdkLtPwzAQhy0EouUxM4EisbCk9TvJiMpTVGKBOXLsM7gkcbFTVfz3uGoBiel0-n13uvsQOiN4QgiV06gd9BomSrWUC7mHxgRXIq8oZvtojDGTeYkLMUJHMS4wTlnFDtGIVlgQVsgxeroB65rg2lYNzveZt1n0dsiWPvhVzDoYVJv78KZ6pzMbVAdrHz5itnbDewYt6CFsAgetiSfowKo2wumuHqPXu9uX2UM-f75_nF3Pc82pGHKqScE4rrA1vJSaNJxRyxppgJqi0RwI1dYAYxU1JS1ZoQw2wpRlaoGLgh2jq-3eZfCfK4hD3bmoIb3QQzq6JpXgWJZS8oRe_kMXfhX6dF2iCpEEcVYmarqldPAxBrD1MrhOha-a4Hrjud55rnee08TFbu-q6cD88j9iE3C-BRZx8OEvlxxjIQv2DSfbhK8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1975003438</pqid></control><display><type>article</type><title>Defibrillation of soft porous metal-organic frameworks with electric fields</title><source>American Association for the Advancement of Science</source><source>JSTOR-E-Journals</source><source>Alma/SFX Local Collection</source><creator>Knebel, A. ; Geppert, B. ; Volgmann, K. ; Kolokolov, D. I. ; Stepanov, A. G. ; Twiefel, J. ; Heitjans, P. ; Volkmer, D. ; Caro, J.</creator><creatorcontrib>Knebel, A. ; Geppert, B. ; Volgmann, K. ; Kolokolov, D. I. ; Stepanov, A. G. ; Twiefel, J. ; Heitjans, P. ; Volkmer, D. ; Caro, J.</creatorcontrib><description>Gas transport through metal-organic framework membranes (MOFs) was switched in situ by applying an external electric field (E-field). The switching of gas permeation upon E-field polarization could be explained by the structural transformation of the zeolitic imidazolate framework ZIF-8 into polymorphs with more rigid lattices. Permeation measurements under a direct-current E-field poling of 500 volts per millimeter showed reversibly controlled switching of the ZIF-8 into polar polymorphs, which was confirmed by x-ray diffraction and ab initio calculations. The stiffening of the lattice causes a reduction in gas transport through the membrane and sharpens the molecular sieving capability. Dielectric spectroscopy, polarization, and deuterium nuclear magnetic resonance studies revealed low-frequency resonances of ZIF-8 that we attribute to lattice flexibility and linker movement. Upon E-field polarization, we observed a defibrillation of the different lattice motions.</description><identifier>ISSN: 0036-8075</identifier><identifier>EISSN: 1095-9203</identifier><identifier>DOI: 10.1126/science.aal2456</identifier><identifier>PMID: 29051376</identifier><language>eng</language><publisher>United States: American Association for the Advancement of Science</publisher><subject>Deformation ; Deformation mechanisms ; Deoxidizing ; Deuterium ; Electric fields ; Gas mixtures ; Gas permeation ; Gas transport ; Lattices ; Membranes ; Metal-organic frameworks ; Metals ; NMR ; Nuclear magnetic resonance ; Penetration ; Polarization ; Porosity ; Spectroscopy ; Stiffening ; Switching ; X-ray diffraction</subject><ispartof>Science (American Association for the Advancement of Science), 2017-10, Vol.358 (6361), p.347-351</ispartof><rights>Copyright © 2017 by the American Association for the Advancement of Science</rights><rights>Copyright © 2017 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.</rights><rights>Copyright © 2017 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c425t-2c1734090fd486c1b432f3b6de2d7bc4e12cfde3392d82837ad0d5d882d8e4573</citedby><cites>FETCH-LOGICAL-c425t-2c1734090fd486c1b432f3b6de2d7bc4e12cfde3392d82837ad0d5d882d8e4573</cites><orcidid>0000-0002-5866-1106 ; 0000-0002-8105-2157 ; 0000-0002-5759-1134 ; 0000-0003-2754-5273 ; 0000-0003-0931-085X ; 0000-0003-2437-9011 ; 0000-0002-1434-095X</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.jstor.org/stable/pdf/26400567$$EPDF$$P50$$Gjstor$$H</linktopdf><linktohtml>$$Uhttps://www.jstor.org/stable/26400567$$EHTML$$P50$$Gjstor$$H</linktohtml><link.rule.ids>314,780,784,2884,2885,27924,27925,58238,58471</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29051376$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Knebel, A.