Investigating cigarette-smoke indoor pollution in a controlled environment

The objective of this study was to investigate the evolution of pollutant concentrations generated by smoking in a controlled indoor environment. For this purpose, a small flat in the centre of Athens, Greece was equipped with NO x , O 3 and SO 2 continuous measuring instruments and portable analyse...

Full description

Saved in:
Bibliographic Details
Published in:The Science of the total environment 2005-01, Vol.337 (1), p.183-190
Main Authors: Halios, Christoforos H., Assimakopoulos, Vasiliki D., Helmis, Costas G., Flocas, Helena A.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The objective of this study was to investigate the evolution of pollutant concentrations generated by smoking in a controlled indoor environment. For this purpose, a small flat in the centre of Athens, Greece was equipped with NO x , O 3 and SO 2 continuous measuring instruments and portable analysers for spot measurements of TVOCs and CO 2, while two volunteer smokers remained inside and smoked as normal inhabitants. The results indicated that when windows are kept closed and smoking takes place NO x , CO 2 and TVOCs concentrations increase by an order of 3, 4 or 10 times, respectively, and decrease returning to initial levels after 1 or 2 h.
ISSN:0048-9697
1879-1026