Loading…
Investigating cigarette-smoke indoor pollution in a controlled environment
The objective of this study was to investigate the evolution of pollutant concentrations generated by smoking in a controlled indoor environment. For this purpose, a small flat in the centre of Athens, Greece was equipped with NO x , O 3 and SO 2 continuous measuring instruments and portable analyse...
Saved in:
Published in: | The Science of the total environment 2005-01, Vol.337 (1), p.183-190 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The objective of this study was to investigate the evolution of pollutant concentrations generated by smoking in a controlled indoor environment. For this purpose, a small flat in the centre of Athens, Greece was equipped with NO
x
, O
3 and SO
2 continuous measuring instruments and portable analysers for spot measurements of TVOCs and CO
2, while two volunteer smokers remained inside and smoked as normal inhabitants. The results indicated that when windows are kept closed and smoking takes place NO
x
, CO
2 and TVOCs concentrations increase by an order of 3, 4 or 10 times, respectively, and decrease returning to initial levels after 1 or 2 h. |
---|---|
ISSN: | 0048-9697 1879-1026 |
DOI: | 10.1016/j.scitotenv.2004.06.014 |