</creatorcontrib><creatorcontrib>Geppert, B.</creatorcontrib><creatorcontrib>Volgmann, K.</creatorcontrib><creatorcontrib>Kolokolov, D. I.</creatorcontrib><creatorcontrib>Stepanov, A. G.</creatorcontrib><creatorcontrib>Twiefel, J.</creatorcontrib><creatorcontrib>Heitjans, P.</creatorcontrib><creatorcontrib>Volkmer, D.</creatorcontrib><creatorcontrib>Caro, J.</creatorcontrib><title>Defibrillation of soft porous metal-organic frameworks with electric fields</title><title>Science (American Association for the Advancement of Science)</title><addtitle>Science</addtitle><description>Gas transport through metal-organic framework membranes (MOFs) was switched in situ by applying an external electric field (E-field). The switching of gas permeation upon E-field polarization could be explained by the structural transformation of the zeolitic imidazolate framework ZIF-8 into polymorphs with more rigid lattices. Permeation measurements under a direct-current E-field poling of 500 volts per millimeter showed reversibly controlled switching of the ZIF-8 into polar polymorphs, which was confirmed by x-ray diffraction and ab initio calculations. The stiffening of the lattice causes a reduction in gas transport through the membrane and sharpens the molecular sieving capability. Dielectric spectroscopy, polarization, and deuterium nuclear magnetic resonance studies revealed low-frequency resonances of ZIF-8 that we attribute to lattice flexibility and linker movement. Upon E-field polarization, we observed a defibrillation of the different lattice motions.</description><subject>Deformation</subject><subject>Deformation mechanisms</subject><subject>Deoxidizing</subject><subject>Deuterium</subject><subject>Electric fields</subject><subject>Gas mixtures</subject><subject>Gas permeation</subject><subject>Gas transport</subject><subject>Lattices</subject><subject>Membranes</subject><subject>Metal-organic frameworks</subject><subject>Metals</subject><subject>NMR</subject><subject>Nuclear magnetic resonance</subject><subject>Penetration</subject><subject>Polarization</subject><subject>Porosity</subject><subject>Spectroscopy</subject><subject>Stiffening</subject><subject>Switching</subject><subject>X-ray diffraction</subject><issn>0036-8075</issn><issn>1095-9203</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNpdkLtPwzAQhy0EouUxM4EisbCk9TvJiMpTVGKBOXLsM7gkcbFTVfz3uGoBiel0-n13uvsQOiN4QgiV06gd9BomSrWUC7mHxgRXIq8oZvtojDGTeYkLMUJHMS4wTlnFDtGIVlgQVsgxeroB65rg2lYNzveZt1n0dsiWPvhVzDoYVJv78KZ6pzMbVAdrHz5itnbDewYt6CFsAgetiSfowKo2wumuHqPXu9uX2UM-f75_nF3Pc82pGHKqScE4rrA1vJSaNJxRyxppgJqi0RwI1dYAYxU1JS1ZoQw2wpRlaoGLgh2jq-3eZfCfK4hD3bmoIb3QQzq6JpXgWJZS8oRe_kMXfhX6dF2iCpEEcVYmarqldPAxBrD1MrhOha-a4Hrjud55rnee08TFbu-q6cD88j9iE3C-BRZx8OEvlxxjIQv2DSfbhK8</recordid><startdate>20171020</startdate><enddate>20171020</enddate><creator>Knebel, A.</creator><creator>Geppert, B.</creator><creator>Volgmann, K.</creator><creator>Kolokolov, D. I.</creator><creator>Stepanov, A. G.</creator><creator>Twiefel, J.</creator><creator>Heitjans, P.</creator><creator>Volkmer, D.</creator><creator>Caro, J.</creator><general>American Association for the Advancement of Science</general><general>The American Association for the Advancement of Science</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QF</scope><scope>7QG</scope><scope>7QL</scope><scope>7QP</scope><scope>7QQ</scope><scope>7QR</scope><scope>7SC</scope><scope>7SE</scope><scope>7SN</scope><scope>7SP</scope><scope>7SR</scope><scope>7SS</scope><scope>7T7</scope><scope>7TA</scope><scope>7TB</scope><scope>7TK</scope><scope>7TM</scope><scope>7U5</scope><scope>7U9</scope><scope>8BQ</scope><scope>8FD</scope><scope>C1K</scope><scope>F28</scope><scope>FR3</scope><scope>H8D</scope><scope>H8G</scope><scope>H94</scope><scope>JG9</scope><scope>JQ2</scope><scope>K9.