Loading…

Field-usable lateral flow immunoassay for the rapid detection of a macluravirus, large cardamom chirke virus

•The immunostrip was developed for the rapid and cost effective detection of LCCV in field. So far, immunostrip was not developed at commercial level for LCCV detection.•The field-usable sample extraction method was developed and validated.•LCCV detection was done visually within ∼10 min.•The diagno...

Full description

Saved in:
Bibliographic Details
Published in:Journal of virological methods 2018-03, Vol.253, p.43-48
Main Authors: Maheshwari, Yogita, Vijayanandraj, Selvaraj, Jain, Rakesh Kumar, Mandal, Bikash
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:•The immunostrip was developed for the rapid and cost effective detection of LCCV in field. So far, immunostrip was not developed at commercial level for LCCV detection.•The field-usable sample extraction method was developed and validated.•LCCV detection was done visually within ∼10 min.•The diagnostic specificity and sensitivity was 100% and 90% respectively.•The Cohen’s kappa coefficient (0.701) suggested a very good agreement between the ELISA and LFIA. A simple and rapid lateral flow immunoassay (LFIA) was developed by utilizing gold nanoparticles conjugated to a polyclonal antibody against coat protein of large cardamom chirke virus (LCCV). The LFIA based on the principle of sandwich immunoassay detected LCCV within ∼10 min and the result could be evaluated visually. The colloidal gold (CG) was made using 1% gold chloride solution. The LCCV IgG (1 μg/μl) and Mouse IgG (0.5 μg/μl) were conjugated with CG individually and coated onto a conjugate pad at 1:1 ratio. A sample extraction procedure was optimized in order to get adequate clear leaf sap of large cardamom leaf within few minutes. The sensitivity limit of the detection was 1:40 dilution of LCCV infected leaf sap. The diagnostic performance of LFIA was compared with ELISA using field samples. The LFIA was free from false positive as no visible test line was developed with healthy and potyviruses such as papaya ringspot virus and potato virus Y. The diagnostic specificity and sensitivity of LFIA was 100% and 90%, respectively. The Cohen’s kappa coefficient (0.701) suggested a very good agreement between the ELISA and LFIA. Receiver operating characteristic analysis indicated that LFIA was a robust method as the area under the curve (0.950) is significantly (P
ISSN:0166-0934
1879-0984
DOI:10.1016/j.jviromet.2017.12.009