</scope><scope>KR7</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>M7N</scope><scope>P64</scope><scope>RC3</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-5866-1106</orcidid><orcidid>https://orcid.org/0000-0002-8105-2157</orcidid><orcidid>https://orcid.org/0000-0002-5759-1134</orcidid><orcidid>https://orcid.org/0000-0003-2754-5273</orcidid><orcidid>https://orcid.org/0000-0003-0931-085X</orcidid><orcidid>https://orcid.org/0000-0003-2437-9011</orcidid><orcidid>https://orcid.org/0000-0002-1434-095X</orcidid></search><sort><creationdate>20171020</creationdate><title>Defibrillation of soft porous metal-organic frameworks with electric fields</title><author>Knebel, A. ; Geppert, B. ; Volgmann, K. ; Kolokolov, D. I. ; Stepanov, A. G. ; Twiefel, J. ; Heitjans, P. ; Volkmer, D. ; Caro, J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c425t-2c1734090fd486c1b432f3b6de2d7bc4e12cfde3392d82837ad0d5d882d8e4573</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Deformation</topic><topic>Deformation mechanisms</topic><topic>Deoxidizing</topic><topic>Deuterium</topic><topic>Electric fields</topic><topic>Gas mixtures</topic><topic>Gas permeation</topic><topic>Gas transport</topic><topic>Lattices</topic><topic>Membranes</topic><topic>Metal-organic frameworks</topic><topic>Metals</topic><topic>NMR</topic><topic>Nuclear magnetic resonance</topic><topic>Penetration</topic><topic>Polarization</topic><topic>Porosity</topic><topic>Spectroscopy</topic><topic>Stiffening</topic><topic>Switching</topic><topic>X-ray diffraction</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Knebel, A.</creatorcontrib><creatorcontrib>Geppert, B.</creatorcontrib><creatorcontrib>Volgmann, K.</creatorcontrib><creatorcontrib>Kolokolov, D. I.</creatorcontrib><creatorcontrib>Stepanov, A. G.</creatorcontrib><creatorcontrib>Twiefel, J.</creatorcontrib><creatorcontrib>Heitjans, P.</creatorcontrib><creatorcontrib>Volkmer, D.</creatorcontrib><creatorcontrib>Caro, J.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>Aluminium Industry Abstracts</collection><collection>Animal Behavior Abstracts</collection><collection>Bacteriology Abstracts (Microbiology B)</collection><collection>Calcium &amp; Calcified Tissue Abstracts</collection><collection>Ceramic Abstracts</collection><collection>Chemoreception Abstracts</collection><collection>Computer and Information Systems Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Ecology Abstracts</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Entomology Abstracts (Full archive)</collection><collection>Industrial and Applied Microbiology Abstracts (Microbiology A)</collection><collection>Materials Business File</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Neurosciences Abstracts</collection><collection>Nucleic Acids Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Virology and AIDS Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Copper Technical Reference Library</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts – Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Algology Mycology and Protozoology Abstracts (Microbiology C)</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>Genetics Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Science (American Association for the Advancement of Science)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Knebel, A.</au><au>Geppert, B.</au><au>Volgmann, K.</au><au>Kolokolov, D. I.</au><au>Stepanov, A. G.</au><au>Twiefel, J.</au><au>Heitjans, P.</au><au>Volkmer, D.</au><au>Caro, J.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Defibrillation of soft porous metal-organic frameworks with electric fields</atitle><jtitle>Science (American Association for the Advancement of Science)</jtitle><addtitle>Science</addtitle><date>2017-10-20</date><risdate>2017</risdate><volume>358</volume><issue>6361</issue><spage>347</spage><epage>351</epage><pages>347-351</pages><issn>0036-8075</issn><eissn>1095-9203</eissn><abstract>Gas transport through metal-organic framework membranes (MOFs) was switched in situ by applying an external electric field (E-field). The switching of gas permeation upon E-field polarization could be explained by the structural transformation of the zeolitic imidazolate framework ZIF-8 into polymorphs with more rigid lattices. Permeation measurements under a direct-current E-field poling of 500 volts per millimeter showed reversibly controlled switching of the ZIF-8 into polar polymorphs, which was confirmed by x-ray diffraction and ab initio calculations. The stiffening of the lattice causes a reduction in gas transport through the membrane and sharpens the molecular sieving capability. Dielectric spectroscopy, polarization, and deuterium nuclear magnetic resonance studies revealed low-frequency resonances of ZIF-8 that we attribute to lattice flexibility and linker movement. Upon E-field polarization, we observed a defibrillation of the different lattice motions.</abstract><cop>United States</cop><pub>American Association for the Advancement of Science</pub><pmid>29051376</pmid><doi>10.1126/science.aal2456</doi><tpages>5</tpages><orcidid>https://orcid.org/0000-0002-5866-1106</orcidid><orcidid>https://orcid.org/0000-0002-8105-2157</orcidid><orcidid>https://orcid.org/0000-0002-5759-1134</orcidid><orcidid>https://orcid.org/0000-0003-2754-5273</orcidid><orcidid>https://orcid.org/0000-0003-0931-085X</orcidid><orcidid>https://orcid.org/0000-0003-2437-9011</orcidid><orcidid>https://orcid.org/0000-0002-1434-095X</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0036-8075
ispartof Science (American Association for the Advancement of Science), 2017-10, Vol.358 (6361), p.347-351
issn 0036-8075
1095-9203
language eng
recordid cdi_proquest_miscellaneous_1954068664
source American Association for the Advancement of Science; JSTOR-E-Journals; Alma/SFX Local Collection
subjects Deformation
Deformation mechanisms
Deoxidizing
Deuterium
Electric fields
Gas mixtures
Gas permeation
Gas transport
Lattices
Membranes
Metal-organic frameworks
Metals
NMR
Nuclear magnetic resonance
Penetration
Polarization
Porosity
Spectroscopy
Stiffening
Switching
X-ray diffraction
title Defibrillation of soft porous metal-organic frameworks with electric fields
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T11%3A16%3A14IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-jstor_proqu&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Defibrillation%20of%20soft%20porous%20metal-organic%20frameworks%20with%20electric%20fields&rft.jtitle=Science%20(American%20Association%20for%20the%20Advancement%20of%20Science)&rft.au=Knebel,%20A.&rft.date=2017-10-20&rft.volume=358&rft.issue=6361&rft.spage=347&rft.epage=351&rft.pages=347-351&rft.issn=0036-8075&rft.eissn=1095-9203&rft_id=info:doi/10.1126/science.aal2456&rft_dat=%3Cjstor_proqu%3E26400567%3C/jstor_proqu%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c425t-2c1734090fd486c1b432f3b6de2d7bc4e12cfde3392d82837ad0d5d882d8e4573%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1975003438&rft_id=info:pmid/29051376&rft_jstor_id=26400567&rfr_iscdi=true